Isotretinoin Oxidation and Electroanalysis in a Pharmaceutical Drug Using a Boron-doped Diamond Electrode

被引:8
|
作者
Machini, W. B. S. [1 ]
Enache, T. A. [1 ]
Jorge, S. M. A. [1 ,2 ]
Oliveira-Brett, A. M. [1 ]
机构
[1] Univ Coimbra, Dept Chem, Fac Sci & Technol, P-3004535 Coimbra, Portugal
[2] Univ Estadual Paulista, Inst Biociencias, Dept Quim & Bioquim, BR-18618000 Botucatu, SP, Brazil
关键词
Isotretinoin; 13-cis-retinoic acid; Electrochemical oxidation; Boron-Doped Diamond; PERFORMANCE LIQUID-CHROMATOGRAPHY; 13-CIS RETINOIC ACID; ALL-TRANS; 13-CIS-RETINOIC ACID; 4-OXO METABOLITES; MASS-SPECTROMETRY; HUMAN SERUM; PLASMA; QUANTIFICATION; SEPARATION;
D O I
10.1002/elan.201600206
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotretinoin redox behaviour, by voltammetry, at the cathodic pre-treated boron doped diamond electrode by cyclic, differential pulse and square wave voltammetry, and by spectrophotometry in a wide pH range, was investigated. The isotretinoin oxidation was an irreversible, diffusion-controlled process, occurred in a three-step cascade mechanism, and the isotretinoin diffusion coefficient D13-cis-RA=7.35x10(-6)cm(2)s(-1), was calculated. The UV-Vis isotretinoin maximum absorption was pH-dependent. The detection limits LOD=0.53M, by differential pulse voltammetry, and LOD=0.38M, by UV-Vis spectroscopy, were obtained. The isotretinoin in the pharmaceutical drug Roacutan((R)), using differential pulse voltammetry, was determined.
引用
收藏
页码:2709 / 2715
页数:7
相关论文
共 50 条
  • [1] Electroanalysis of myoglobin and hemoglobin with a boron-doped diamond electrode
    Zhang, JD
    Oyama, M
    MICROCHEMICAL JOURNAL, 2004, 78 (02) : 217 - 222
  • [2] Electroanalysis of Benzalkonium Chloride in Ophthalmic Formulation by Boron-doped Diamond Electrode
    Alghamdi, Huda
    Alsaeedi, Majidah
    Buzid, Alyah
    Glennon, Jeremy D.
    Luong, John H. T.
    ELECTROANALYSIS, 2021, 33 (05) : 1137 - 1142
  • [3] Imipramine sensing in pharmaceutical formulations using boron-doped diamond electrode
    Oliveira, Sameque N.
    Ribeiro, Francisco W. P.
    Sousa, Camila P.
    Soares, Janete Eliza S.
    Suffredini, Hugo B.
    Becker, Helena
    de Lima-Neto, Pedro
    Correia, Adriana N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 118 - 124
  • [4] Electrochemical Oxidation of Organic Compounds Using Boron-Doped Diamond Electrode
    Chang, Ming
    Gao, Chengyao
    Jiang, Juyuan
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2009, 156 (02) : E50 - E54
  • [5] Electrochemical oxidation of phenol at boron-doped diamond electrode
    Iniesta, J
    Michaud, PA
    Panizza, M
    Cerisola, G
    Aldaz, A
    Comninellis, C
    ELECTROCHIMICA ACTA, 2001, 46 (23) : 3573 - 3578
  • [6] Electrochemical oxidation of phenol on boron-doped diamond electrode
    G. V. Kornienko
    N. V. Chaenko
    N. G. Maksimov
    V. L. Kornienko
    V. P. Varnin
    Russian Journal of Electrochemistry, 2011, 47
  • [7] Electrochemical oxidation of phenol on boron-doped diamond electrode
    Kornienko, G. V.
    Chaenko, N. V.
    Maksimov, N. G.
    Kornienko, V. L.
    Varnin, V. P.
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2011, 47 (02) : 225 - 229
  • [8] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Renáta Šelešovská
    Barbora Kränková
    Michaela Štěpánková
    Pavlína Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Tomáš Navrátil
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1701 - 1708
  • [9] Voltammetric assay of naproxen in pharmaceutical formulations using boron-doped diamond electrode
    Suryanarayan, V
    Zhang, Y
    Yoshihara, S
    Shirakashi, T
    ELECTROANALYSIS, 2005, 17 (11) : 925 - 932
  • [10] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Selesovska, Renata
    Krankova, Barbora
    Stepankova, Michaela
    Martinkova, Pavlina
    Janikova, Lenka
    Chylkova, Jaromira
    Navratil, Tomas
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1701 - 1708