Development of the HiLight™ scintillator for computed tomography medical imaging

被引:78
|
作者
Duclos, SJ
Greskovich, CD
Lyons, RJ
Vartuli, JS [1 ]
Hoffman, DM
Riedner, RJ
Lynch, MJ
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
[2] GE Global Res, Schenectady, NY USA
关键词
scintillator; computed tomography; ceramic;
D O I
10.1016/S0168-9002(03)01022-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The image quality of computed tomography (CT) medical scanners is extremely sensitive to afterglow, radiation damage and optical non-uniformities of scintillators used in X-ray detectors. This represents a tough challenge in the design of scintillator materials with optimum properties. Discussion will center on the development and properties of the first commercialized transparent ceramic scintillator, the (Y,Gd)(2)O-3:Eu-based HiLight(TM) scintillator used in GE Medical System's CT products. The flexibility of the ceramic scintillator platform has enabled it to be engineered to satisfy the changing needs of CT imaging, which is demonstrated by its successful incorporation into over 8000 CT systems worldwide since 1988. The ceramic process makes possible uniform co-doping at ppm levels to control electronic defects responsible for afterglow, reducing it to levels below detectibility in CT images. Annealing of the material in controlled oxygen atmospheres, combined with rapid oxygen diffusion along grain boundaries in the ceramic, reduces radiation damage to negligible values. Transient thermoluminescence of these materials will be discussed as a diagnostic of electronic trap levels,responsible for both afterglow and radiation damage. Finally, with the increased scan speed requirements of modern CT systems, energy transfer between the Eu activator and other rare-earth ions can be used to speed the radiative decay of the scintillator, ensuring the material's continued viability in future CT systems. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:68 / 71
页数:4
相关论文
共 50 条
  • [1] A proton Computed Tomography based medical imaging system
    Scaringella, M.
    Bruzzi, M.
    Bucciolini, M.
    Carpinelli, M.
    Cirrone, G. A. P.
    Civinini, C.
    Cuttone, G.
    Lo Presti, D.
    Pallotta, S.
    Pugliatti, C.
    Randazzo, N.
    Romano, F.
    Sipala, V.
    Stancampiano, C.
    Talamonti, C.
    Vanzi, E.
    Zani, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [2] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [3] Development of medical scintillator
    LIU Bo & SHI ChaoshuNational Synchrotron Radiation Laboratory. University of Science and Technology of China
    Chinese Science Bulletin, 2002, (13) : 1057 - 1063
  • [4] Development of medical scintillator
    Liu, B
    Shi, CS
    CHINESE SCIENCE BULLETIN, 2002, 47 (13): : 1057 - 1063
  • [5] Scintillator phosphors for medical imaging
    General Electric Corporate Research, and Development Cent, Schenectady, United States
    Electrochem Soc Interface, 2 (34-38):
  • [6] Entities and relations in medical imaging: An analysis of computed tomography reporting
    Marwede, Dirk
    Fielding, James Matthew
    APPLIED ONTOLOGY, 2007, 2 (01) : 67 - 79
  • [7] Coherent scatter computed tomography - A novel medical imaging technique
    Schlomka, JP
    Harding, A
    van Stevendaal, U
    Grass, M
    Harding, G
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 256 - 265
  • [8] Anti-Scattering Perovskite Scintillator Arrays for High-Resolution Computed Tomography Imaging
    Song, Jinmei
    He, Yuhong
    Hu, Haijing
    Li, Mingbian
    Li, Chenglong
    Yang, Bai
    Wei, Haotong
    ADVANCED MATERIALS, 2025, 37 (09)
  • [9] New development of imaging theory and algorithms in computed tomography
    Pan, X
    MEDICAL PHYSICS, 2005, 32 (06) : 2081 - 2082
  • [10] Scintillator performance considerations for dedicated breast computed tomography
    Vedantham, Srinivasan
    Shi, Linxi
    Karellas, Andrew
    RADIATION DETECTORS IN MEDICINE, INDUSTRY, AND NATIONAL SECURITY XVIII, 2017, 10393