摘要
Objectives - To assess the accuracy and reproducibility of a new magnetic resonance cholangiopancreatography sequence (MRCP), using long echo time and "single shot" acquisition (providing high-contrast chick slices: 20 mm or more) in the morphological analysis of the biliary free and pancreatic ducts. Methods - Fifty four patients with biliary and/or pancreatic disease were investigated with MRCP "single shot" chick slices. Biliary ducts were explored with MRCP "single shot", coronal and oblique coronal 20 mm thick slices on a 256 x 256 matrix. Natives pictures were reviewed by three independent radiologists, from three different institutions. MRCP results were compared with reference examinations in 54 cases (direct biligraphy methods: 54, CT scan: 11, endoscopic ultrasonography: 6, surgery: 6). Results - For defection of bile duct dilatation, the agreement of MRCP "single shot" chick slices was more than 96% (Kappa > 0.92) and the inter-observer agreement was excellent (Kappa = 0.92). For detection of biliary tree and/or pancreatic duct obstruction, MRCP "single shot" chick slice sensitivity was above 89% and specificity was 75%. The malignant nature of the lesions was determined with a sensitivity of 100% and a specificity of 92%. MRCP "single shot" thick slices could not differentiate pancreatic carcinomas from distal main bile duct cholangiocarcinomas. MRCP single shot" thick slices did not defect small stones (less than or equal to 3 mm) of the the common bile duct. Conclusion - The excellent sensitivity specificity and infer-observer agreement of MRCP "single shot" thick slices can be used to limit invasive imaging methods in the diagnosis of extrahepatic cholestasis.
引用
下载
收藏
页码:888 / 895
页数:8
相关论文
共 50 条
  • [41] MR cholangiopancreatography in single shot fast spin echo sequence
    Lefevre, F
    Crouzet, P
    Gaucher, H
    Chapuis, F
    Beot, S
    Boccaccini, H
    Bazin, C
    Regent, D
    JOURNAL DE RADIOLOGIE, 1998, 79 (05): : 415 - 425
  • [42] Magnetic resonance cholangio-pancreatography (MRCP) versus endoscopic retrograde cholangiopancreatography (ERCP): Significance in patients with pancreatico-biliary disease and interventional ERCP
    Klockmann, K
    Knuth, P
    Stobbe, G
    Stoeckmann, F
    GASTROENTEROLOGY, 1999, 116 (04) : A1138 - A1138
  • [43] Magnetic resonance imaging (MRI) of pulmonary lesions with single shot fast and ultra-fast gradient echo imaging
    Bischoff, HG
    Knopp, MV
    Geissler, C
    Schirren, J
    Manegold, C
    Drings, P
    vanKaick, G
    EUROPEAN JOURNAL OF CANCER, 1997, 33 : 1035 - 1035
  • [44] Lumbar magnetic resonance myelography using a three-dimensional half-Fourier single-shot fast spin echo sequence
    Tsuchiya, K
    Mizutani, Y
    Hanaoka, H
    Inaoka, S
    Hachiya, J
    Kassai, Y
    Suzuki, H
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (02): : 136 - 139
  • [45] Magnetic resonance cholangio pancreatography evaluation of intrahepatic bile duct variations with updated classification
    Nayman, Alaaddin
    Ozbek, Orhan
    Erol, Seyit
    Karakus, Hayrettin
    Kaya, Hasan Emin
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2016, 22 (06) : 489 - 494
  • [46] Liver-Specific Contrast-Enhanced Magnetic Resonance Cholangio-Pancreatography (Ce-MRCP) in Non-Invasive Diagnosis of Iatrogenic Biliary Leakage
    Argiro, Renato
    Sensi, Bruno
    Siragusa, Leandro
    Bellini, Luigi
    Conte, Luigi Edoardo
    Riccetti, Camilla
    Blanco, Giovanna Del Vecchio
    Troncone, Edoardo
    Floris, Roberto
    Salavracos, Mike
    Tisone, Giuseppe
    Anselmo, Alessandro
    DIAGNOSTICS, 2023, 13 (10)
  • [47] Use of fast spin echo for phase shift magnetic resonance thermometry
    Vogel, MW
    Pattynama, PMT
    Lethimonnier, FL
    Le Roux, P
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (04) : 507 - 512
  • [48] Fast spin-echo for multiple mouse magnetic resonance phenotyping
    Nieman, BJ
    Bock, NA
    Bishop, J
    Sled, JG
    Chen, XJ
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 532 - 537
  • [49] Magnetic resonance cholangiopancreatography: Comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences
    Papanikolaou, N
    Karantanas, AH
    Heracleous, E
    Costa, JC
    Gourtsoyiannis, N
    MAGNETIC RESONANCE IMAGING, 1999, 17 (09) : 1255 - 1260
  • [50] Comparison of conventional spin-echo and fast spin-echo magnetic resonance imaging in the canine brain
    Sage, JE
    Samii, VF
    Abramson, CJ
    Green, EM
    Smith, M
    Dingus, C
    VETERINARY RADIOLOGY & ULTRASOUND, 2006, 47 (03) : 249 - 253