The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study

被引:2
|
作者
Lin, Chih-Jen [1 ,2 ]
Tsai, Ming-Hsu [3 ]
Wu, Yu-Ling [1 ,2 ]
Lung, Hsuan [1 ,2 ]
Chen, Hung-Shyong [3 ,4 ]
Wu, Aaron Yu-Jen [1 ,2 ]
机构
[1] Kaohsiung Chang Gung Mem Hosp, Dept Dent, Kaohsiung 833, Taiwan
[2] Chang Gung Univ, Coll Med, Kaohsiung 833, Taiwan
[3] Cheng Shiu Univ, Dept Mech Engn, Kaohsiung 833, Taiwan
[4] Cheng Shiu Univ, Ctr Environm Toxin & Emerging Contaminant Res, Kaohsiung 833, Taiwan
关键词
Er; Cr: YSGG Laser; implantitis; implantoplasty; TiUnite surface; FRACTURE-RESISTANCE; CONSENSUS REPORT; DENTAL IMPLANTS; YAG LASER; IRRADIATION; THERAPY; DIAMETER; WORKSHOP; DISEASES; ERBIUM;
D O I
10.3390/jfb13030133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although laser irradiation and implantoplasty (IP) are both treatment options for periimplantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface implants were treated with an Er, Cr: YSGG laser at 0.5 to 2 W on the panel energy setting and 20 Hz under water irrigation. In experiment 2, all implant surfaces were treated with the IP procedure first, then irradiated with the Er, Cr: YSGG laser. All samples were analyzed by stereomicroscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and surface topography. Stereomicroscopy and SEM revealed no obvious surface change at any energy setting once the surface was polished with the IP procedure, whereas damage was caused to the TiUnite original implant surface when the Er, Cr: YSGG laser panel energy was set at 1 W or higher. EDS showed no significant difference in element composition once the surface was polished with the IP procedure, while a compositional change was detected when the Er, Cr: YSGG laser panel energy was set to 0.5 W or higher to irradiate the original TiUnite surface. Surface roughness may be related to laser irradiation energy, but no significant changes occurred following IP. These results indicated that the Er, Cr: YSGG laser may have little effect on the post-IP surface compared with the virgin TiUnite surface.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Morphological changes of bovine mandibular bone irradiated by Er,Cr:YSGG laser:: An in vitro study
    Wang, XG
    Ishizaki, NT
    Suzuki, N
    Kimura, Y
    Matsumoto, K
    JOURNAL OF CLINICAL LASER MEDICINE & SURGERY, 2002, 20 (05): : 245 - 250
  • [42] In Vitro Study of Er,Cr:YSGG Laser Effects When Used for the Prevention of Dentin Demineralization
    Ferreira, Elizabete dos Santos
    Kato Prates, Ilka Tiemy
    Machado dos Santos, Sergio Luiz, Jr.
    Del Valle, Matheus
    Zezell, Denise M.
    Ana, Patricia A.
    XXVI BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2018, VOL. 2, 2019, 70 (02): : 825 - 829
  • [43] Debonding of LDSVs utilising Er,Cr:YSGG laser irradiation with fractional technique: an in vitro study
    Al-Karadaghi, S. S.
    Jawad, Hussein A.
    AUSTRALIAN DENTAL JOURNAL, 2023, 68 (02) : 125 - 134
  • [44] Evaluation of the Effect of NovaMin and Er,Cr:YSGG Laser on Remineralization of Erosive Lesions of Primary Enamel Teeth: An In Vitro Study
    Sadabadi, Yoones
    Mehran, Majid
    Rezvani, Mohammad Bagher
    Asnaashari, Mohammad
    Haghgoo, Roza
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2023, 14
  • [45] THE EFFECT OF ER,CR:YSGG LASER CONDITIONING ON DENTIN BOND STRENGTH AND NANOLEAKAGE OF UNIVERSAL ADHESIVE SYSTEMS: AN IN VITRO STUDY
    Karatas, Ozcan
    Sagsoz, Omer
    Kapti, Zeynep Sumeyye
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 : S156 - S167
  • [46] Effect of surface treatment with sandblasting and Er,Cr:YSGG laser on bonding of stainless steel orthodontic brackets to silver amalgam
    Oskoee, Parnian-Alizadeh
    Kachoei, Mojgan
    Rikhtegaran, Sahand
    Fathalizadeh, Farzaneh
    Navimipour, Elmira-Jafari
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (02): : E292 - E296
  • [47] In vitro study: conventional vs. laser (Er,Cr:YSGG) subgingival scaling and root planing; morphologic analysis and efficiency of calculus removal using macroscopic, SEM and laser scanning
    Ezzat A.
    Maden I.
    Hilgers R.-D.
    Gutknecht N.
    Lasers in Dental Science, 2018, 2 (2) : 81 - 87
  • [48] Antibacterial effect of Er,Cr:YSGG laser and chlorhexidine 2% against Entrococcus faecalis in dentin tubules (in vitro study)
    Kangarloo, Ali
    Salar, Omid
    Zerafatjou, Golaleh
    Kalhori, Katayoun A. M.
    Sohrabi, Mona
    Fekrazad, Reza
    LASER PHYSICS, 2021, 31 (08)
  • [49] Influence of Different Proportions of External Irrigation During the Er,Cr:YSGG Laser Irradiation on Wear and Roughness of Root Surface
    Pimentel Lopes de Oliveira, Guilherme Jose
    Pinotti, Felipe Eduardo
    Carvalho, Heglecia da Luz
    Scardueli, Cassio Rocha
    Chierici Marcantonio, Rosemary Adriana
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2016, 7 (01) : 51 - 55
  • [50] Factors Affecting Implant Surface Roughness and Platform Alterations After Implantoplasty: An In Vitro Study Simulating Different Clinical Scenarios
    Burgueno-Barris, Genis
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (04) : 739 - 746