Subtraction coronary CT angiography using second-generation 320-detector row CT

被引:32
|
作者
Yoshioka, Kunihiro [1 ]
Tanaka, Ryoichi [1 ]
Muranaka, Kenta [2 ]
Sasaki, Tadashi [2 ]
Ueda, Takanori [2 ]
Chiba, Takuya [2 ]
Takeda, Kouta [2 ]
Sugawara, Tsuyoshi [2 ]
机构
[1] Iwate Med Univ, Dept Radiol, Div Cardiovasc Radiol, Morioka, Iwate 0208505, Japan
[2] Iwate Med Univ Hosp, Ctr Radiol Sci, Morioka, Iwate 0208505, Japan
基金
日本学术振兴会;
关键词
Cardiac computed tomography; 320-Detector row CT; Angiography; Coronary artery calcification; Subtraction; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ARTERY-DISEASE;
D O I
10.1007/s10554-015-0630-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to explore the feasibility of subtraction coronary computed tomography angiography (CCTA) by second-generation 320-detector row CT in patients with severe coronary artery calcification using invasive coronary angiography (ICA) as the gold standard. This study was approved by the institutional board, and all subjects provided written consent. Twenty patients with calcium scores of > 400 underwent conventional CCTA and subtraction CCTA followed by ICA. A total of 82 segments were evaluated for image quality using a 4-point scale and the presence of significant (> 50 %) luminal stenosis by two independent readers. The average image quality was 2.3 +/- A 0.8 with conventional CCTA and 3.2 +/- A 0.6 with subtraction CCTA (P < 0.001). The percentage of segments with non-diagnostic image quality was 43.9 % on conventional CCTA versus 8.5 % on subtraction CCTA (P = 0.004). The segment-based diagnostic accuracy for detecting significant stenosis according to ICA revealed an area under the receiver operating characteristics curve of 0.824 (95 % confidence interval [CI], 0.750-0.899) for conventional CCTA and 0.936 (95 % CI 0.889-0.936) for subtraction CCTA (P = 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value for conventional CCTA were 88.2, 62.5, 62.5, and 88.2 %, respectively, and for subtraction CCTA they were 94.1, 85.4, 82.1, and 95.3 %, respectively. As compared to conventional, subtraction CCTA using a second-generation 320-detector row CT showed improvement in diagnostic accuracy at segment base analysis in patients with severe calcifications.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [31] Body Size-Adapted Dose of Contrast Material and Scanning Protocol in 320-Detector Row CT Coronary Angiography
    Tatsugami, Fuminari
    Matsuki, Mitsuru
    Nakai, Go
    Inada, Yuki
    Kanazawa, Shuji
    Takeda, Yoshihiro
    Morita, Hideaki
    Takada, Haruhiko
    Yoshikawa, Shushi
    Fukumura, Katsunori
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) : 475 - 479
  • [32] Patient radiation dose in prospectively gated axial CT coronary angiography and retrospectively gated helical technique with a 320-detector row CT scanner
    Seguchi, Shigenobu
    Aoyama, Takahiko
    Koyama, Shuji
    Fujii, Keisuke
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (11) : 5579 - 5585
  • [33] Diagnostic value of four-dimensional CT angiography in arterial erectile dysfunction using 320-detector row dynamic volume CT
    Xu, Cheng-Cheng
    Ruan, Xin-Zhong
    Tang, Yi-Fan
    Pan, Jiao-Hai
    Wang, Guo-Yao
    Huang, Qiu-Li
    BIOSCIENCE REPORTS, 2017, 37
  • [34] Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320-Detector Row Coronary CT Angiography
    Ionita, C.
    Angel, E.
    Mitsouras, D.
    Rudin, S.
    Bednarek, D.
    Zaid, S.
    Wilson, M.
    Rybicki, F.
    MEDICAL PHYSICS, 2016, 43 (06) : 3781 - 3781
  • [35] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Qin, Jie
    Cai, Songwang
    Quan, Li
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C126 - C126
  • [36] Capability of abdominal 320-detector row CT for small vasculature assessment compared with that of 64-detector row CT
    Kitajima, Kazuhiro
    Maeda, Tetsuo
    Ohno, Yoshiharu
    Yoshikawa, Takeshi
    Konishi, Minoru
    Kanda, Tomonori
    Onishi, Yumiko
    Matsumoto, Keiko
    Koyama, Hisanobu
    Takenaka, Daisuke
    Sugimura, Kazuro
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 219 - 223
  • [37] Quantification of coronary flow using dynamic angiography with 320-detector row CT and motion coherence image processing: Detection of ischemia for intermediate coronary stenosis
    Nagao, Michinobu
    Yamasaki, Yuzo
    Kamitani, Takeshi
    Kawanami, Satoshi
    Sagiyama, Koji
    Yamanouchi, Torahiko
    Shimomiya, Yamato
    Matoba, Tetsuya
    Mukai, Yasushi
    Odashiro, Keita
    Baba, Shingo
    Maruoka, Yasuhiro
    Kitamura, Yoshiyuki
    Nishie, Akihiro
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 996 - 1003
  • [38] Clinical indications and utilization of 320-detector row CT in 2500 outpatients
    Tabibian, Benjamin
    Roach, Cayce J.
    Hanson, Eric H.
    Wynn, Brad L.
    Orrison, William W., Jr.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2011, 35 (04) : 266 - 274
  • [39] Accuracy of 320-detector row nonsubtracted and subtracted volume CT angiography in evaluating small cerebral aneurysms
    Chen, Wenhua
    Xing, Wei
    He, Zhongming
    Peng, Ya
    Wang, Caoye
    Wang, Qi
    JOURNAL OF NEUROSURGERY, 2017, 127 (04) : 725 - 731
  • [40] Diagnostic Accuracy of Noninvasive Coronary Angiography With 320-Detector Row Computed Tomography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Lehman, Sam J.
    Hope, Sarah A.
    Crossett, Marcus P.
    Troupis, John M.
    Meredith, Ian T.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (10): : 1429 - 1435