Infrared detectors characterization for CO2 DIAL measurement

被引:7
|
作者
Refaat, TF [1 ]
Abedin, MN [1 ]
Koch, GJ [1 ]
Ismail, S [1 ]
Singh, UN [1 ]
机构
[1] Sci & Technol Corp, Hampton, VA 23666 USA
关键词
atmospheric CO2; DIAL measurements; IR detectors; detector characterization;
D O I
10.1117/12.504893
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Knowledge of the spatial and temporal distribution of atmospheric carbon dioxide (CO2) is important for understanding the carbon natural cycle, predicting its future levels and its impact on global warming and climate changes. Laser technology has advanced considerably during the past few years in the 2-micron region where strong optimum lines are available for measuring CO2 Using the Differential Absorption Lidar (DIAL) technique. Although several types of detectors might be suitable for this particular wavelength, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the signal-to-noise ratio and minimizes the background signal, thereby increasing the instrument sensitivity and dynamic range. In this paper the detector requirements for a long range CO2 DIAL measurement will be presented. The requirements were compared to commercially available and newly developed infrared (IR) detectors. The IR detectors considered for this study consist of the well developed InGaAs and HgCdTe p-n junction photodiodes, beside the newly developed and proposed InGaAsSb and InGaSb detectors. All of the detectors were characterized and their performances were compared with the CO2 DIAL detector requirements. The characterization experiments included spectral response, dark current and noise measurements. CO2 DIAL, measurements using InGaAs detectors were attempted and indicated the need for better detector performance. While InGaAs detectors showed the closest performance to the instrument requirements, InGaSb detectors indicated a promising solution.
引用
下载
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [41] INFRARED STUDIES OF CO AND CO2 ADSORPTION ON PT/CEO2 - THE CHARACTERIZATION OF ACTIVE-SITES
    DANIEL, DW
    JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (13): : 3891 - 3899
  • [42] A NUMERICAL APPROACH TO MEASUREMENT OF CO2 EXCHANGE TRANSIENTS BY INFRARED GAS-ANALYSIS
    PETERSON, RB
    FERRANDINO, FJ
    PLANT PHYSIOLOGY, 1984, 76 (04) : 976 - 978
  • [43] SIMPLE INFRARED SPECTROSCOPIC METHOD FOR THE MEASUREMENT OF EXPIRED (CO2)-C-13
    HIRANO, S
    KANAMATSU, T
    TAKAGI, Y
    ABEI, T
    ANALYTICAL BIOCHEMISTRY, 1979, 96 (01) : 64 - 69
  • [44] Fourier Transfer Infrared Measurement of CO2 Photogeneration from Polyethylene, Polypropylene, and Polyesters
    Christensen, Paul A.
    Egerton, Terry A.
    Fernando, Sudesh S.
    White, Jim R.
    POLYMER DEGRADATION AND PERFORMANCE, 2009, 1004 : 147 - 158
  • [46] Infrared evanescent-field microscope using CO2 laser for reflectance measurement
    Nakano, T.
    Kawata, S.
    Optik (Jena), 1993, 94 (04): : 159 - 162
  • [47] A quantitative evaluation of spurious results in the infrared spectroscopic measurement of CO2 isotope ratios
    Mansfield, CD
    Rutt, HN
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (04): : 689 - 696
  • [48] BANDWIDTH MEASUREMENT OF WIDEBAND INFRARED DETECTORS
    CORCORAN, VJ
    SMITH, WT
    APPLIED OPTICS, 1972, 11 (04) : 881 - +
  • [49] Co2 laser based mobile dial system for atmospheric pollutants monitoring
    Bellecci, C
    Martellucci, S
    Aversa, P
    Gaudio, P
    Richetta, M
    Zoccali, R
    ENVIRONMENTAL ENGINEERING & RENEWABLE ENERGY, 1998, : 173 - 178
  • [50] MEASURING CO2 LASERS WITH PYROELECTRIC DETECTORS.
    Dooley, Don
    1600, (06):