Fully automatic reconstruction of personalized 3D volumes of the proximal femur from 2D X-ray images

被引:20
|
作者
Yu, Weimin [1 ]
Chu, Chengwen [1 ]
Tannast, Moritz [2 ]
Zheng, Guoyan [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, Stauffacherstr 78, CH-3014 Bern, Switzerland
[2] Univ Bern, Dept Orthopaed Surg, Inselspital, Bern, Switzerland
关键词
Segmentation; Deformable registration; Reconstruction; 2D-3D; Random forest regression; B-spline; REGISTRATION; PELVIS; CT;
D O I
10.1007/s11548-016-1400-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate preoperative planning is crucial for the outcome of total hip arthroplasty. Recently, 2D pelvic X-ray radiographs have been replaced by 3D CT. However, CT suffers from relatively high radiation dosage and cost. An alternative is to reconstruct a 3D patient-specific volume data from 2D X-ray images. In this paper, based on a fully automatic image segmentation algorithm, we propose a new control point-based 2D-3D registration approach for a deformable registration of a 3D volumetric template to a limited number of 2D calibrated X-ray images and show its application to personalized reconstruction of 3D volumes of the proximal femur. The 2D-3D registration is done with a hierarchical two-stage strategy: the scaled-rigid 2D-3D registration stage followed by a regularized deformable B-spline 2D-3D registration stage. In both stages, a set of control points with uniform spacing are placed over the domain of the 3D volumetric template first. The registration is then driven by computing updated positions of these control points with intensity-based 2D-2D image registrations of the input X-ray images with the associated digitally reconstructed radiographs, which allows computing the associated registration transformation at each stage. Evaluated on datasets of 44 patients, our method achieved an overall surface reconstruction accuracy of and an average Dice coefficient of . We further investigated the cortical bone region reconstruction accuracy, which is important for planning cementless total hip arthroplasty. An average cortical bone region Dice coefficient of and an inner cortical bone surface reconstruction accuracy of were found. In summary, we developed a new approach for reconstruction of 3D personalized volumes of the proximal femur from 2D X-ray images. Comprehensive experiments demonstrated the efficacy of the present approach.
引用
下载
收藏
页码:1673 / 1685
页数:13
相关论文
共 50 条
  • [31] 3D shape reconstruction of the femur from planar X-ray images using statistical shape and appearance models
    Daniel Nolte
    Shuqiao Xie
    Anthony M. J. Bull
    BioMedical Engineering OnLine, 22
  • [32] DENSE FEMUR RECONSTRUCTION FROM TWO X-RAY IMAGES USING GENERIC 3D MODEL WITH TWIST CORRECTION
    Kim, Ki-jung
    Lee, Seungkyu
    Kim, Yoon Hyuk
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 3645 - 3649
  • [33] Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction
    Desbat, L
    Mennessier, C
    Champleboux, G
    COMPTES RENDUS BIOLOGIES, 2002, 325 (04) : 431 - 438
  • [34] Gradient-based registration of 3D MR and 2D x-ray images
    Tomazevic, D
    Likar, B
    Pernus, F
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 327 - 332
  • [35] Iterative approach for 3D reconstruction of the femur from un-calibrated 2D radiographic images
    Youn, Kibeom
    Park, Moon Seok
    Lee, Jehee
    MEDICAL ENGINEERING & PHYSICS, 2017, 50 : 89 - 95
  • [36] 2D–3D reconstruction of distal forearm bone from actual X-ray images of the wrist using convolutional neural networks
    Ryoya Shiode
    Mototaka Kabashima
    Yuta Hiasa
    Kunihiro Oka
    Tsuyoshi Murase
    Yoshinobu Sato
    Yoshito Otake
    Scientific Reports, 11
  • [37] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [38] A survey of 3D reconstruction algorithms from 2D images
    Hajjdiab, Hassan
    IMECS 2006: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, 2006, : 562 - 567
  • [39] A 3D Magnetospheric CT Reconstruction Method Based on 3D GAN and Supplementary Limited-Angle 2D Soft X-Ray Images
    Wang, R. C.
    Li, Dalin
    Sun, Tianran
    Peng, Xiaodong
    Yang, Zhen
    Wang, J. Q.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2023, 128 (01)
  • [40] Revisiting Contour-Driven and Knowledge-Based Deformable Models: Application to 2D-3D Proximal Femur Reconstruction from X-ray Images
    Chenes, Christophe
    Schmid, Jerome
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VI, 2021, 12906 : 451 - 460