Electromagnetic Interference Analysis Based on Total Harmonic Distortion Measurement in 900 MHz Cordless Telephones

被引:0
|
作者
Park, Jeung Geun [1 ]
Kim, Che Young [1 ]
机构
[1] Kyungpook Natl Univ, Sch Elect Engn, Taegu 702701, South Korea
关键词
total harmonic distortion; electromagnetic intelference; cordless telephone (CT-l); low power radio device; THD measurement;
D O I
10.1587/transcom.E93.B.2348
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a new electromagnetic (EM) interference analysis is proposed using the total harmonic distortion (THD) measurement of the audio signal by the 900 MHz cordless telephones. The cordless telephone network in 900 MHz was built up to be weak in EM interference. 400 and 800 Hz of the sine-wave signal were used in transmitter (TX) system, and the receiver (RX) system was exposed to the EM interference. The THD value varies as the level of the exposed EM interference changes. The model of the cordless telephone also affects the THD value. By using fluctuation of the THD value depending on the amount of the exposure, the threshold value of the interference electric field strength was derived. Based on the derived threshold value of the electric field strength, validity of the regulation value for low power radio devices by CISPR 22 [CLASS B] and FCC is discussed.
引用
收藏
页码:2348 / 2353
页数:6
相关论文
共 50 条
  • [1] RADIO PROPAGATION FOR DIGITAL CORDLESS TELEPHONES AT 1700 MHZ AND 900 MHZ
    OWEN, FC
    PUDNEY, CD
    ELECTRONICS LETTERS, 1989, 25 (01) : 52 - 53
  • [2] IN-BUILDING PROPAGATION AT 900 MHZ AND 1650 MHZ FOR DIGITAL CORDLESS TELEPHONES
    OWEN, FC
    PUDNEY, CD
    SIXTH INTERNATIONAL CONFERENCE ON ANTENNAS AND PROPAGATION ( ICAP 89 ), PARTS 1-2, 1989, 301 : B276 - B280
  • [3] Analysis of harmonic distortion and electromagnetic interference due to electronic and electromagnetic ballasts
    Nyland, F
    Schlichting, LCM
    Liz, MB
    Raizer, A
    10TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER, VOLS I AND II, PROCEEDINGS, 2002, : 765 - 769
  • [4] Total harmonic distortion measurement system of electronic devices up to 100 MHz with remarkable sensitivity
    Komuro, Takanori
    Sobukawa, Shingo
    Sakayori, Hiroshi
    Kono, Masashi
    Kobayashi, Haruo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2360 - 2368
  • [5] Potentialities of total harmonic distortion measurement techniques
    Naviius, A
    Knyva, V
    BEC 2004: Proceeding of the 9th Biennial Baltic Electronics Conference, 2004, : 187 - 188
  • [6] Total harmonic distortion analysis simulation
    Abbas, MH
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1631 - 1634
  • [7] Measurement uncertainty in evaluating total harmonic distortion factor
    De Capua, C
    Landi, C
    Malafronte, GC
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 675 - 679
  • [8] Interference analysis of a total frequency hopping GSM cordless telephony system
    Deissner, J
    Barreto, AN
    Barth, U
    Fettweis, G
    NINTH IEEE INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, VOLS 1-3, 1998, : 1525 - 1529
  • [9] Total Harmonic Distortion Analysis in Magnetic Characterization using High Frequency GaN Inverter in the MHz Order
    Martinez, Wilmar
    Suarez, Camilo
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,