Optimal calibration marker mesh for 2D X-ray sensors in 3D reconstruction

被引:2
|
作者
Desbat, L [1 ]
Mennessier, C [1 ]
Champleboux, G [1 ]
机构
[1] Univ Grenoble 1, Fac Med, CNRS, UMR 5525,IAB,TIMC,IMAG, F-38706 La Tronche, France
关键词
interventional imaging; X-ray; image intensifier calibration; calibration grid without information lost; efficient sampling of the X-ray transform; fast and efficient Fourier interpolation;
D O I
10.1016/S1631-0691(02)01445-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Image intensifiers suffer from distortions due to magnetic fields. In order to use this X-ray projections images for computer-assisted medical interventions, image intensifiers need to be calibrated. Opaque markers are often used for the correction of the image distortion and the estimation of the acquisition geometry parameters. Information under the markers is then lost. In this work, we consider the calibration of image intensifiers in the framework of 3D reconstruction from several 2D X-ray projections. In this context, new schemes of marker distributions are proposed for 2D X-ray sensor calibration. They are based on efficient sampling conditions of the parallel-beam X-ray transform when the detector and source trajectory is restricted to a circle around the measured object. Efficient sampling are essentially subset of standard sampling in this situation. The idea is simply to exploit the data redundancy of standard sampling and to replace some holes of efficient schemes by markers. Optimal location of markers in the sparse efficient sampling geometry can thus be found. In this case, the markers can stay on the sensor during the measurement with - theoretically - no loss of information (when the signal-to-noise ratio is large). Even if the theory is based on the parallel-beam X-ray transform, numerical experiments on both simulated and real data are shown in the case of weakly divergent beam geometry. We show that the 3D reconstruction from simulated data with interlaced markers is essentially the same as those obtained from data with no marker. We show that efficient Fourier interpolation formulas based on optimal sparse sampling schemes can be used to recover the information hidden by the markers. (C) 2002 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
引用
下载
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [21] 3D reconstruction and visualization from 2D X-ray CT images in the study of ceramic membrane microstructure
    Thomasova, Barbora
    Thomas, Jan
    Soucek, Kamil
    Michalek, Ondrej
    Gembalova, Lucie
    JOURNAL OF CERAMIC PROCESSING RESEARCH, 2020, 21 (06): : 712 - 724
  • [22] 3D/2D image registration: The impact of X-ray views and their number
    Tomazevic, Dejan
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 450 - +
  • [23] 3D fault surface reconstruction based on 2D mesh triangulation
    Weng, Wen-Yong
    Lin, Sun
    Dai, Xiao-Xia
    Tang, Pei-Pei
    Xiao, An-Cheng
    Energy Education Science and Technology Part A: Energy Science and Research, 2014, 32 (06): : 4983 - 4992
  • [24] Fully automatic reconstruction of personalized 3D volumes of the proximal femur from 2D X-ray images
    Weimin Yu
    Chengwen Chu
    Moritz Tannast
    Guoyan Zheng
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 1673 - 1685
  • [25] 2D or 3D? Benefits of combining both in a single X-ray system
    Frank, UE
    IEEE/CPMT/SEMI(R) 28TH INTERNATIONAL ELECTRONICS MANUFACTURING TECHNOLOGY SYMPOSIUM, 2003, : 389 - 393
  • [26] X-CTRSNet: 3D cervical vertebra CT reconstruction and segmentation directly from 2D X-ray images
    Ge, Rongjun
    He, Yuting
    Xia, Cong
    Xu, Chenchu
    Sun, Weiya
    Yang, Guanyu
    Li, Junru
    Wang, Zhihua
    Yu, Hailing
    Zhang, Daoqiang
    Chen, Yang
    Luo, Limin
    Li, Shuo
    Zhu, Yinsu
    KNOWLEDGE-BASED SYSTEMS, 2022, 236
  • [27] 3D reconstruction of archaeological artefacts from 2-D X-ray images
    Angheluta, L. M.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2018, 12 (11-12): : 705 - 712
  • [28] A 3D Magnetospheric CT Reconstruction Method Based on 3D GAN and Supplementary Limited-Angle 2D Soft X-Ray Images
    Wang, R. C.
    Li, Dalin
    Sun, Tianran
    Peng, Xiaodong
    Yang, Zhen
    Wang, J. Q.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2023, 128 (01)
  • [29] A Combined Calibration of 2D and 3D Sensors A Novel Calibration for Laser Triangulation Sensors based on Point Correspondences
    Walch, Alexander
    Eitzinger, Christian
    PROCEEDINGS OF THE 2014 9TH INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS (VISAPP), VOL 1, 2014, : 89 - 95
  • [30] 2D-to-3D: A Review for Computational 3D Image Reconstruction from X-ray Images
    Maken, Payal
    Gupta, Abhishek
    ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2023, 30 (01) : 85 - 114