Development and validation of novel RP-HPLC method for midostaurin determination using analytical quality by design approach from regulatory perspective and determination of major degradation compounds of midostaurin using LC-MS

被引:17
|
作者
Saddala, Madhu Prakash Reddy [1 ]
Konduru, Naresh [2 ]
Gundla, Rambabu [1 ]
Kowtharapu, Leela Prasad [3 ]
机构
[1] GITAM Deemed Univ Hyderabad, Sch Sci, Dept Chem, Sangareddy 502329, India
[2] Zhuhai Resproly Pharmaceut Technol Co Ltd, Analyt Res & Dev, Zhuhai City, Peoples R China
[3] WUXI STA Wuxi App Tec Co Pharmaceut Co Ltd, Analyt Dev, Wuxi, Jiangsu, Peoples R China
关键词
analytical quality by design approach; degradation impurities; LC-MS technique; midostaurin; stability-indicating method; KINASE INHIBITOR;
D O I
10.1002/bmc.5486
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Midostaurin (MTN), designated as an orphan medicinal product, is emerging as an important drug for treating acute myeloid leukemia and advanced systematic mastocytosis. The proposed method was developed and validated to evaluate the related impurities of MTN. The impurities were separated using a YMC Trait C18 ExRS column (150 x 4.6 mm, 3 mu m). Mobile phase A consisted of a 10-mM concentration of phosphate buffer adjusted to pH 3.0 with diluted orthophosphoric acid, and mobile phase B consisted of 90% acetonitrile and 10% water. The optimized chromatographic conditions were as follows: flow rate, 0.5 mL min(-1); injection volume, 10 mu L; UV detection, 290 nm; and linear gradient program, up to 65 min. The method was developed using an analytical quality by design approach. A systematic flow chart shows the evaluation, control, and life cycle management method. As part of method evaluation, risk assessment was conducted. The method has been validated per current guidelines of the International Conference on Harmonization. The recovery study and linearity ranges were established from the limit of quantification to 150% optimal concentrations. The recovery was found to be between 95.5 and 102.5%, and linearity (r(2)) was 0.9998-0.9999 for all the identified impurities. The method precision results were achieved below 10% of relative standard deviation. Forced degradation studies were performed under chemical and physical stress conditions. The compound was sensitive to chemical stress conditions. During the study, the analyte degraded and was converted into the identified degradation impurities, and its molecular mass was found using the LC-MS technique.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Quality by Design-Assisted RP-HPLC Method for Determination of Ritonavir and Darunavir in Pharmaceutical Formulation Using Central Composite Design
    Koppisetty, Bhagavan Rajesh Babu
    Kollabathula, Varaprasada Rao
    Challa, Gangu Naidu
    Yarraguntla, Srinivasa Rao
    SEPARATION SCIENCE PLUS, 2024, 7 (10):
  • [42] Development and validation of analytical method for acidic pesticide residues determination in water using LC-MS/MS: a one year surveillance program for two Egyptian governorates
    Abo-Gaida, Abd-Alrahman H.
    El-Sawi, Sanaa A. M.
    Barakat, Dalia Ahmed
    Hassan, Rodina A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 104 (17) : 4963 - 4976
  • [43] Analytical Method Validation and Determination of Free Drug Content of 4-n-Butylresorcinol in Complex Lipid Nanoparticles Using RP-HPLC Method
    Dwiastuti, Rini
    Marchaban
    Istyastono, Enade Perdana
    Riswanto, Florentinus Dika Octa
    INDONESIAN JOURNAL OF CHEMISTRY, 2018, 18 (03) : 496 - 502
  • [44] Development and robust optimization of the RP-HPLC method for the determination of riociguat and its four impurities in tablets using the AQbD approach
    Rmandic, Milena
    Rasevic, Marija
    Stankovic, Jelena
    Zecevic, Mira
    Otasevic, Biljana
    Protic, Ana
    Malenovic, Andelija
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 258
  • [45] Development and Validation of Stability Indicating Assay for Simultaneous Determination of Bupivacaine and Meloxicam in Bulk and Pharmaceutical Formulations by Using Rp-Hplc Method
    Seles, K. Stefi
    Padmavathi, Sakinala
    Rahaman, Shaik Abdul
    ShabanaAzmi
    ShinyGrace, D.
    AmreenSahana, Mohamad
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 (06): : 117 - 131
  • [46] Stability-Indicating Liquid Chromatographic Method for Determination of Saxagliptin and Structure Elucidation of the Major Degradation Products Using LC-MS
    Abdel-Ghany, Maha F.
    Abdel-Aziz, Omar
    Ayad, Miriam F.
    Tadros, Mariam M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (04) : 554 - 564
  • [47] Method development for the quantitative determination of captopril from Caco-2 cell monolayers by using LC-MS/MS
    Logoyda, Liliya
    Piponski, Marjan
    Kovalenko, Sergiy
    Dutchak, Olha
    Denefil, Olha
    Soroka, Yuriy
    Pidruchna, Svitlana
    Popovych, Dariya
    Susla, Oleksandr
    PHARMACIA, 2021, 68 (01) : 61 - 67
  • [48] Analytical quality by design approach to RP-HPLC method development and validation for simultaneous estimation of esomeprazole and naproxen in modified-release dosage form
    Khandokar Farjana Urmi
    Md. Saddam Nawaz
    S. M. Ashraful Islam
    Future Journal of Pharmaceutical Sciences, 8
  • [49] Development of an Analytical Method for Determination of Related Substances and Degradation Products of Cabotegravir Using Analytical Quality by Design Principles
    Kovac, Lidija
    Casar, Zdenko
    Lusin, Tina Trdan
    Roskar, Robert
    ACS OMEGA, 2022, 7 (10): : 8896 - 8905
  • [50] Analytical quality by design approach to RP-HPLC method development and validation for simultaneous estimation of esomeprazole and naproxen in modified-release dosage form
    Urmi, Khandokar Farjana
    Nawaz, Md. Saddam
    Islam, S. M. Ashraful
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 8 (01)