Isotope fractionation during capillary leaking in an isotope ratio mass spectrometer

被引:4
|
作者
Yan, Hao [1 ,2 ]
Peng, Yongbo [1 ,2 ]
Bao, Huiming [1 ,2 ]
机构
[1] Nanjing Univ, Int Ctr Isotope Effects Res, Nanjing, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
GAS-FLOWS; OXYGEN; O-18/O-16; O-17/O-16;
D O I
10.1002/rcm.9290
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale When isotope composition is measured in dual-inlet mode with an isotope ratio mass spectrometer (IRMS), reference gas may be gradually enriched in heavy isotopes due to preferential loss of light ones from the bellows over time. Quantifying the degree of isotopic enrichment of the reference gas is imperative for high-precision isotopic analysis (i.e. at per meg level). Methods O-2 and CO2 leaking experiments were performed with the dual-inlet system of an IRMS (Thermo Fisher (R) MAT 253 Plus). During each experiment, the drop of gas pressure in the bellows with time was recorded and isotope ratios of residual gas at various time intervals were analyzed. Results Isotopic enrichment of residual O-2 gas could be as large as 1 parts per thousand for delta O-18 when a large fraction (>75%) of initial gas was lost. The evolution of isotope compositions of the remaining gas can be well described by a pressure-dependent Rayleigh fractionation equation. When the pressure in the bellows is within 10-50 mBar, the isotope fractionation factor (alpha O-18) for O-2 leaking ranges from 0.99911 to 0.99982 and the characteristic relationship of alpha O-17 and alpha O-18 is from 0.5123 to 0.5124. Conclusions Isotope fractionation associated with capillary leaking from bellows is pressure-dependent. We recommend that the reference gas should be reloaded frequently, especially after a measurement with a low analyzing pressure for the analysis of small amounts of sample.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] COMPUTER-CONTROLLED ION COUNTING ISOTOPE RATIO MASS-SPECTROMETER
    SCHOELLER, DA
    HAYES, JM
    ANALYTICAL CHEMISTRY, 1975, 47 (03) : 408 - 415
  • [22] AUTOMATION OF AN INTERFACE BETWEEN A NITROGEN ANALYZER AND AN ISOTOPE RATIO MASS-SPECTROMETER
    MARSHALL, RB
    WHITEWAY, JN
    ANALYST, 1985, 110 (07) : 867 - 871
  • [23] A new gas inlet system for an isotope ratio mass spectrometer improves reproducibility
    Leuenberger, M
    Nyfeler, P
    Moret, HP
    Sturm, P
    Huber, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (16) : 1543 - 1551
  • [24] A compact C-14 Isotope Ratio Mass Spectrometer for biomedical applications
    Mous, DJW
    Purser, KH
    Fokker, W
    vandenBroek, R
    Koopmans, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 123 (1-4): : 159 - 162
  • [25] Determination of nitrogen isotopomers of nitrous oxide on a modified isotope ratio mass spectrometer
    Toyoda, S
    Yoshida, N
    ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4711 - 4718
  • [26] Isotope ratio dual-comb spectrometer
    Parriaux, Alexandre
    Hammani, Kamal
    Thomazo, Christophe
    Musset, Olivier
    Millot, Guy
    PHYSICAL REVIEW RESEARCH, 2022, 4 (02):
  • [27] Determination of the mass-dependence of cadmium isotope fractionation during evaporation
    Wombacher, F
    Rehkämper, M
    Mezger, K
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (10) : 2349 - 2357
  • [28] Observations of Si isotope mass fractionation during freshwater diatom blooms
    Reynolds, BC
    Jaccard, SL
    Lehmann, MF
    Bernasconi, SM
    Frank, M
    Halliday, A
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A212 - A212
  • [29] MASS INDEPENDENT ISOTOPE FRACTIONATION OF MOLECULAR OXYGEN DURING ELECTRON IONIZATION
    Abe, O.
    Ozima, M.
    Yamada, A.
    METEORITICS & PLANETARY SCIENCE, 2009, 44 : A15 - A15
  • [30] Pb isotope fractionation during evaporation
    Zhu, X. K.
    Wu, X. H.
    Cui, J. F.
    Yang, C.
    Yang, Y. L.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A754 - A754