Image Noise and Radiation Dose Reduction in Spectral CT

被引:1
|
作者
Leng, S.
McCollough, C.
Fletcher, J.
Yu, L.
Mistretta, C.
机构
关键词
D O I
10.1118/1.3469317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-E201B07
引用
收藏
页码:3408 / +
页数:2
相关论文
共 50 条
  • [1] Radiation dose reduction in parasinus CT by spectral shaping
    May, Matthias S.
    Brand, Michael
    Lell, Michael M.
    Sedlmair, Martin
    Allmendinger, Thomas
    Uder, Michael
    Wuest, Wolfgang
    NEURORADIOLOGY, 2017, 59 (02) : 169 - 176
  • [2] Radiation dose reduction in parasinus CT by spectral shaping
    Matthias S May
    Michael Brand
    Michael M Lell
    Martin Sedlmair
    Thomas Allmendinger
    Michael Uder
    Wolfgang Wuest
    Neuroradiology, 2017, 59 : 169 - 176
  • [3] Radiation dose reduction in CT of the brain: can advanced noise filtering compensate for loss of image quality?
    Siemund, Roger
    Love, A.
    van Westen, D.
    Stenberg, L.
    Petersen, C.
    Bjorkman-Burtscher, I. M.
    ACTA RADIOLOGICA, 2012, 53 (04) : 468 - 472
  • [4] Noise reduction in spectral CT: Reducing dose and breaking the trade-off between image noise and energy bin selection
    Leng, Shuai
    Yu, Lifeng
    Wang, Jia
    Fletcher, Joel G.
    Mistretta, Charles A.
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2011, 38 (09) : 4946 - 4957
  • [5] Image optimization and reduction of radiation dose in CT of the paranasal sinuses
    Davoudi, Mohammad
    Lotfian Ahangarkolaei, Shaghayegh
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [6] CT image denoising methods for image quality improvement and radiation dose reduction
    Sadia, Rabeya Tus
    Chen, Jin
    Zhang, Jie
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [7] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Massimo Cristofaro
    Elisa Busi Rizzi
    Pierluca Piselli
    Elisa Pianura
    Ada Petrone
    Nicoletta Fusco
    Federica Di Stefano
    Vincenzo Schinina’
    La radiologia medica, 2020, 125 : 451 - 460
  • [8] Image quality and radiation dose reduction in chest CT in pulmonary infection
    Cristofaro, Massimo
    Rizzi, Elisa Busi
    Piselli, Pierluca
    Pianura, Elisa
    Petrone, Ada
    Fusco, Nicoletta
    Di Stefano, Federica
    Schinina', Vincenzo
    RADIOLOGIA MEDICA, 2020, 125 (05): : 451 - 460
  • [9] Reduction of radiation dose in PET-CT: Low dose protocols and image quality
    Kim, Hyeon Sik
    Sheen, Heesoon
    Jung, Sung Pil
    Hong, Seon Pyo
    Byun, Byung-Hyun
    Min, Jung-Joon
    Lee, Byeong-il
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [10] Deep Convolutional approach for Low-Dose CT Image Noise Reduction
    Badretale, Seyyedomid
    Shaker, Fariba
    Babyn, Paul
    Alirezaie, Javad
    2017 24TH NATIONAL AND 2ND INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING (ICBME), 2017, : 142 - 146