Development and validation of novel RP-HPLC method for midostaurin determination using analytical quality by design approach from regulatory perspective and determination of major degradation compounds of midostaurin using LC-MS

被引:17
|
作者
Saddala, Madhu Prakash Reddy [1 ]
Konduru, Naresh [2 ]
Gundla, Rambabu [1 ]
Kowtharapu, Leela Prasad [3 ]
机构
[1] GITAM Deemed Univ Hyderabad, Sch Sci, Dept Chem, Sangareddy 502329, India
[2] Zhuhai Resproly Pharmaceut Technol Co Ltd, Analyt Res & Dev, Zhuhai City, Peoples R China
[3] WUXI STA Wuxi App Tec Co Pharmaceut Co Ltd, Analyt Dev, Wuxi, Jiangsu, Peoples R China
关键词
analytical quality by design approach; degradation impurities; LC-MS technique; midostaurin; stability-indicating method; KINASE INHIBITOR;
D O I
10.1002/bmc.5486
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Midostaurin (MTN), designated as an orphan medicinal product, is emerging as an important drug for treating acute myeloid leukemia and advanced systematic mastocytosis. The proposed method was developed and validated to evaluate the related impurities of MTN. The impurities were separated using a YMC Trait C18 ExRS column (150 x 4.6 mm, 3 mu m). Mobile phase A consisted of a 10-mM concentration of phosphate buffer adjusted to pH 3.0 with diluted orthophosphoric acid, and mobile phase B consisted of 90% acetonitrile and 10% water. The optimized chromatographic conditions were as follows: flow rate, 0.5 mL min(-1); injection volume, 10 mu L; UV detection, 290 nm; and linear gradient program, up to 65 min. The method was developed using an analytical quality by design approach. A systematic flow chart shows the evaluation, control, and life cycle management method. As part of method evaluation, risk assessment was conducted. The method has been validated per current guidelines of the International Conference on Harmonization. The recovery study and linearity ranges were established from the limit of quantification to 150% optimal concentrations. The recovery was found to be between 95.5 and 102.5%, and linearity (r(2)) was 0.9998-0.9999 for all the identified impurities. The method precision results were achieved below 10% of relative standard deviation. Forced degradation studies were performed under chemical and physical stress conditions. The compound was sensitive to chemical stress conditions. During the study, the analyte degraded and was converted into the identified degradation impurities, and its molecular mass was found using the LC-MS technique.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR DETERMINATION OF LEVOFLOXACIN IN TABLET USING UV AND FLUORESCENCE DETECTORS SIMELTANIOUSLY
    Mando, H.
    Hasan, A.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2015, 6 (04): : 1401 - 1406
  • [22] An analytical "quality by design" approach in RP-HPLC method development and validation for reliable and rapid estimation of irinotecan in an injectable formulation
    Bhaskaran, Navya Ajitkumar
    Kumar, Lalit
    Reddy, M. Sreenivasa
    Pai, Girish K.
    ACTA PHARMACEUTICA, 2021, 71 (01) : 57 - 79
  • [23] Analytical Quality by Design Approach for Simultaneous Determination of Phytomarkers Orientin, Quercetin and Piperine in Nilaveembu Kudineer by RP-HPLC Method
    Sivagami, B.
    Sailaja, B.
    ORIENTAL JOURNAL OF CHEMISTRY, 2025, 41 (01) : 293 - 302
  • [24] Development and Validation of a Stability-indicating RP-HPLC Method Using Quality by Design for Estimating Captopril
    Veerubhotla, K.
    Walker, R. B.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 81 (01) : 45 - 56
  • [25] Development and validation of a method using supported liquid extraction for aldosterone determination in human plasma by LC-MS/MS
    Meunier, Cecile
    Blondelle, Dominique
    Faure, Patrice
    Baguet, Jean-Philippe
    Le Goff, Caroline
    Chabre, Olivier
    Ducros, Veronique
    CLINICA CHIMICA ACTA, 2015, 447 : 8 - 15
  • [26] Isolation and characterization of a degradation product of mexiletine hydrochloride using FT-IR, LC-MS and NMR: method development and validation of stability indicating RP-HPLC method for quantification of characterized impurity
    Muppavarapu, Venkatarao
    Challa, Gangu Naidu
    Gande, Mukteeshwar
    Billa, Praveen Reddy
    Beepala, Sateesh Kumar
    ANALYTICAL CHEMISTRY LETTERS, 2024, 14 (05) : 723 - 737
  • [27] Development and validation of RP-HPLC method for estimation of brexpiprazole in its bulk and tablet dosage form using Quality by Design approach
    Jagdale, Amol S.
    Pendbhaje, Nilesh S.
    Nirmal, Rupali V.
    Bachhav, Poonam M.
    Sumbre, Dayandeo B.
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 7 (01)
  • [28] Development and validation of RP-HPLC method for estimation of brexpiprazole in its bulk and tablet dosage form using Quality by Design approach
    Amol S. Jagdale
    Nilesh S. Pendbhaje
    Rupali V. Nirmal
    Poonam M. Bachhav
    Dayandeo B. Sumbre
    Future Journal of Pharmaceutical Sciences, 7
  • [29] LC-MS/MS Characterization of Forced Degradation Products of Repaglinide Quality by Design Approach for Stability-Indicating LC Method Development and Validation for Degradation Products
    Kancherla, Prasad
    Srinivas, Keesari
    Alegete, Pallavi
    Albaseer, Saeed. S.
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (06) : 740 - 757
  • [30] Quality by design approach for development and validation of a RP-HPLC method for simultaneous determination of co-administered levetiracetam and pyridoxine HCl in prepared tablets
    Hashem, Hisham
    El-Sayed, Heba M.
    MICROCHEMICAL JOURNAL, 2018, 143 : 55 - 63