Development of the HiLight™ scintillator for computed tomography medical imaging

被引:78
|
作者
Duclos, SJ
Greskovich, CD
Lyons, RJ
Vartuli, JS [1 ]
Hoffman, DM
Riedner, RJ
Lynch, MJ
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
[2] GE Global Res, Schenectady, NY USA
关键词
scintillator; computed tomography; ceramic;
D O I
10.1016/S0168-9002(03)01022-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The image quality of computed tomography (CT) medical scanners is extremely sensitive to afterglow, radiation damage and optical non-uniformities of scintillators used in X-ray detectors. This represents a tough challenge in the design of scintillator materials with optimum properties. Discussion will center on the development and properties of the first commercialized transparent ceramic scintillator, the (Y,Gd)(2)O-3:Eu-based HiLight(TM) scintillator used in GE Medical System's CT products. The flexibility of the ceramic scintillator platform has enabled it to be engineered to satisfy the changing needs of CT imaging, which is demonstrated by its successful incorporation into over 8000 CT systems worldwide since 1988. The ceramic process makes possible uniform co-doping at ppm levels to control electronic defects responsible for afterglow, reducing it to levels below detectibility in CT images. Annealing of the material in controlled oxygen atmospheres, combined with rapid oxygen diffusion along grain boundaries in the ceramic, reduces radiation damage to negligible values. Transient thermoluminescence of these materials will be discussed as a diagnostic of electronic trap levels,responsible for both afterglow and radiation damage. Finally, with the increased scan speed requirements of modern CT systems, energy transfer between the Eu activator and other rare-earth ions can be used to speed the radiative decay of the scintillator, ensuring the material's continued viability in future CT systems. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 71
页数:4
相关论文
共 50 条
  • [31] Computed Tomography Imaging in Oncology
    Forrest, Lisa J.
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2016, 46 (03) : 499 - +
  • [32] Functional Computed Tomography Imaging
    Fink, Christian
    Brix, Gunnar
    Halliburton, Sandra Simon
    Schindera, Sebastian
    Goh, Vicky
    INVESTIGATIVE RADIOLOGY, 2012, 47 (01) : 1 - 1
  • [33] Imaging of the heart with computed tomography
    Thomas G. Flohr
    Bernd M. Ohnesorge
    Basic Research in Cardiology, 2008, 103 : 161 - 173
  • [34] Molecular imaging with computed tomography
    Lanza, Gregory M.
    Pan, Dipanjan
    CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (01) : 1 - 2
  • [35] Imaging of the heart with computed tomography
    Flohr, Thomas G.
    Ohnesorge, Bernd M.
    BASIC RESEARCH IN CARDIOLOGY, 2008, 103 (02) : 161 - 173
  • [36] X-ray computed tomography: from medical imaging to dimensional metrology
    Villarraga-Gomez, Herminso
    Herazo, Ericka L.
    Smith, Stuart T.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2019, 60 : 544 - 569
  • [37] Feasibility study of x-ray diffraction computed tomography for medical imaging
    Kleuker, U
    Suortti, P
    Weyrich, W
    Spanne, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2911 - 2923
  • [38] The computed tomography imaging spectrometer
    Descour, MR
    Tkaczyk, TS
    Ford, BK
    Lynch, RM
    Locke, A
    Dereniak, E
    2003 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2003, : 460 - 461
  • [39] Computed Tomography for Imaging the Breast
    John M. Boone
    Alex L. C. Kwan
    Kai Yang
    George W. Burkett
    Karen K. Lindfors
    Thomas R. Nelson
    Journal of Mammary Gland Biology and Neoplasia, 2006, 11 : 103 - 111
  • [40] Imaging the lungs with Computed tomography
    Hansell, DM
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2000, 19 (05): : 71 - 79