Anthropomorphic liver phantom with flow for multimodal image-guided liver therapy research and training

被引:20
|
作者
Rethy, Anna [1 ,2 ]
Saeternes, Jorn Ove [3 ]
Halgunset, Jostein [3 ]
Marvik, Ronald [2 ,4 ]
Hofstad, Erlend F. [2 ,5 ]
Sanchez-Margallo, Juan A. [5 ,6 ]
Lango, Thomas [2 ,5 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Canc Res & Mol Med, Trondheim, Norway
[2] Trondheim Reg & Univ Hosp, St Olavs Hosp, Norwegian Natl Advisory Unit Ultrasound & Image G, Trondheim, Norway
[3] NTNU, Dept Lab Med Childrens & Womens Hlth, Trondheim, Norway
[4] St Olavs Hosp, Dept Gastrointestinal Surg, Trondheim, Norway
[5] SINTEF, Dept Med Technol, N-7465 Trondheim, Norway
[6] Univ Extremadura, Dept Comp Syst & Telemat Engn, Badajoz, Spain
关键词
Liver phantom; Blood flow; Laparoscopic liver surgery; Ultrasound; Navigation; ULTRASOUND; CT; SCATTERING; CRYOGEL; MDCT;
D O I
10.1007/s11548-017-1669-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The objective of this study was to develop a multimodal, permanent liver phantom displaying functional vasculature and common pathologies, for teaching, training and equipment development in laparoscopic ultrasound and navigation. Methods Molten wax was injected simultaneously into the portal and hepatic veins of a human liver. Upon solidification of the wax, the surrounding liver tissue was dissolved, leaving a cast of the vessels. A connection was established between the two vascular trees by manually manipulating the wax. The cast was placed, along with different multimodal tumor models, in a liver shaped mold, which was subsequently filled with a polymer. After curing, the wax was melted and flushed out of the model, thereby establishing a system of interconnected channels, replicating the major vasculature of the original liver. Thus, a liquid can be circulated through the model in a way that closely mimics the natural blood flow. Results Both the tumor models, i.e., the metastatic tumors, hepatocellular carcinoma and benign cyst, and the vessels inside the liver model, were clearly visualized by all the three imaging modalities: CT, MR and ultrasound. Doppler ultrasound images of the vessels proved the blood flow functionality of the phantom. Conclusion By a two-step casting procedure, we produced a multimodal liver phantom, with open vascular channels, and tumor models, that is the next best thing to practicing imaging and guidance procedures in animals or humans. The technique is in principle applicable to any organ of the body.
引用
收藏
页码:61 / 72
页数:12
相关论文
共 50 条
  • [21] A computer-controlled pump and realistic, anthropomorphic respiratory phantom for validating image-guided systems
    Lin, Ralph
    Wilson, Emmanuel
    Tang, Jonathan
    Stoianovici, Dan
    Cleary, Kevin
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [22] Adapting population liver motion models for individualized online image-guided therapy
    Nguyen, Thao-Nguyen
    Moseley, Joanne L.
    Dawson, Laura A.
    Jaffray, David A.
    Brock, Kristy K.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3945 - +
  • [23] IMAGE-GUIDED ROBOTIC STEREOTACTIC BODY RADIATION THERAPY FOR 62 LIVER METASTASES
    Vautravers, C.
    Dewas, S.
    Boncceau, F.
    Adenis, A.
    Lacornerie, T.
    Lartigau, E.
    Mirabel, X.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S115 - S115
  • [24] Development of Laparoscopic and Open Models for Training and Assessing Image-guided Liver Tumor Ablation
    Diab, K.
    Olino, K.
    Agle, S.
    Kochat, S.
    Kahrig, K.
    Delao, S.
    Tyler, D.
    Brown, K.
    ANNALS OF SURGICAL ONCOLOGY, 2016, 23 : S103 - S104
  • [25] Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework
    Collins, Jarrod A.
    Weis, Jared A.
    Heiselman, Jon S.
    Clements, Logan W.
    Simpson, Amber L.
    Jarnagin, William R.
    Miga, Michael I.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (07) : 1502 - 1510
  • [26] Emulation of the laparoscopic environment for image-guided liver surgery via an abdominal phantom system with anatomical ligamenture
    Heiselman, Jon S.
    Collins, Jarrod A.
    Clements, Logan W.
    Weis, Jared A.
    Simpson, Amber L.
    Geevarghese, Sunil K.
    Jarnagin, William R.
    Miga, Michael I.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [27] A Pulsatile flow phantom for image-guided HIFU hemostasis of blood vessels
    Greaby, R
    Vaezy, S
    4th International Symposium on Therapeutic Ultrasound, 2005, 754 : 68 - 70
  • [28] Image-guided acoustic hemostasis for hemorrhage in the posterior liver
    Burgess, Sean
    Zderic, Vesna
    Vaezy, Shahram
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (01): : 113 - 119
  • [29] Percutaneous image-guided radiofrequency ablation of liver tumors
    Lencioni, Riccardo
    Crocetti, Laura
    Della Pina, Maria Clotilde
    Cioni, Dania
    ABDOMINAL IMAGING, 2009, 34 (05): : 547 - 556
  • [30] PATIENT STABILITY DURING IMAGE-GUIDED LIVER SBRT
    Seppenwoolde, Y.
    Romer, A. Mendez
    Wunderink, W.
    Wentzler, D.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S20 - S20