Spectral analysis of scattered radiation in CT

被引:8
|
作者
Engel, Klaus J. [1 ]
Baeumer, Christian [1 ]
Wiegert, Jens [1 ]
Zeitler, Guenter [1 ]
机构
[1] Philips Res Europe, D-52066 Aachen, Germany
关键词
Computed Tomography; Spectral CT; X-ray radiation; scatter spectrum; spectral composition; scatter-to-primary ratio; anti-scatter grids; single and multiple scattered X-rays;
D O I
10.1117/12.771063
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the framework of Spectral Computed Tomography (Spectral CT), scattered X-ray radiation is examined for its spectral composition and spatial distribution by means of Monte Carlo simulations. A reliable material (e.g. bone / contrast agent) separation and quantification requires a precise knowledge of the transmitted X-ray spectrum especially for low energy photons. Unfortunately, for lower energies the primary intensity is increasingly covered by scattered radiation. The detected scattered radiation can be classified into two main categories with respect to their scattering history. The first category contains purely Rayleigh or one-time Compton scattered photons which typically have small scattering angles and an energy spectrum similar to that of the transmitted primary radiation. The second category comprises multiple Compton scattered photons with a spectral composition which is typically softer than that of the transmitted primary photons. In regions of strong beam attenuation (i.e. in the X-ray shadow of a scanned object), the scattered radiation is mainly composed of multiple Compton scattered photons. As a consequence, the spectrally resolved scatter-to-primary ratios strongly increase at low energies. High-quality anti-scatter grids can be used to reduce especially the detection of multiple Compton-scattered photons. A quantitative evaluation of measured photon energies below a certain limit between 30 keV and 50 keV (depending on the phantom geometry and the applied anti-scatter grid) is challenging, since primary photons are superposed by a significantly higher amount of scattered photons.
引用
收藏
页码:R9131 / R9131
页数:11
相关论文
共 50 条
  • [41] SPECTRAL ANALYSIS BY CORRELATION OF ULTRASONIC WAVE SCATTERED BY AGITATED SURFACE
    GAZANHES, C
    LEANDRE, J
    ACUSTICA, 1971, 25 (03): : 186 - &
  • [42] SPECTRAL ANALYSIS OF LASER LIGHT SCATTERED FROM MOTILE MICROORGANISMS
    NOSSAL, R
    BIOPHYSICAL JOURNAL, 1971, 11 (04) : 341 - &
  • [44] THE INFLUENCE OF SCATTERED RADIATION ON THE CT NUMBERS OF BONE ON A SCANNER WITH A FIXED DETECTOR ARRAY
    MORAN, PR
    KWA, WSY
    CHENERY, SAG
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (08): : 939 - 951
  • [45] Truncation Correction for VOI C-arm CT using Scattered Radiation
    Bier, Bastian
    Maier, Andreas
    Hofmann, Hannes G.
    Schwemmer, Chris
    Xia, Yan
    Struffert, Tobias
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [46] Spectral measurements of direct and scattered gamma radiation at a boiling-water reactor site
    1600, Publ by Elsevier Science Publ BV (North-Holland), Amsterdam, Neth (299): : 1 - 3
  • [47] SPECTRAL FLUENCE OF SCATTERED RADIATION IN A WATER MEDIUM IRRADIATED WITH DIAGNOSTIC X-RAYS
    EPP, ER
    WEISS, H
    RADIATION RESEARCH, 1967, 30 (01) : 129 - &
  • [48] Simulation of Spectral and Angular Brightness Characteristics of the Scattered Radiation of Clouds in the Visible and Infrared Bands
    Repin, VG
    Lagutkin, VN
    Luk'yanov, AP
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2001, 46 (10) : 1142 - 1148
  • [49] Radiation dose reduction in parasinus CT by spectral shaping
    May, Matthias S.
    Brand, Michael
    Lell, Michael M.
    Sedlmair, Martin
    Allmendinger, Thomas
    Uder, Michael
    Wuest, Wolfgang
    NEURORADIOLOGY, 2017, 59 (02) : 169 - 176
  • [50] Image Noise and Radiation Dose Reduction in Spectral CT
    Leng, S.
    McCollough, C.
    Fletcher, J.
    Yu, L.
    Mistretta, C.
    MEDICAL PHYSICS, 2010, 37 (06) : 3408 - +