Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction

被引:2
|
作者
Desbat, L [1 ]
Mennessier, C [1 ]
Champleboux, G [1 ]
机构
[1] Univ Grenoble 1, Fac Med, CNRS, UMR 5525,IAB,TIMC,IMAG, F-38706 La Tronche, France
关键词
interventional imaging; X-ray; image intensifier calibration; calibration grid without information lost; efficient sampling of the X-ray transform; fast and efficient Fourier interpolation;
D O I
10.1016/S1631-0691(02)01445-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Image intensifiers suffer from distortions due to magnetic fields. In order to use this X-ray projections images for computer-assisted medical interventions, image intensifiers need to be calibrated. Opaque markers are often used for the correction of the image distortion and the estimation of the acquisition geometry parameters. Information under the markers is then lost. In this work, we consider the calibration of image intensifiers in the framework of 3D reconstruction from several 2D X-ray projections. In this context, new schemes of marker distributions are proposed for 2D X-ray sensor calibration. They are based on efficient sampling conditions of the parallel-beam X-ray transform when the detector and source trajectory is restricted to a circle around the measured object. Efficient sampling are essentially subset of standard sampling in this situation. The idea is simply to exploit the data redundancy of standard sampling and to replace some holes of efficient schemes by markers. Optimal location of markers in the sparse efficient sampling geometry can thus be found. In this case, the markers can stay on the sensor during the measurement with - theoretically - no loss of information (when the signal-to-noise ratio is large). Even if the theory is based on the parallel-beam X-ray transform, numerical experiments on both simulated and real data are shown in the case of weakly divergent beam geometry. We show that the 3D reconstruction from simulated data with interlaced markers is essentially the same as those obtained from data with no marker. We show that efficient Fourier interpolation formulas based on optimal sparse sampling schemes can be used to recover the information hidden by the markers. (C) 2002 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
引用
下载
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [1] Calibration of X-ray projections in 3D reconstruction
    Wang, P
    Mou, XQ
    Qin, ZY
    Cai, YL
    VISUALIZATION AND OPTIMIZATION TECHNIQUES, 2001, 4553 : 44 - 49
  • [2] Calibration of X-ray Radiographs and its Feasible Application for 2D/3D Reconstruction of the Proximal Femur
    Schumann, Steffen
    Zheng, Guoyan
    Nolte, Lutz-Peter
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 470 - 473
  • [3] Optimal 3D surface reconstruction from a small number of conventional 2D X-ray images
    Prakoonwit, Simant
    Benjamin, Ralph
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (04) : 197 - 222
  • [4] Reconstruction of 3D catheter paths from 2D X-ray projections
    Bender, HJ
    Männer, R
    Poliwoda, C
    Roth, S
    Walz, M
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 981 - 989
  • [5] 3D localization from 2D X-ray projection
    Dagmar Bertsche
    Volker Rasche
    Wolfgang Rottbauer
    Ina Vernikouskaya
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1553 - 1558
  • [6] 3D localization from 2D X-ray projection
    Bertsche, Dagmar
    Rasche, Volker
    Rottbauer, Wolfgang
    Vernikouskaya, Ina
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (09) : 1553 - 1558
  • [7] 3D interventional imaging with 2D x-ray detectors
    Desbat, L
    Champleboux, G
    Fleute, M
    Komarek, P
    Mennessier, C
    Monteil, B
    Rodet, T
    Bessou, P
    Coulomb, M
    Ferretti, G
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 973 - 980
  • [8] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [9] 3D Reconstruction of a Femur Shaft using a Model and Two 2D X-ray Images
    Wei Wei
    Wang Guorong
    Chen Hua
    ICCSSE 2009: PROCEEDINGS OF 2009 4TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION, 2009, : 720 - +
  • [10] New Approach for 3D Reconstruction of Femur using 2D Conventional X-Ray Images
    Jamshidi, E.
    Nackenhorst, U.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S479 - S480