A VI-based measurement system for sharing the customer and supply responsibility for harmonic distortion

被引:0
|
作者
Sasdelli, R [1 ]
Muscas, C [1 ]
Peretto, L [1 ]
机构
[1] Univ Bologna, Dipartimento Ingn Elettr, Bologna, Italy
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The current and the voltage distortion in public distribution systems is ever increasing because of the proliferation of nonlinear and time-varying loads. Online investigation methods are searched for, which should be capable of providing information about the responsibility for harmonic distortion in a given metering section. Some recently proposed investigation methods are recalled and the relevant measurement problems are discussed. A digital measurement system which is based on the Virtual instrumentation (VI) technique and implements these methods, is described. The results of some experimental work are also presented.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [21] A Robust Wavelet-Based Hybrid Method for the Simultaneous Measurement of Harmonic and Supraharmonic Distortion
    Lodetti, Stefano
    Bruna, Jorge
    Melero, Julio J.
    Khokhlov, Victor
    Meyer, Jan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 6704 - 6712
  • [22] Automatic measurement system of harmonic based on virtual instrument
    Liu, Jinqing
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (SUPP. 4): : 215 - 216
  • [23] Total harmonic distortion measurement system of electronic devices up to 100 MHz with remarkable sensitivity
    Komuro, Takanori
    Sobukawa, Shingo
    Sakayori, Hiroshi
    Kono, Masashi
    Kobayashi, Haruo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2360 - 2368
  • [24] Minimizing Total Harmonic Distortion in a Multi-level based WPT System
    Rahnamaee, Hamid Reza
    Madawala, Udaya K.
    Thrimawithana, Duleepa J.
    2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, : 696 - 701
  • [25] Measurement of harmonic impedance on an LV system utilising power capacitor switching and consequent predictions of capacitor induced harmonic distortion.
    Bridgeman, MJ
    Morrison, RE
    Tenakoon, SB
    8TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, PROCEEDINGS, VOLS 1 AND 2, 1998, : 1141 - 1145
  • [26] Information sharing System for Logistics Service Supply Chains based on XML
    Wang, Zhihong
    Liu, Yong
    2014 11TH INTERNATIONAL CONFERENCE ON SERVICE SYSTEMS AND SERVICE MANAGEMENT (ICSSSM), 2014,
  • [27] Knowledge sharing system based on semantic web technology in supply chain
    School of Management, Fudan University, Shanghai 200433, China
    Xitong Gongcheng Lilum yu Shijian, 2007, 12 (96-103):
  • [28] AHP based supply chain performance measurement system
    Xia, Laura Xu Xiao
    Bin, M. A.
    Roland, Lim
    ETFA 2007: 12TH IEEE INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION, VOLS 1-3, 2007, : 1308 - +
  • [29] Electromagnetic Interference Analysis Based on Total Harmonic Distortion Measurement in 900 MHz Cordless Telephones
    Park, Jeung Geun
    Kim, Che Young
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2010, E93B (09) : 2348 - 2353
  • [30] Construction of the Automatic Measurement System of Electromagnetism Radiation Based on VI
    Zheng Qingyang
    Hao Guiyou
    Xia Kehan
    Cheng Jie
    Yang Xiaogang
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2276 - 2279