Tailored excitation in 3D with spiral nonselective (SPINS) RF pulses

被引:67
|
作者
Malik, Shaihan J. [1 ]
Keihaninejad, Shiva [2 ]
Hammers, Alexander [3 ]
Hajnal, Joseph V. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Robert Steiner MRI Unit, Imaging Sci Dept,MRC Clin Sci Ctr, London W12 0HS, England
[2] Univ London Imperial Coll Sci Technol & Med, Ctr Neurosci, Div Expt Med, Dept Med, London W12 0HS, England
[3] CERMEP Imagerie Vivant, Neurodis Fdn, Lyon, France
基金
英国工程与自然科学研究理事会;
关键词
parallel transmit; radiofrequency inhomogeneity; MP-RAGE; tailored radiofrequency pulse; REDUCED B-1 INHOMOGENEITY; PARALLEL EXCITATION; SELECTIVE EXCITATION; STEADY-STATE; 8; CHANNELS; BRAIN; FIELD; OPTIMIZATION; DESIGN; MRI;
D O I
10.1002/mrm.23118
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain images acquired at 3T often display central brightening with spatially varying tissue contrast, caused by inhomogeneity in the transmit radiofrequency fields used for excitation. Tailored radiofrequency pulses can provide mitigation of radiofrequency field inhomogeneity, but previous designs have been unsuitable for 3D imaging in rapid pulse sequences. This article presents a nonselective pulse design based on a short (1 ms) 3D spiral k-space trajectory that covers low spatial frequencies. The resulting excitations are optimized to produce a uniform excitation within a specified volume of interest covering the whole brain. B1 mapping and pulse calculation times were reduced by optimizing in only five slices within the brain. The method has been tested with both single and parallel transmission: in phantom experiments, normalized root-mean-square error in excitation was 0.022 for single and 0.020 for parallel transmission. The corresponding results in vivo were 0.066 and 0.055 respectively. A pilot brain imaging study using the proposed pulses for excitation within the Alzheimer's disease neuroimaging initiative magnetization prepared rapid gradient echo (MP-RAGE) protocol, yielded excellent image quality with improved signal to noise ratio in peripheral brain regions and enhanced uniformity of contrast compared with standard excitation. Greatest performance enhancement was achieved using parallel transmission, but single channel transmission offers significant improvement over standard excitation pulses. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:1303 / 1315
页数:13
相关论文
共 50 条
  • [1] Variable-density spiral 3D tailored RF pulses
    Stenger, VA
    Boada, FE
    Noll, DC
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1100 - 1106
  • [2] Multishot 3D slice-select tailored RF pulses for MRI
    Stenger, VA
    Boada, FE
    Noll, DC
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 157 - 165
  • [3] TAILORED EXCITATION BY SHAPED RF PULSES - OPTIMIZATION AND IMPLEMENTATION OF EXCITATION CONTAINING A NOTCH
    LIU, H
    WEISZ, K
    JAMES, TL
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (02) : 184 - 192
  • [4] Joint Design of RF and Gradient Waveforms via Auto-differentiation for 3D Tailored Excitation in MRI
    Luo, Tianrui
    Noll, Douglas C.
    Fessler, Jeffrey A.
    Nielsen, Jon-Fredrik
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (12) : 3305 - 3314
  • [5] Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI
    Hao, Sun
    Fessler, Jeffrey A.
    Noll, Douglas C.
    Nielsen, Jon-Fredrik
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (02) : 468 - 479
  • [6] Excitation UNFOLD (XUNFOLD) to improve the temporal resolution of multishot tailored RF pulses
    Stenger, V. Andrew
    Giurgi, Marius S.
    Boada, Fernando E.
    Noll, Douglas C.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) : 692 - 697
  • [7] Reproducibility of tailored and universal nonselective excitation pulses at 7 T for human cardiac MRI: A 3-year and an interday study
    Alarcon, Manuel Fernando Sanchez
    Dietrich-Conzelmann, Sebastian
    Bassenge, Jean Pierre
    Schulz-Menger, Jeanette
    Schmitter, Sebastian
    Aigner, Christoph Stefan
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [8] Tailored and universal parallel transmit broadband pulses for homogeneous 3D excitation of the human heart at 7T
    Aigner, Christoph Stefan
    Dietrich-Conzelmann, Sebastian
    Lutz, Max
    Krueger, Felix
    Schmitter, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 730 - 740
  • [9] The Natural 3D Spiral
    Harary, Gur
    Tal, Ayellet
    COMPUTER GRAPHICS FORUM, 2011, 30 (02) : 237 - 246
  • [10] Anodic 3D nanostructuring for tailored applications
    Moyen, Eric
    Santinacci, Lionel
    Masson, Laurence
    Sahaf, Houda
    Mace, Magali
    Assaud, Loic
    Hanbuecken, Margrit