Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses

被引:67
|
作者
Malik, Shaihan J. [1 ]
Keihaninejad, Shiva [2 ]
Hammers, Alexander [3 ]
Hajnal, Joseph V. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Robert Steiner MRI Unit, Imaging Sci Dept,MRC Clin Sci Ctr, London W12 0HS, England
[2] Univ London Imperial Coll Sci Technol & Med, Ctr Neurosci, Div Expt Med, Dept Med, London W12 0HS, England
[3] CERMEP Imagerie Vivant, Neurodis Fdn, Lyon, France
基金
英国工程与自然科学研究理事会;
关键词
parallel transmit; radiofrequency inhomogeneity; MP-RAGE; tailored radiofrequency pulse; REDUCED B-1 INHOMOGENEITY; PARALLEL EXCITATION; SELECTIVE EXCITATION; STEADY-STATE; 8; CHANNELS; BRAIN; FIELD; OPTIMIZATION; DESIGN; MRI;
D O I
10.1002/mrm.23118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k-space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root-mean-square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP-RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1303 / 1315
页数:13
相关论文
共 50 条
  • [21] The 3D spiral structure pattern in the atmosphere
    Liu, SD
    Xin, GJ
    Liu, SK
    Liang, FM
    ADVANCES IN ATMOSPHERIC SCIENCES, 2000, 17 (04) : 519 - 524
  • [22] Spiral Galaxy in 3D as Seen with SpIOMM
    Rousseau-Nepton, Laurie
    Robert, Carmelle
    Drissen, Laurent
    GALAXIES IN 3D ACROSS THE UNIVERSE, 2014, 10 (309): : 340 - 340
  • [23] Neurologic 3D MR Spectroscopic Imaging with Low-Power Adiabatic Pulses and Fast Spiral Acquisition
    Andronesi, Ovidiu C.
    Gagoski, Borjan A.
    Sorensen, A. Gregory
    RADIOLOGY, 2012, 262 (02) : 647 - 661
  • [24] Magnetic anisotropy of single 3d spins on a CuN surface
    Shick, A. B.
    Maca, F.
    Lichtenstein, A. I.
    PHYSICAL REVIEW B, 2009, 79 (17)
  • [25] Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses
    Mitsouras, D
    Mulkern, RV
    Rybicki, FJ
    MEDICAL PHYSICS, 2006, 33 (01) : 173 - 186
  • [26] X-rays used to watch spins in 3D
    Peter Fischer
    Nature, 2017, 547 : 290 - 291
  • [27] PHASE-SCRAMBLED RF EXCITATION FOR 3D VOLUME-SELECTIVE MULTISLICE NMR IMAGING
    OH, CH
    HILAL, SK
    WU, EX
    CHO, ZH
    MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 290 - 299
  • [28] The design of miniature 3D RF module
    Lähteenmäki, J
    Miettinen, J
    Heino, P
    55TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2005 PROCEEDINGS, 2005, : 814 - 817
  • [29] 3D silicon micromachined RF resonators
    Strohm, KM
    Schmückle, FJ
    Yaglioglu, O
    Luy, JF
    Heinrich, W
    2003 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2003, : 1801 - 1804
  • [30] RF-Based 3D Skeletons
    Zhao, Mingmin
    Tian, Yonglong
    Zhao, Hang
    Abu Alsheikh, Mohammad
    Li, Tianhong
    Hristov, Rumen
    Kabelac, Zachary
    Katabi, Dina
    Torralba, Antonio
    PROCEEDINGS OF THE 2018 CONFERENCE OF THE ACM SPECIAL INTEREST GROUP ON DATA COMMUNICATION (SIGCOMM '18), 2018, : 267 - 281