The Effect of an Er, Cr: YSGG Laser Combined with Implantoplasty Treatment on Implant Surface Roughness and Morphologic Analysis: A Pilot In Vitro Study

被引:2
|
作者
Lin, Chih-Jen [1 ,2 ]
Tsai, Ming-Hsu [3 ]
Wu, Yu-Ling [1 ,2 ]
Lung, Hsuan [1 ,2 ]
Chen, Hung-Shyong [3 ,4 ]
Wu, Aaron Yu-Jen [1 ,2 ]
机构
[1] Kaohsiung Chang Gung Mem Hosp, Dept Dent, Kaohsiung 833, Taiwan
[2] Chang Gung Univ, Coll Med, Kaohsiung 833, Taiwan
[3] Cheng Shiu Univ, Dept Mech Engn, Kaohsiung 833, Taiwan
[4] Cheng Shiu Univ, Ctr Environm Toxin & Emerging Contaminant Res, Kaohsiung 833, Taiwan
关键词
Er; Cr: YSGG Laser; implantitis; implantoplasty; TiUnite surface; FRACTURE-RESISTANCE; CONSENSUS REPORT; DENTAL IMPLANTS; YAG LASER; IRRADIATION; THERAPY; DIAMETER; WORKSHOP; DISEASES; ERBIUM;
D O I
10.3390/jfb13030133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although laser irradiation and implantoplasty (IP) are both treatment options for periimplantitis, no studies have yet combined these two treatment solutions. The aim of this study was to identify the effect of an Er, Cr: YSGG laser on the IP surface. In experiment 1, TiUnite anodized surface implants were treated with an Er, Cr: YSGG laser at 0.5 to 2 W on the panel energy setting and 20 Hz under water irrigation. In experiment 2, all implant surfaces were treated with the IP procedure first, then irradiated with the Er, Cr: YSGG laser. All samples were analyzed by stereomicroscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and surface topography. Stereomicroscopy and SEM revealed no obvious surface change at any energy setting once the surface was polished with the IP procedure, whereas damage was caused to the TiUnite original implant surface when the Er, Cr: YSGG laser panel energy was set at 1 W or higher. EDS showed no significant difference in element composition once the surface was polished with the IP procedure, while a compositional change was detected when the Er, Cr: YSGG laser panel energy was set to 0.5 W or higher to irradiate the original TiUnite surface. Surface roughness may be related to laser irradiation energy, but no significant changes occurred following IP. These results indicated that the Er, Cr: YSGG laser may have little effect on the post-IP surface compared with the virgin TiUnite surface.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Evaluation of Er,Cr:YSGG laser for hard tissue ablation: An in vitro study
    Zhang X.
    Xie S.
    Zhan Z.
    Zhao H.
    Guo J.
    Ye Q.
    Frontiers of Optoelectronics in China, 2010, 3 (2): : 163 - 168
  • [22] Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study
    Kottmann, Lucia
    Franzen, Rene
    Conrads, Georg
    Wolfart, Stefan
    Marotti, Juliana
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [23] The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
    Tawse-Smith, Andrew
    Kota, Akash
    Jayaweera, Yathen
    van Vuuren, Wendy Jansen
    Ma, Sunyoung
    BRAZILIAN ORAL RESEARCH, 2016, 30
  • [24] Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study
    Lucia Kottmann
    Rene Franzen
    Georg Conrads
    Stefan Wolfart
    Juliana Marotti
    International Journal of Implant Dentistry, 9
  • [25] The effect of using Er,Cr:YSGG laser in debonding stainless steel orthodontic brackets: an in vitro study
    Sedky Y.
    Gutknecht N.
    Lasers in Dental Science, 2018, 2 (1) : 13 - 18
  • [26] Combined effect of Er,Cr:YSGG laser and casein phosphopeptide amorphous calcium phosphate on the prevention of enamel demineralization: An in-vitro study
    Adel, Samar M.
    Marzouk, Eiman S.
    El-Harouni, Nadia
    ANGLE ORTHODONTIST, 2020, 90 (03) : 369 - 375
  • [27] Using an Er,Cr:YSGG laser to remove lithium disilicate restorations: A pilot study
    Gurney, Michael L.
    Sharpies, Stanley D.
    Phillips, Wesley B.
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (01): : 90 - 94
  • [28] Influence of the Angle of Irradiation of the Er,Cr:YSGG Laser on the Morphology, Attachment of Blood Components, Roughness, and Root Wear: In Vitro Study
    Pimentel Lopes de Oliveira, Guilherme Jose
    Pavone, Chaine
    Cezar Sampaio, Jose Eduardo
    Chierici Marcantonio, Rosemary Adriana
    LASERS IN SURGERY AND MEDICINE, 2010, 42 (09) : 683 - 691
  • [29] Surface conditioning of artificial caries lesions with Er, Cr:YSGG laser before resin infiltration: an in vitro study
    Kalender B.
    Lausch J.
    Gutknecht N.
    Gorucu J.
    Lasers in Dental Science, 8 (1)
  • [30] The Impact of Combined Application of Cilantro White Varnish and ER,CR:YSGG Laser on Enamel Resistance to Caries: An In Vitro Study
    Abdullah, Hussein Sami
    Qasim, Aisha Aram
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (12): : 534 - 544