Influence of arterial input function (AIF) on quantitative prostate dynamic contrast-enhanced (DCE) MRI and zonal prostate anatomy

被引:12
|
作者
Ziayee, F. [1 ]
Mueller-Lutz, A. [1 ]
Gross, J. [1 ]
Quentin, M. [1 ]
Ullrich, T. [1 ]
Heusch, P. [1 ]
Arsov, C. [2 ]
Rabenalt, R. [2 ]
Albers, P. [2 ]
Antoch, G. [1 ]
Wittsack, H. J. [1 ]
Schimmoeller, L. [1 ]
机构
[1] Univ Dusseldorf, Med Fac, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
[2] Univ Dusseldorf, Med Fac, Dept Urol, D-40225 Dusseldorf, Germany
关键词
Arterial input function; Quantitative perfusion parameters; Tofts model; Dynamic contrast enhanced imaging; Prostate MRI; PHARMACOKINETIC PARAMETERS; CANCER-DETECTION; PI-RADS; LOCALIZATION; PERFORMANCE; VALIDATION; SEQUENCES; SYSTEM;
D O I
10.1016/j.mri.2018.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Reproducibility of quantitative perfusion analysis of DCE requires a standardized AIF acquisition. However, there are many different approaches for AIF assessment so that the absolute values of perfusion parameters may vary depending on the used method. This study analyzes the influence of the method of AIF determination on quantitative DCE-MRI. Methods: In this retrospective, single-center, cohort study three different methods of AIF determination in 50 consecutive patients with multiparametric MRI of the prostate were conducted. As a reference, AIF was selected manually by defining a region of interest in an artery manually (AIF(m)). The second method (AIF(a)), based on an automated algorithm and the third, population-derived AlFp where then compared. Primary endpoint were differences in the performance of the perfusion parameters K-trans, ve and k(ep) regarding the AIF acquisition methods, secondary endpoints consisted of the evaluation of differences in the peripheral and transition zone of the prostate (PZ, TZ). Results: In all three methods, K-trans, ve, and k(ep) were significantly higher in PZ than in TZ with K-trans showing least overlapping. There were no significant differences for K-trans determined with AIF(m), and AIF(a) (0.3 +/- 0.2 min(-1) for PZ for both and 0.5 +/- 0.3 min(-1) for TZ in AIF(m) and 0.4 +/- 0.3 min(-1) in AIF(a)), while there were great differences between AIF(a) and AIF(p) and AIF(m) and AIF(p) (0.1 +/- 0.03 min(-1) for TZ and PZ in AIF(p)). Spearman test demonstrated good correlation of values for K-trans and K-ep in all 3 methods (p >= 0.76). AIF(a) showed a success rate of 98% in finding the artery. Conclusion: AIF(a) is a recommendable user-independent automatical method to determine quantitative perfusion parameters allowing an objective measurement and saving interactive time for the radiologist. AIF(p) may be applied as second alternative method.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 50 条
  • [1] Arterial input function for quantitative dynamic contrast-enhanced MRI to diagnose prostate cancer
    Ziayee, Farid
    Mueller-Lutz, Anja
    Gross, Janina
    Ullrich, Tim
    Quentin, Michael
    Arsov, Christian
    Antoch, Gerald
    Wittsack, Hans-Joerg
    Schimmoeller, Lars
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2022, 28 (02) : 108 - 114
  • [2] Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI
    Peled, Sharon
    Vangel, Mark
    Kikinis, Ron
    Tempany, Clare M.
    Fennessy, Fiona M.
    Fedorov, Andrey
    ACADEMIC RADIOLOGY, 2019, 26 (09) : E241 - E251
  • [3] Impact of Arterial Input Function Selection on the Accuracy of Dynamic Contrast-Enhanced MRI Quantitative Analysis for the Diagnosis of Clinically Significant Prostate Cancer
    Azahaf, Mustapha
    Haberley, Marc
    Betrouni, Nacim
    Ernst, Olivier
    Behal, Helene
    Duhamel, Alain
    Ouzzane, Adil
    Puech, Philippe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (03) : 737 - 749
  • [4] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Kleppesto, Magne
    Bjornerud, Atle
    Groote, Inge Rasmus
    Kim, Minjae
    Vardal, Jonas
    Larsson, Christopher
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (01) : 105 - 112
  • [5] Correction of arterial input function in dynamic contrast-enhanced MRI of the liver
    Wang, Hesheng
    Cao, Yue
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (02) : 411 - 421
  • [6] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Magne Kleppestø
    Atle Bjørnerud
    Inge Rasmus Groote
    Minjae Kim
    Jonas Vardal
    Christopher Larsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 105 - 112
  • [7] Benefit of dynamic contrast-enhanced (DCE) imaging for prostate cancer detection depending on readers experience in prostate MRI
    Ziayee, F.
    Schimmoeuroller, L.
    Boschheidgen, M.
    Kasprowski, L.
    Al-Monajjed, R.
    Quentin, M.
    Radtke, J. P.
    Albers, P.
    Antoch, G.
    Ullrich, T.
    CLINICAL RADIOLOGY, 2024, 79 (03) : e468 - e474
  • [8] Dynamic Contrast-Enhanced (DCE) MRI
    Li, Xin
    Huang, Wei
    Holmes, James H.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2024, 32 (01) : 47 - 61
  • [9] Quantitative dynamic contrast-enhanced MRI for mouse models using automatic detection of the arterial input function
    Kim, Jae-Hun
    Im, Geun Ho
    Yang, Jehoon
    Choi, Dongil
    Lee, Won Jae
    Lee, Jung Hee
    NMR IN BIOMEDICINE, 2012, 25 (04) : 674 - 684
  • [10] Automated Determination of Arterial Input Function for DCE-MRI of the Prostate
    Zhu, Yingxuan
    Chang, Ming-Ching
    Gupta, Sandeep N.
    MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963