Subtraction coronary CT angiography using second-generation 320-detector row CT

被引:32
|
作者
Yoshioka, Kunihiro [1 ]
Tanaka, Ryoichi [1 ]
Muranaka, Kenta [2 ]
Sasaki, Tadashi [2 ]
Ueda, Takanori [2 ]
Chiba, Takuya [2 ]
Takeda, Kouta [2 ]
Sugawara, Tsuyoshi [2 ]
机构
[1] Iwate Med Univ, Dept Radiol, Div Cardiovasc Radiol, Morioka, Iwate 0208505, Japan
[2] Iwate Med Univ Hosp, Ctr Radiol Sci, Morioka, Iwate 0208505, Japan
基金
日本学术振兴会;
关键词
Cardiac computed tomography; 320-Detector row CT; Angiography; Coronary artery calcification; Subtraction; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ARTERY-DISEASE;
D O I
10.1007/s10554-015-0630-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to explore the feasibility of subtraction coronary computed tomography angiography (CCTA) by second-generation 320-detector row CT in patients with severe coronary artery calcification using invasive coronary angiography (ICA) as the gold standard. This study was approved by the institutional board, and all subjects provided written consent. Twenty patients with calcium scores of > 400 underwent conventional CCTA and subtraction CCTA followed by ICA. A total of 82 segments were evaluated for image quality using a 4-point scale and the presence of significant (> 50 %) luminal stenosis by two independent readers. The average image quality was 2.3 +/- A 0.8 with conventional CCTA and 3.2 +/- A 0.6 with subtraction CCTA (P < 0.001). The percentage of segments with non-diagnostic image quality was 43.9 % on conventional CCTA versus 8.5 % on subtraction CCTA (P = 0.004). The segment-based diagnostic accuracy for detecting significant stenosis according to ICA revealed an area under the receiver operating characteristics curve of 0.824 (95 % confidence interval [CI], 0.750-0.899) for conventional CCTA and 0.936 (95 % CI 0.889-0.936) for subtraction CCTA (P = 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value for conventional CCTA were 88.2, 62.5, 62.5, and 88.2 %, respectively, and for subtraction CCTA they were 94.1, 85.4, 82.1, and 95.3 %, respectively. As compared to conventional, subtraction CCTA using a second-generation 320-detector row CT showed improvement in diagnostic accuracy at segment base analysis in patients with severe calcifications.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [41] Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results
    Xu, Lei
    Yang, Lin
    Fan, Zhanming
    Yu, Wei
    Lv, Biao
    Zhang, Zhaoqi
    EUROPEAN RADIOLOGY, 2011, 21 (05) : 936 - 943
  • [42] Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results
    Lei Xu
    Lin Yang
    Zhanming Fan
    Wei Yu
    Biao Lv
    Zhaoqi Zhang
    European Radiology, 2011, 21 : 936 - 943
  • [43] Transluminal attenuation gradient on 320-detector row CT (TAG320) adds incremental value to coronary angiography for detection of functionally significant stenosis
    Wong, D. T. L.
    Ko, B. S.
    Cameron, J. D.
    Nerlekar, N.
    Leung, M. C. H.
    Malaiapan, Y.
    Crossett, M.
    Leong, D. P.
    Meredith, I. T.
    Seneviratne, S. K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S2 - S2
  • [44] Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography
    Steigner, Michael L.
    Otero, Hansel J.
    Cai, Tianxi
    Mitsouras, Dimitrios
    Nallamshetty, Leelakrishna
    Whitmore, Amanda G.
    Ersoy, Hale
    Levit, Noah A.
    Di Carli, Marcelo F.
    Rybicki, Frank J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (01): : 85 - 90
  • [45] Narrowing the phase window width in prospectively ECG-gated single heart beat 320-detector row coronary CT angiography
    Michael L. Steigner
    Hansel J. Otero
    Tianxi Cai
    Dimitrios Mitsouras
    Leelakrishna Nallamshetty
    Amanda G. Whitmore
    Hale Ersoy
    Noah A. Levit
    Marcelo F. Di Carli
    Frank J. Rybicki
    The International Journal of Cardiovascular Imaging, 2009, 25 : 85 - 90
  • [46] The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT
    Takamura, Kazuhisa
    Fujimoto, Shinichiro
    Kawaguchi, Yuko
    Kato, Etsuro
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2019, 73 (1-2) : 58 - 64
  • [47] Comparison of Standard- and Low-Tube Voltage 320-Detector Row Volume CT Angiography in Detection of Intracranial Aneurysms with Digital Subtraction Angiography as Gold Standard
    Sun, Gang
    Ding, Juan
    Lu, Yang
    Li, Min
    Li, Li
    Li, Guo-ying
    Zhang, Xu-ping
    ACADEMIC RADIOLOGY, 2012, 19 (03) : 281 - 288
  • [48] Utility of 320-detector row CT for diagnosis and surgery for paraclinoid and intracavernous aneurysms
    Hosoda, K.
    Inoue, S.
    Fujita, A.
    Ohno, Y.
    Fujii, M.
    Sugimura, K.
    Kohmura, E. I. J. I.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 116 - 116
  • [49] Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results
    Gervaise, A.
    Louis, M.
    Batch, T.
    Loeuille, D.
    Noel, A.
    Guillemin, F.
    Blum, A.
    JOURNAL DE RADIOLOGIE, 2010, 91 (7-8): : 779 - 785
  • [50] Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population
    Gang, S.
    Min, L.
    Li, L.
    Guo-Ying, L.
    Lin, X.
    Qun, J.
    Hua, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 562 - 570