Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses

被引:67
|
作者
Malik, Shaihan J. [1 ]
Keihaninejad, Shiva [2 ]
Hammers, Alexander [3 ]
Hajnal, Joseph V. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Robert Steiner MRI Unit, Imaging Sci Dept,MRC Clin Sci Ctr, London W12 0HS, England
[2] Univ London Imperial Coll Sci Technol & Med, Ctr Neurosci, Div Expt Med, Dept Med, London W12 0HS, England
[3] CERMEP Imagerie Vivant, Neurodis Fdn, Lyon, France
基金
英国工程与自然科学研究理事会;
关键词
parallel transmit; radiofrequency inhomogeneity; MP-RAGE; tailored radiofrequency pulse; REDUCED B-1 INHOMOGENEITY; PARALLEL EXCITATION; SELECTIVE EXCITATION; STEADY-STATE; 8; CHANNELS; BRAIN; FIELD; OPTIMIZATION; DESIGN; MRI;
D O I
10.1002/mrm.23118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k-space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root-mean-square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP-RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1303 / 1315
页数:13
相关论文
共 50 条
  • [31] 3D Printable Embedded RF Connectors
    Reese, Malcolm S.
    Heilman, Grant D.
    Doyle, Derek
    Christodoulou, Christos G.
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 1525 - 1526
  • [32] 3D characterization of RF power transistors
    Arnborg, Torkel
    Johansson, Ted
    IEEE International Conference on Microelectronic Test Structures, 1999, : 131 - 134
  • [33] 3D characterization of RF power transistors
    Arnborg, T
    Johansson, T
    ICMTS 1999: PROCEEDINGS OF THE 1999 INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES, 1999, : 131 - 134
  • [34] A 3D Multilateration Using RF Burst
    Nabila, Haifa
    Suryana, Joko
    Izzuddin, Ahmad
    PROCEEDING OF 2020 6TH INTERNATIONAL CONFERENCE ON WIRELESS AND TELEMATICS (ICWT), 2020,
  • [35] 3D technologies for analog/RF applications
    Vandooren, A.
    Parvais, B.
    Witters, L.
    Walke, A.
    Vais, A.
    Merckling, C.
    Lin, D.
    Waldron, N.
    Wambacq, P.
    Mocuta, D.
    Collaert, N.
    2017 IEEE SOI-3D-SUBTHRESHOLD MICROELECTRONICS TECHNOLOGY UNIFIED CONFERENCE (S3S), 2017,
  • [36] 3D RF Emitter Location Estimation
    Weber, Raymond J.
    Huang, Yikun
    2010 IEEE AEROSPACE CONFERENCE PROCEEDINGS, 2010,
  • [37] Coherence selection and excitation sculpting using RF-gradients in selective 1D experiments and nonselective 2D experiments
    Heikkinen, S
    Rahkamaa, E
    Kilpeläinen, I
    JOURNAL OF MAGNETIC RESONANCE, 1998, 133 (01) : 183 - 189
  • [38] Time-and-energy-resolved measurement of Auger cascades following Kr 3d excitation by attosecond pulses
    Verhoef, A. J.
    Mitrofanov, A. V.
    Nguyen, X. T.
    Krikunova, M.
    Fritzsche, S.
    Kabachnik, N. M.
    Drescher, M.
    Baltuska, A.
    NEW JOURNAL OF PHYSICS, 2011, 13
  • [39] Determination of the 3D dust distribution in spiral galaxies
    Kylafis, ND
    Xilouris, EM
    NEW EXTRAGALACTIC PERSPECTIVES IN THE NEW SOUTH AFRICA, 1996, 209 : 195 - 202
  • [40] 3D structure of gaseous disks in spiral galaxies
    Kovalenko, I. G.
    Eremin, M. A.
    Korolev, V. V.
    ASTROPHYSICAL DISKS: COLLECTIVE AND STOCHASTIC PHENOMENA, 2006, 337 : 231 - +