Single shot fast spin echo long TE magnetic resonance cholangio-pancreatography

被引:0
|
作者
Mougenel, JL
Hudziak, H
Ernst, O
Dupas, B
Lefevre, F
Barraud, H
Watelet, J
Cezard, O
Regent, D
Bigard, MA
机构
[1] CHU Nancy, Serv Hepatogastroenterol, Nancy, France
[2] CHRU Lille, Serv Radiol Est, Lille, France
[3] CHU Hotel Dieu, Serv Radiol, Nantes, France
[4] CHU, Serv Radiol, Nancy, France
[5] CHU, Serv Med B, Nancy, France
来源
关键词
magnetic resonance; pancreas; biliary duct; cholangiography;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objectives - To assess the accuracy and reproducibility of a new magnetic resonance cholangiopancreatography sequence (MRCP), using long echo time and "single shot" acquisition (providing high-contrast chick slices: 20 mm or more) in the morphological analysis of the biliary free and pancreatic ducts. Methods - Fifty four patients with biliary and/or pancreatic disease were investigated with MRCP "single shot" chick slices. Biliary ducts were explored with MRCP "single shot", coronal and oblique coronal 20 mm thick slices on a 256 x 256 matrix. Natives pictures were reviewed by three independent radiologists, from three different institutions. MRCP results were compared with reference examinations in 54 cases (direct biligraphy methods: 54, CT scan: 11, endoscopic ultrasonography: 6, surgery: 6). Results - For defection of bile duct dilatation, the agreement of MRCP "single shot" chick slices was more than 96% (Kappa > 0.92) and the inter-observer agreement was excellent (Kappa = 0.92). For detection of biliary tree and/or pancreatic duct obstruction, MRCP "single shot" chick slice sensitivity was above 89% and specificity was 75%. The malignant nature of the lesions was determined with a sensitivity of 100% and a specificity of 92%. MRCP "single shot" thick slices could not differentiate pancreatic carcinomas from distal main bile duct cholangiocarcinomas. MRCP single shot" thick slices did not defect small stones (less than or equal to 3 mm) of the the common bile duct. Conclusion - The excellent sensitivity specificity and infer-observer agreement of MRCP "single shot" thick slices can be used to limit invasive imaging methods in the diagnosis of extrahepatic cholestasis.
引用
收藏
页码:888 / 895
页数:8
相关论文
共 50 条
  • [21] Volvulus of the gall bladder diagnosed by ultrasonography,computed tomography,coronal magnetic resonance imaging and magnetic resonance cholangio-pancreatography
    Nobuhisa Matsuhashi
    Shinichi Satake
    Kazunori Yawata
    Eri Asakawa
    Takashi Mizoguchi
    Masayuki Kanematsu
    Hiroshi Kondo
    Ichiro Yasuda
    Kenichi Nonaka
    Chihiro Tanaka
    Atsushi Misao
    Shinji Ogura
    World Journal of Gastroenterology, 2006, (28) : 4599 - 4601
  • [22] MR cholangio-pancreatography (MRCP) using breathhold HASTE (half Fourier acquisition single-shot turbo spin-echo) sequence clinical evaluation in 97 cases
    Naik, KS
    Hockwald, S
    Rofsky, NM
    Krinsky, GA
    Weinreb, JC
    Megibow, AJ
    RADIOLOGY, 1997, 205 : 1525 - 1525
  • [23] Diagnosis of the gallbladder duplication coinciding with a gallbladder carcinoma by magnetic resonance cholangio-pancreatography: A case report
    Zheng, Hailan
    Zheng, Yongfei
    Zhang, Guohua
    Wang, Lubing
    ASIAN JOURNAL OF SURGERY, 2021, 44 (07) : 1012 - 1013
  • [24] Volvulus of the gall bladder diagnosed by ultrasonography, computed tomography, coronal magnetic resonance imaging and magnetic resonance cholangio-pancreatography
    Matsuhashi, Nobuhisa
    Satake, Shinichi
    Yawata, Kazunori
    Asakawa, Eri
    Mizoguchi, Takashi
    Kanematsu, Masayuki
    Kondo, Hiroshi
    Yasuda, Ichiro
    Nonaka, Kenichi
    Tanaka, Chihiro
    Misao, Atsushi
    Ogura, Shinji
    WORLD JOURNAL OF GASTROENTEROLOGY, 2006, 12 (28) : 4599 - 4601
  • [25] Value of the magnetic resonance cholangiopancreatography (MRCP) in the biliary obstruction: Compared with endoscopic retrograde cholangio-pancreatography (ERCP)
    Lozzi, RD
    Jury, RH
    Gadea, OR
    Capiel, C
    Bouzas, C
    GASTROINTESTINAL ENDOSCOPY, 1999, 49 (04) : AB156 - AB156
  • [26] Non-invasive cholangio-pancreatography by breath-hold magnetic resonance imaging: Preliminary results
    Bearcroft, PW
    Gimson, A
    Lomas, DJ
    CLINICAL RADIOLOGY, 1997, 52 (05) : 345 - 350
  • [27] Magnetic Resonance Cholangio-Pancreatography (MRCP) Has a High Negative Predictive Value in Patients Suspected to Have Choledocholithiasis
    Bjornsson, Einar
    Sverrisson, Ingvar
    Hannesson, Petur
    Ivarsson, Bjarki
    Bloendal, Sigurdur
    GASTROENTEROLOGY, 2013, 144 (05) : S256 - S256
  • [28] Magnetic Resonance Cholangio-Pancreatography (MRCP) Has a High Negative Predictive Value in Patients Suspected to Have Choledocholithiasis
    Hjartarson, Jon Halldor
    Hannesson, Petur
    Sverrisson, Ingvar
    Bloendal, Sigurdur
    Bjornsson, Einar
    GASTROENTEROLOGY, 2015, 148 (04) : S290 - S290
  • [29] Cine magnetic resonance imaging with single-shot fast spin echo for evaluation of dysphagia and aspiration
    Hartl, Dana M.
    Kolb, Frederic
    Bretagne, Evelyne
    Marandas, Patrick
    Sigal, Robert
    DYSPHAGIA, 2006, 21 (03) : 156 - 162
  • [30] Cine Magnetic Resonance Imaging with Single-Shot Fast Spin Echo for Evaluation of Dysphagia and Aspiration
    Dana M. Hartl
    Frédéric Kolb
    Evelyne Bretagne
    Patrick Marandas
    Robert Sigal
    Dysphagia, 2006, 21 : 156 - 162