In Vivo Stability of Hydroxyapatite Nanoparticles Coated on Titanium Implant Surfaces

被引:1
|
作者
Wennerberg, Ann [1 ,2 ]
Jimbo, Ryo [1 ,2 ]
Allard, Stefan [3 ]
Skarnemark, Gunnar [3 ]
Andersson, Martin [3 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, Malmo, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Gothenburg, Sweden
[3] Chalmers, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
implant; in vivo; nanocoat instability; CALCIUM-PHOSPHATE; OSTEOBLAST ADHESION; ENDOSSEOUS IMPLANTS; BONE-FORMATION; NANO; OSSEOINTEGRATION; CELLS; DOGS; RAT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Nanotechnology has been employed in attempts to enhance bone incorporation of dental implants. Often, nanoparticles are applied to the implant surface as particle coatings. However, the same properties that may increase the functionality may also lead to undiscovered negative effects, such as instability of the nanocoating. The aim of this study was to investigate the stability/instability of the nanoparticles using a radiolabeling technique. Materials and Methods: Twenty threaded and turned titanium microimplants were inserted in 10 rats. All 20 implants were coated with nanometer-sized hydroxyapatite (HA) particles. In order to trace the HA nanoparticles, the particles for 16 implants were labeled with calcium 45 ((45)Ca). After 1, 2, 4, and 8 weeks, the implants and surrounding bone were retrieved and analyzed using autoradiography with respect to particle migration from the implant surface. Samples from the brain, liver, thymus, kidney, and blood, as well as wooden shavings from the rats' cages, were also retrieved and analyzed using liquid scintillation counting. Results: The radioactivity representing the localization of 45Ca decreased over time from the vicinity of the implant. The amounts of 45Ca found in the blood and in the rats' excretions decreased with time and corresponded well to each other. After 8 weeks, the only trace of 45Ca was found in the liver. Conclusion: The results indicated that released particles leave the body through the natural cleaning system, and the probability that the nanocoating will assemble in vital organs and thus become a potential biologic risk factor is unlikely. Int J Oral Maxillofac Implants 2011;26:1161-1166
引用
收藏
页码:1161 / 1166
页数:6
相关论文
共 50 条
  • [21] Effects of hydroxyapatite-coated and commercially pure titanium oral implant surfaces on compound nerve action potentials -: A study on the rat sciatic nerve
    Çehreli, MC
    Onur, MA
    Sahin, S
    CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) : 269 - 272
  • [22] CHARACTERISTICS OF HYDROXYAPATITE COATINGS FOR IMPLANT SURFACES
    BLUMENTHAL, NC
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES ORTHOPAEDIC INSTITUTE, 1991, 51 (01): : 115 - 115
  • [23] Biocompatibility and antibacterial properties of pure titanium surfaces coated with yttrium-doped hydroxyapatite
    Zhang, Kailiang
    Zhang, Baoping
    Huang, Chunjuan
    Gao, Shuting
    Li, Bo
    Cao, Rui
    Cheng, Jingyang
    Li, Ruiping
    Yu, Zhanhai
    Xie, Xiaodong
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 100
  • [24] Electrospun titanium dioxide nanofibers containing hydroxyapatite and silver nanoparticles as future implant materials
    Faheem A. Sheikh
    Nasser A. M. Barakat
    Muzafar A. Kanjwal
    R. Nirmala
    John Hwa Lee
    Hern Kim
    Hak Yong Kim
    Journal of Materials Science: Materials in Medicine, 2010, 21 : 2551 - 2559
  • [25] Electrospun titanium dioxide nanofibers containing hydroxyapatite and silver nanoparticles as future implant materials
    Sheikh, Faheem A.
    Barakat, Nasser A. M.
    Kanjwal, Muzafar A.
    Nirmala, R.
    Lee, John Hwa
    Kim, Hern
    Kim, Hak Yong
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2010, 21 (09) : 2551 - 2559
  • [26] Discrete deposition of hydroxyapatite nanoparticles on a titanium implant with predisposing substrate microtopography accelerated osseointegration
    Nishimura, Ichiro
    Huang, Yuhong
    Butz, Frank
    Ogawa, Takahiro
    Lin, Audrey
    Wang, Chiachien Jake
    NANOTECHNOLOGY, 2007, 18 (24)
  • [27] Effect of implant curets on titanium implant surfaces
    CrossPoline, GN
    Shaklee, RL
    Stach, DJ
    AMERICAN JOURNAL OF DENTISTRY, 1997, 10 (01): : 41 - 45
  • [28] Titanium dental implant surfaces
    Elias, Carlos Nelson
    MATERIA-RIO DE JANEIRO, 2010, 15 (02): : 140 - 144
  • [29] Comparison of seriousness of periimplantitis around hydroxyapatite implant and titanium implant
    Kanematsu, N
    Sai, T
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 839 - 839
  • [30] The Soft Tissue Immunologic Response to Hydroxyapatite-Coated Transmucosal Implant Surfaces: A Study in Humans
    De Wilde, Elisabeth A. W. J.
    Jimbo, Ryo
    Wennerberg, Ann
    Naito, Yoshihito
    Coucke, Paul
    Bryington, Matthew S.
    Vandeweghe, Stefan
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E65 - E74