Infrared detectors characterization for CO2 DIAL measurement

被引:7
|
作者
Refaat, TF [1 ]
Abedin, MN [1 ]
Koch, GJ [1 ]
Ismail, S [1 ]
Singh, UN [1 ]
机构
[1] Sci & Technol Corp, Hampton, VA 23666 USA
关键词
atmospheric CO2; DIAL measurements; IR detectors; detector characterization;
D O I
10.1117/12.504893
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Knowledge of the spatial and temporal distribution of atmospheric carbon dioxide (CO2) is important for understanding the carbon natural cycle, predicting its future levels and its impact on global warming and climate changes. Laser technology has advanced considerably during the past few years in the 2-micron region where strong optimum lines are available for measuring CO2 Using the Differential Absorption Lidar (DIAL) technique. Although several types of detectors might be suitable for this particular wavelength, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the signal-to-noise ratio and minimizes the background signal, thereby increasing the instrument sensitivity and dynamic range. In this paper the detector requirements for a long range CO2 DIAL measurement will be presented. The requirements were compared to commercially available and newly developed infrared (IR) detectors. The IR detectors considered for this study consist of the well developed InGaAs and HgCdTe p-n junction photodiodes, beside the newly developed and proposed InGaAsSb and InGaSb detectors. All of the detectors were characterized and their performances were compared with the CO2 DIAL detector requirements. The characterization experiments included spectral response, dark current and noise measurements. CO2 DIAL, measurements using InGaAs detectors were attempted and indicated the need for better detector performance. While InGaAs detectors showed the closest performance to the instrument requirements, InGaSb detectors indicated a promising solution.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [21] CO2 DIAL system:: Construction, measurements and future development
    Viceník, J
    11TH SLOVAK-CZECH-POLISH OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 1999, 3820 : 314 - 321
  • [22] REMOTE PROBING OF THE ATMOSPHERE USING A CO2 DIAL SYSTEM
    KILLINGER, DK
    MENYUK, N
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1981, 17 (09) : 1917 - 1929
  • [23] Silicon bolometer and micro variable infrared filter for CO2 measurement
    Hara, H
    Kishi, N
    Iwaoka, H
    2000 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS, 2000, : 139 - 140
  • [24] Development of DIAL for CO2 and CH4 in the atmosphere
    Uchiumi, M
    Vasa, NJ
    Fujiwara, M
    Yokoyama, S
    Maeda, M
    Uchino, O
    LIDAR REMOTE SENSING FOR INDUSTRY AND ENVIRONMENT MONITORING III, 2003, 4893 : 141 - 149
  • [25] Improvement of Calabria university CO2 laser dial system
    Aversa, P
    Bellecci, C
    Michelangeli, GB
    Caputi, G
    DeDonato, F
    Gaudio, P
    Valentini, M
    Zoccali, R
    LIDAR ATMOSPHERIC MONITORING, 1997, 3104 : 154 - 157
  • [26] Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2
    Francesco Trepiccione
    Francesco Maria Iena
    Laura Catalini
    Francesco Martino Carpi
    Mogens Koed
    Sebastian Frische
    Pflügers Archiv - European Journal of Physiology, 2017, 469 : 1267 - 1275
  • [27] Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2
    Trepiccione, Francesco
    Iena, Francesco Maria
    Catalini, Laura
    Carpi, Francesco Martino
    Koed, Mogens
    Frische, Sebastian
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2017, 469 (10): : 1267 - 1275
  • [28] NEW INFRARED SYSTEM FOR MEASUREMENT OF CO2, CO, H2O FROM AIRCRAFT
    SCHMITT, R
    ATMOSPHERIC ENVIRONMENT, 1975, 9 (09) : 865 - 866
  • [29] ABSOLUTE INTENSITY MEASUREMENT OF CO2 OVERTONE TRANSITIONS IN THE NEAR-INFRARED
    CAMPARGUE, A
    CHARVAT, A
    PERMOGOROV, D
    CHEMICAL PHYSICS LETTERS, 1994, 223 (5-6) : 567 - 572
  • [30] Development of an infrared diagnostic instrument for the measurement of CO2 isotope ratios in breath
    Mansfield, CD
    Rutt, HN
    SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY II, PROCEEDINGS OF, 1999, 3603 : 36 - 48