High throughput log D determination using liquid chromatography-mass spectrometry

被引:0
|
作者
Wilson, DM [1 ]
Wang, XL [1 ]
Walsh, E [1 ]
Rourick, RA [1 ]
机构
[1] DuPont Pharmaceut Res Labs, San Diego, CA 92121 USA
关键词
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method has been developed which allows direct measurement of partition coefficients (log D, log P) using liquid chromatography-mass spectrometry (LC-MS). The high throughput, microtiter plate based protocol uses small quantities of 10 mM analyte in DMSO solution (5 muL) and is therefore amenable to standard archive and screening formats. Single Ion Monitoring (SIM) mass spectrometry is used to achieve optimal sensitivity. Experimental log D values for 34 known drugs have been determined, with partition coefficients ranging from -2 to 5, giving data very similar to literature values. In these analyses, deviations from known values average less than 0.3 log units. The sample handling and data processing have been significantly automated, and the protocol has been applied to over 800 in-house lead molecules to date. In its format, sensitivity, throughput, and amenability to automation, it represents significant progress in the direct measurement of partitioning behavior [1].
引用
收藏
页码:511 / 519
页数:9
相关论文
共 50 条
  • [21] Determination of Penicillium mycotoxins in foods and feeds using liquid chromatography-mass spectrometry
    Rundberget, T
    Wilkins, AL
    JOURNAL OF CHROMATOGRAPHY A, 2002, 964 (1-2) : 189 - 197
  • [22] Determination of amino acid isotope enrichment using liquid chromatography-mass spectrometry
    van Eijk, HMH
    Rooyakkers, DR
    Soeters, PB
    Deutz, NEP
    ANALYTICAL BIOCHEMISTRY, 1999, 271 (01) : 8 - 17
  • [23] Determination of deoxynivalenol in cereal grains by high performance liquid chromatography and verified by high performance liquid chromatography-mass spectrometry
    Sui, K
    Li, J
    Wei, F
    Zhao, SC
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (11) : 1643 - 1646
  • [24] Steroid profiling by gas chromatography-mass spectrometry and high performance liquid chromatography-mass spectrometry for adrenal diseases
    McDonald J.G.
    Matthew S.
    Auchus R.J.
    Hormones and Cancer, 2011, 2 (6): : 324 - 332
  • [25] Determination of metabolites of Geotrichum citri-aurantii treated with peppermint oil using liquid chromatography-mass spectrometry and gas chromatography-mass spectrometry
    Qi, Jianrui
    Pang, Yaxing
    An, Peipei
    Jiang, Guoshan
    Kong, Qingjun
    Ren, Xueyan
    JOURNAL OF FOOD BIOCHEMISTRY, 2019, 43 (03)
  • [26] Progress in liquid chromatography-mass spectrometry instrumentation and its impact on high-throughput screening
    Niessen, WMA
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 413 - 436
  • [27] Chiral liquid chromatography-mass spectrometry for high-throughput screening of enzymatic racemase activity
    Henderickx, HJW
    Duchateau, ALL
    Raemakers-Franken, PC
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 69 - 74
  • [28] High-speed simultaneous determination of nine antiepileptic drugs using liquid chromatography-mass spectrometry
    Subramanian, Murali
    Birnbaum, Angela K.
    Remmel, Rory P.
    THERAPEUTIC DRUG MONITORING, 2008, 30 (03) : 347 - 356
  • [29] Determination of perhexiline and hydroxyperhexiline in plasma by liquid chromatography-mass spectrometry
    Beck, O
    Stephanson, N
    Morris, RG
    Sallustio, BC
    Hjemdahl, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 87 - 91
  • [30] Determination of chloramphenicol residues in shrimps by liquid chromatography-mass spectrometry
    Ramos, M
    Muñoz, P
    Aranda, A
    Rodriguez, I
    Diaz, R
    Blanca, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 31 - 38