Electrochemical Treatment of Contaminated Titanium Surfaces in Vitro: An Approach for Implant Surface Decontamination

被引:15
|
作者
Al-Hashedi, Ashwaq Ali [1 ,2 ]
Laurenti, Marco [3 ]
Abdallah, Mohamed-Nur [1 ]
Albuquerque, Rubens F., Jr. [4 ]
Tamimi, Faleh [1 ]
机构
[1] McGill Univ, Fac Dent, 3640 Univ St, Montreal, PQ H3A 0C7, Canada
[2] Sanaa Univ, Dept Prosthodont, Fac Dent, Wadi Dhaher Rd, Sanaa, Yemen
[3] Univ Complutense Madrid, Dept Phys Chem, Ave Seneca,2, E-28040 Madrid, Spain
[4] Univ Sao Paulo, Fac Dent Ribeirao Preto, 253 Ave Prof Dr Zeferino Vaz, Ribeirao Preto, SP, Brazil
来源
关键词
Ti implants; microbial biofilm; peri-implantitis; electrochemical treatment; decontamination; INDUCED PERI-IMPLANTITIS; STAPHYLOCOCCUS-EPIDERMIDIS BIOFILMS; CURRENT-INDUCED DETACHMENT; TOTAL HIP-ARTHROPLASTY; DENTAL IMPLANT; RE-OSSEOINTEGRATION; ELECTRIC-CURRENT; FOLLOW-UP; STAINLESS-STEEL; PURE TITANIUM;
D O I
10.1021/acsbiomaterials.6b00265
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Bacterial contamination on titanium implants can cause inflammation and eventually implant failure. Currently used methods for decontamination of implants have demonstrated limited success. Metal surfaces can be disinfected electrochemically. However, the effect of electrochemical treatments on biofilm-contaminated titanium is largely unknown. We hypothesized that electrochemical treatments are able to safely remove organic contamination and bacteria from titanium implants without altering their surfaces. This study was designed to assess the electrochemical properties of bacteria-contaminated surfaces in order to develop new treatments to clean titanium. Surface morphology, composition, bacterial load, and electrochemical properties of polished titanium discs were analyzed before and after biofilm contamination and subsequent decontamination with various electrochemical methods. The effect of the combination of the electrochemical with titanium brush cleaning was also evaluated. Results were then analyzed and compared to baseline readings (prior to contamination) using repeated measures ANOVA. Biofilm contamination increased the levels of carbon, nitrogen, and live bacteria on titanium surfaces while reducing their open circuit potential and corrosion resistance. Optimized electrochemical treatments with alternating current (-2.3 mA, + 22.5 mu A) and voltages (1.8 V), were bactericidal and able to completely decontaminate saliva-contaminated titanium surfaces within 5 min while preserving surface integrity and histological quality of mammalian tissues. Furthermore, with the aid of mechanical brushing, the optimized electrochemical treatment was able to achieve complete decontamination of biofilm-contaminated Ti surfaces. The electrochemical treatment seems to be promising and well worth investigating for the clinical management of peri-implant infections.
引用
下载
收藏
页码:1504 / 1518
页数:15
相关论文
共 50 条
  • [41] Electrochemical decontamination of titanium dental implants. An in vitro biofilm model study
    Virto, Leire
    Odeh, Veronica
    Garcia-Quismondo, Enrique
    Herrera, David
    Palma, Jesus
    Tamimi, Faleh
    Sanz, Mariano
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (05) : 486 - 497
  • [42] Biomimetic Calcium Phosphate Coatings for Bioactivation of Titanium Implant Surfaces: Methodological Approach and In Vitro Evaluation of Biocompatibility
    Kreller, Thomas
    Sahm, Franziska
    Bader, Rainer
    Boccaccini, Aldo R.
    Jonitz-Heincke, Anika
    Detsch, Rainer
    MATERIALS, 2021, 14 (13)
  • [43] Organic-inorganic surface modifications for titanium implant surfaces
    de Jonge, Lise T.
    Leeuwenburgh, Sander C. G.
    Wolke, Joop G. C.
    Jansen, John A.
    PHARMACEUTICAL RESEARCH, 2008, 25 (10) : 2357 - 2369
  • [44] Surface and corrosion electrochemical characterization of titanium foams for implant applications
    Menini, R
    Dion, MJ
    So, SKV
    Gauthier, M
    Lefebvre, LP
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (01) : B13 - B21
  • [45] In vivo and in vitro biofilm formation on two different titanium implant surfaces
    Buergers, Ralf
    Gerlach, Till
    Hahnel, Sebastian
    Schwarz, Frank
    Handel, Gerhard
    Gosau, Martin
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 156 - 164
  • [46] The role of bacterial corrosion on recolonization of titanium implant surfaces: An in vitro study
    Weller, Julia
    Vasudevan, Praveen
    Kreikemeyer, Bernd
    Ekat, Katharina
    Jackszis, Mario
    Springer, Armin
    Chatzivasileiou, Kyriaki
    Lang, Hermann
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2022, 24 (05) : 664 - 675
  • [47] In Vitro Evaluation of Implant Surface Decontamination Methods Based on Removal and Regrowth of Microorganisms
    Lee, Jung-Tae
    Jang, Il-Seok
    Moon, Jong-Hoon
    Yang, Seung-Min
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (06) : 1088 - 1094
  • [48] Preparation of superhydrophilic microrough titanium implant surfaces by alkali treatment
    Tugulu, Stefano
    Loewe, Konrad
    Scharnweber, Dieter
    Schlottig, Falko
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2010, 21 (10) : 2751 - 2763
  • [49] Preparation of superhydrophilic microrough titanium implant surfaces by alkali treatment
    Stefano Tugulu
    Konrad Löwe
    Dieter Scharnweber
    Falko Schlottig
    Journal of Materials Science: Materials in Medicine, 2010, 21 : 2751 - 2763
  • [50] An in vitro study of the treatment of implant surfaces with different instruments
    Mengel, R
    Buns, CE
    Mengel, C
    Flores-de-Jacoby, L
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (01) : 91 - 96