Modelling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods

被引:31
|
作者
Waide, V
Cristofolini, L
Stolk, J
Verdonschot, N
Boogaard, GJ
Toni, A
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Bologna, DIEM, I-40136 Bologna, Italy
[3] Univ Nijmegen, Orthopaed Res Lab, Nijmegen, Netherlands
关键词
fibrous tissue layer; composite femurs; cemented implants; finite element analysis; experimental simulations; silicone elastomer;
D O I
10.1016/S0021-9290(03)00258-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The long-term fixation of cemented femoral components may be jeopardised by the presence of a fibrous tissue layer at the bone-cement interface. This study used both experimental and finite element (FE) methods to investigate the load transfer characteristics of two types of cemented hip replacements (Lubinus SPII and Muller-Curved) with a fibrous tissue layer. The experimental part investigated six stems of each type, where these were implanted in composite femurs with a specially selected silicone elastomer modelling the soft interfacial layer. Two fibrous tissue conditions were examined: a layer covering the full cement mantle, representing a revision condition; and a layer covering the proximal portion of the cement mantle, representing a non-revised implant with partial debonding and fibrous tissue formation. The FE method was used to model the full fibrous tissue layer condition, for both implants. The layer was modelled as a homogeneous, linearly isotropic material. A cross-comparison was performed of the experimental and FE findings. Agreement between experimental and FE models was verified to be within 15%. Varying the stiffness parameter of the FE soft tissue layer had little influence on the cortical bone strains, though had considerable effect on the cement strains. Stress shielding occurred for both stems under both fibrous tissue conditions, with the greatest reduction around the calcar. However, the cortical bone strains were generally larger than those for the equivalent well-fixed stems. The fibrous tissue layer was not found to increase the general strain pattern of the cement mantle, though localised regions of high stress were detected. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:13 / 26
页数:14
相关论文
共 50 条
  • [21] Finite element analysis of interfacial crack behaviour in cemented total hip arthroplasty
    Achour, T.
    Tabeti, M. S. H.
    Bouziane, M. M.
    Benbarek, S.
    Bouiadjra, B. Bachir
    Mankour, A.
    COMPUTATIONAL MATERIALS SCIENCE, 2010, 47 (03) : 672 - 677
  • [22] Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements
    Bah, Mamadou T.
    Nair, Prasanth B.
    Browne, Martin
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (10) : 1235 - 1243
  • [23] Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements
    School of Engineering Sciences, University of Southampton, Southampton, SO17 1BJ, United Kingdom
    Med. Eng. Phys., 1600, 10 (1235-1243):
  • [24] Finite element modelling of magnetic constrained layer damping
    Ruzzene, M
    Oh, J
    Baz, A
    JOURNAL OF SOUND AND VIBRATION, 2000, 236 (04) : 657 - 682
  • [25] Arbitrary active constrained layer damping treatments on beams: Finite element modelling and experimental validation
    Vasques, C. M. A.
    Mace, B. R.
    Gardonio, P.
    Rodrigues, J. Dias
    COMPUTERS & STRUCTURES, 2006, 84 (22-23) : 1384 - 1401
  • [26] Comparative Finite Element Analysis of the Debonding Process in Different Concepts of Cemented Hip Implants
    Perez, M. A.
    Palacios, J.
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (06) : 2093 - 2106
  • [27] Advances in the finite element modelling of soft tissue deformation
    Clift, SE
    MEDICAL ENGINEERING & PHYSICS, 2005, 27 (10) : 809 - 809
  • [28] Finite Element Analysis of Stress Distribution of Cemented Stem After Total Hip Replacement
    Zheng, Xiao-Wen
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2765 - 2768
  • [29] Probabilistic design of a newly designed cemented hip prosthesis using finite element method
    Kayabasi, Oguz
    Ekici, Bulent
    MATERIALS & DESIGN, 2008, 29 (05) : 963 - 971
  • [30] Comparative Finite Element Analysis of the Debonding Process in Different Concepts of Cemented Hip Implants
    M. A. Pérez
    J. Palacios
    Annals of Biomedical Engineering, 2010, 38 : 2093 - 2106