Development of the HiLight™ scintillator for computed tomography medical imaging

被引:78
|
作者
Duclos, SJ
Greskovich, CD
Lyons, RJ
Vartuli, JS [1 ]
Hoffman, DM
Riedner, RJ
Lynch, MJ
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
[2] GE Global Res, Schenectady, NY USA
关键词
scintillator; computed tomography; ceramic;
D O I
10.1016/S0168-9002(03)01022-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The image quality of computed tomography (CT) medical scanners is extremely sensitive to afterglow, radiation damage and optical non-uniformities of scintillators used in X-ray detectors. This represents a tough challenge in the design of scintillator materials with optimum properties. Discussion will center on the development and properties of the first commercialized transparent ceramic scintillator, the (Y,Gd)(2)O-3:Eu-based HiLight(TM) scintillator used in GE Medical System's CT products. The flexibility of the ceramic scintillator platform has enabled it to be engineered to satisfy the changing needs of CT imaging, which is demonstrated by its successful incorporation into over 8000 CT systems worldwide since 1988. The ceramic process makes possible uniform co-doping at ppm levels to control electronic defects responsible for afterglow, reducing it to levels below detectibility in CT images. Annealing of the material in controlled oxygen atmospheres, combined with rapid oxygen diffusion along grain boundaries in the ceramic, reduces radiation damage to negligible values. Transient thermoluminescence of these materials will be discussed as a diagnostic of electronic trap levels,responsible for both afterglow and radiation damage. Finally, with the increased scan speed requirements of modern CT systems, energy transfer between the Eu activator and other rare-earth ions can be used to speed the radiative decay of the scintillator, ensuring the material's continued viability in future CT systems. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 71
页数:4
相关论文
共 50 条
  • [21] Development of maxillary sinuses in relation to the development of cranium in children on computed tomography imaging
    Kicinski, Przemyslaw
    Podgorski, Michal
    Malachowska, Beata
    Grzelak, Piotr
    Polguj, Michal
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] COMPUTED MEDICAL IMAGING
    HOUNSFIELD, GN
    JOURNAL DE RADIOLOGIE, 1980, 61 (6-7): : 459 - 468
  • [23] COMPUTED MEDICAL IMAGING
    HOUNSFIELD, GN
    SCIENCE, 1980, 210 (4465) : 22 - 28
  • [24] COMPUTED MEDICAL IMAGING
    HOUNSFIELD, GN
    MEDICAL PHYSICS, 1980, 7 (04) : 283 - 290
  • [25] Investigation of scintillator coated CCDs for medical imaging
    Lees, JE
    Bassford, D
    Fraser, GW
    Monk, D
    Early, M
    Ott, RJ
    Moody, I
    Blackshaw, E
    Perkins, AC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 9 - 13
  • [26] Scintillator Detectors with Integrated Nanophotonics for Medical Imaging
    Yi, Ya Sha
    Liu, Bo
    PHOTONICS SPECTRA, 2015, 49 (04) : 58 - 62
  • [27] Investigation of scintillator coated CCDs for medical imaging
    Lees, JE
    Bassford, D
    Fraser, GW
    Monk, D
    Early, M
    Ott, RJ
    Moody, I
    Blackshaw, E
    Perkins, AC
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3565 - 3568
  • [28] X-ray computed tomography - a truly remarkable medical development
    Husband, J
    Dombrowe, G
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926): : 97 - 98
  • [29] Digital imaging and computed tomography
    Kapur, Vivesh V.
    CURRENT SCIENCE, 2017, 112 (07): : 1317 - 1317
  • [30] Computed tomography for imaging the breast
    Boone, John M.
    Kwan, Alex L. C.
    Yang, Kai
    Burkett, George W.
    Lindfors, Karen K.
    Nelson, Thomas R.
    JOURNAL OF MAMMARY GLAND BIOLOGY AND NEOPLASIA, 2006, 11 (02) : 103 - 111