Isotope fractionation during capillary leaking in an isotope ratio mass spectrometer

被引:4
|
作者
Yan, Hao [1 ,2 ]
Peng, Yongbo [1 ,2 ]
Bao, Huiming [1 ,2 ]
机构
[1] Nanjing Univ, Int Ctr Isotope Effects Res, Nanjing, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
GAS-FLOWS; OXYGEN; O-18/O-16; O-17/O-16;
D O I
10.1002/rcm.9290
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale When isotope composition is measured in dual-inlet mode with an isotope ratio mass spectrometer (IRMS), reference gas may be gradually enriched in heavy isotopes due to preferential loss of light ones from the bellows over time. Quantifying the degree of isotopic enrichment of the reference gas is imperative for high-precision isotopic analysis (i.e. at per meg level). Methods O-2 and CO2 leaking experiments were performed with the dual-inlet system of an IRMS (Thermo Fisher (R) MAT 253 Plus). During each experiment, the drop of gas pressure in the bellows with time was recorded and isotope ratios of residual gas at various time intervals were analyzed. Results Isotopic enrichment of residual O-2 gas could be as large as 1 parts per thousand for delta O-18 when a large fraction (>75%) of initial gas was lost. The evolution of isotope compositions of the remaining gas can be well described by a pressure-dependent Rayleigh fractionation equation. When the pressure in the bellows is within 10-50 mBar, the isotope fractionation factor (alpha O-18) for O-2 leaking ranges from 0.99911 to 0.99982 and the characteristic relationship of alpha O-17 and alpha O-18 is from 0.5123 to 0.5124. Conclusions Isotope fractionation associated with capillary leaking from bellows is pressure-dependent. We recommend that the reference gas should be reloaded frequently, especially after a measurement with a low analyzing pressure for the analysis of small amounts of sample.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Progress on the HVEE 14C isotope ratio mass spectrometer for biomedical applications
    Mous, DJW
    Fokker, W
    van den Broek, R
    Koopmans, R
    Ramsey, CB
    Hedges, REM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 136 : 1052 - 1056
  • [42] Evaluation of the isotope ratio performance of an axial time-of-flight ICP mass spectrometer
    Vanhaecke, F
    Moens, L
    Dams, R
    Allen, L
    Georgitis, S
    ANALYTICAL CHEMISTRY, 1999, 71 (15) : 3297 - 3303
  • [43] Progress on the HVEE 14C isotope ratio mass spectrometer for biomedical applications
    Mous, D.J.W.
    Fokker, W.
    van den Broek, R.
    Koopmans, R.
    Ramsey, C.Bronk
    Hedges, R.E.M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1998, 136-138 : 1052 - 1056
  • [44] Mass spectrometer for routine isotope and gas analyses
    不详
    JOURNAL OF APPLIED PHYSICS, 1940, 11 (10) : 628 - 629
  • [45] A MASS SPECTROMETER FOR ISOTOPE ANALYSIS OF THE ALKALI METALS
    REUTERSWARD, C
    ARKIV FOR FYSIK, 1950, 1 (06): : 545 - 546
  • [46] Design of a Miniature Space Isotope Mass Spectrometer
    Wang X.-Z.
    Sun J.
    Yang Z.
    Li G.
    Su H.-B.
    Tan G.-B.
    Gao W.
    Journal of Chinese Mass Spectrometry Society, 2023, 44 (03) : 357 - 366
  • [47] A MASS SPECTROMETER AND THE MEASUREMENT OF ISOTOPE EXCHANGE FACTORS
    THODE, HG
    GRAHAM, RL
    ZIEGLER, JA
    CANADIAN JOURNAL OF RESEARCH SECTION B-CHEMICAL SCIENCES, 1945, 23 (01): : 40 - 47
  • [48] Design and development of a compact thermal ionization mass spectrometer for isotope ratio measurement of uranium
    Bhatia, Rajender Kumar
    Yadav, Varun Kant
    Gulhane, Milind Manoharrao
    Datta, Rabi
    Joshi, Kuldip Devidas
    Kasbekar, Ajay Mahadeo
    Das, Subrata
    Sreeramulu, Konjeti
    Saha, Tushar Kanti
    Ravisankar, Edakkunni
    Nataraju, Vogirala
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (03)
  • [49] AUTOMATIC INLET SYSTEM WITH PNEUMATIC CHANGEOVER VALVES FOR ISOTOPE RATIO MASS-SPECTROMETER
    HALAS, S
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1979, 12 (05): : 418 - 420
  • [50] RECONSTRUCTION OF ISOTOPE MASS SPECTROMETER FOR CHEMICAL INVESTIGATIONS
    EFREMOV, YY
    BIKBULAT.TA
    TEITELBAUM, BY
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (JUN) : 1187 - &