Multifrequency Magnetic Resonance Elastography for the Assessment of Renal Allograft Function

被引:41
|
作者
Garcia, Stephan Rodrigo Marticorena [1 ]
Fischer, Thomas [1 ]
Duerr, Michael [2 ]
Gueltekin, Emin [1 ]
Braun, Juergen [3 ]
Sack, Ingolf [1 ]
Guo, Jing [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Berlin, Germany
[2] Charite Univ Med Berlin, Dept Nephrol, Berlin, Germany
[3] Charite Univ Med Berlin, Dept Med Informat, Berlin, Germany
关键词
multifrequency magnetic resonance elastography; kidney; renal allograft; shear waves; renal stiffness; renal dysfunction; MR ELASTOGRAPHY; TRANSIENT ELASTOGRAPHY; TISSUE ELASTICITY; KIDNEY; STIFFNESS; FIBROSIS; FEASIBILITY; DIAGNOSIS; HISTOLOGY; BIOPSY;
D O I
10.1097/RLI.0000000000000271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to apply multifrequency magnetic resonance elastography (MMRE) for assessment of kidney function based on renal stiffness of allografts in transplant recipients and native kidneys in controls. Methods: In this prospective study, MMRE was used to measure stiffness in transplant kidneys in 22 recipients (age range, 23-73 years; 7 females) and in native kidneys in 11 controls (age range, 26-55 years; 4 females) after internal review board approval. TheMMREwas performed on a 1.5 Tmagnetic resonance imaging scanner using 4 vibration frequencies from 40 to 70 Hz. Stiffness maps were computed by multifrequency reconstruction of the magnitude shear modulus (vertical bar G*vertical bar). Clinical markers such as glomerular filtration rate (GFR) and resistive index (RI) were acquired. Differences in renal stiffness among groups were compared by Mann-Whitney U test. Correlations were tested using Pearson correlation. Results: Functioning transplants had higher stiffness (vertical bar G*vertical bar = 9.00 +/- 1.71 kPa) than nonfunctioning transplants (vertical bar G*vertical bar = 5.88 +/- 1.71 kPa, P < 0.001) and native kidneys (vertical bar G*vertical bar = 6.63 +/- 1.63 kPa, P < 0.01). A cutoff value of 7.04 kPa provided sensitivity (83.33%) and specificity (86.67%) for detecting renal allograft dysfunction with an area under the receiver operating characteristic curve value of 0.9278 (95% confidence interval, 0.83-1.00). vertical bar G*vertical bar correlated positively with GFR (r = 0.52, P = 0.015) and negatively with RI (r = -0.52, P = 0.016). Conclusions: Multifrequency magnetic resonance elastography has good diagnostic accuracy in detecting renal allograft dysfunction. Renal stiffness is significantly lower in recipients with nonfunctioning transplant kidneys and correlates with clinical markers such as GFR and RI.
引用
收藏
页码:591 / 595
页数:5
相关论文
共 50 条
  • [21] Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography
    Klatt, Dieter
    Friedrich, Christian
    Korth, Yasmin
    Vogt, Robert
    Braun, Juergen
    Sack, Ingolf
    BIORHEOLOGY, 2010, 47 (02) : 133 - 141
  • [22] FE Modeling of Living Human Brain Using Multifrequency Magnetic Resonance Elastography
    Naeeni, Hamed Ajabi
    Haghpanahi, Mohammad
    MECHANICAL, MATERIALS AND MANUFACTURING ENGINEERING, PTS 1-3, 2011, 66-68 : 384 - +
  • [23] High-Resolution Mechanical Imaging of Glioblastoma by Multifrequency Magnetic Resonance Elastography
    Streitberger, Kaspar-Josche
    Reiss-Zimmermann, Martin
    Freimann, Florian Baptist
    Bayerl, Simon
    Guo, Jing
    Arlt, Felix
    Wuerfel, Jens
    Braun, Juergen
    Hoffmann, Karl-Titus
    Sack, Ingolf
    PLOS ONE, 2014, 9 (10):
  • [24] Assessment of hepatic fibrosis with magnetic resonance elastography
    Yin, Meng
    Talwalkar, Jayant A.
    Glaser, Kevin J.
    Manduca, Armando
    Grimm, Roger C.
    Rossman, Phillip J.
    Fidler, Jeff L.
    Ehman, Richard L.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2007, 5 (10) : 1207 - 1213
  • [25] 3D multifrequency magnetic resonance elastography in distinguishing endometrial and cervical adenocarcinoma
    Long, Ling
    Liu, Meiling
    Deng, Xijia
    Cao, Meimei
    Zhang, Jing
    Lan, Xiaosong
    Zhang, Jiuquan
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 62 - 68
  • [26] I am pleased to submitted the letter to the editor entitled "Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction" by Kennedy et al
    Rueda, Maria Alejandra
    Vasquez, Ricardo
    Valencia, Sergio.
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [27] Multifrequency magnetic resonance elastography of the brain reveals tissue degeneration in neuromyelitis optica spectrum disorder
    Kaspar-Josche Streitberger
    Andreas Fehlner
    Florence Pache
    Anna Lacheta
    Sebastian Papazoglou
    Judith Bellmann-Strobl
    Klemens Ruprecht
    Alexander Brandt
    Jürgen Braun
    Ingolf Sack
    Friedemann Paul
    Jens Wuerfel
    European Radiology, 2017, 27 : 2206 - 2215
  • [28] Multifrequency magnetic resonance elastography of the brain reveals tissue degeneration in neuromyelitis optica spectrum disorder
    Streitberger, Kaspar-Josche
    Fehlner, Andreas
    Pache, Florence
    Lacheta, Anna
    Papazoglou, Sebastian
    Bellmann-Strobl, Judith
    Ruprecht, Klemens
    Brandt, Alexander
    Braun, Juergen
    Sack, Ingolf
    Paul, Friedemann
    Wuerfel, Jens
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 2206 - 2215
  • [29] Multifrequency Magnetic Resonance Elastography Detects Small Abdominal Lymph Node Metastasis by High Stiffness
    Neelsen, Christian
    Elgeti, Thomas
    Meyer, Tom
    Grittner, Ulrike
    Moedl, Lukas
    Furth, Christian
    Geisel, Dominik
    Hamm, Bernd
    Sack, Ingolf
    Garcia, Stephan Rodrigo Marticorena
    INVESTIGATIVE RADIOLOGY, 2024, 59 (11) : 787 - 793
  • [30] Heterogeneous Multifrequency Direct Inversion (HMDI) for magnetic resonance elastography with application to a clinical brain exam
    Barnhill, Eric
    Davies, Penny J.
    Ariyurek, Cemre
    Fehlner, Andreas
    Braun, Juergen
    Sack, Ingolf
    MEDICAL IMAGE ANALYSIS, 2018, 46 : 180 - 188