Point dose calculations using an analytical pencil beam kernel for IMRT plan checking

被引:15
|
作者
Watanabe, Y [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Radiat Oncol, New York, NY 10032 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 04期
关键词
D O I
10.1088/0031-9155/46/4/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.
引用
收藏
页码:1031 / 1038
页数:8
相关论文
共 50 条
  • [41] A new concept of pencil beam dose calculation for 40-200 keV photons using analytical dose kernels
    Bartzsch, Stefan
    Oelfke, Uwe
    MEDICAL PHYSICS, 2013, 40 (11)
  • [42] Monte Carlo Versus Pencil Beam Dose Calculation for Spine SBRT Treatments Using HybridARC and Sliding Windows IMRT
    Venencia, C.
    Pino, M.
    Caussa, L.
    Molineu, A.
    Garrigo, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3549 - +
  • [43] LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN THE HEAD AND NECK REGION
    HURKMANS, C
    KNOOS, T
    NILSSON, P
    SVAHNTAPPER, G
    DANIELSSON, H
    RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) : 74 - 80
  • [44] Electron pencil-beam redefinition algorithm dose calculations in the presence of heterogeneities
    Boyd, RA
    Hogstrom, KR
    Starkschall, G
    MEDICAL PHYSICS, 2001, 28 (10) : 2096 - 2104
  • [45] LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN LUNG-TISSUE
    KNOOS, T
    AHNESJO, A
    NILSSON, P
    WEBER, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09): : 1411 - 1420
  • [46] VERIFICATION OF PHOTON DOSE CALCULATION ACCURACY BY THE PENCIL BEAM AND ANALYTICAL ANISOTROPIC ALGORITHM USING MOSFET DETECTORS
    Swinnen, A.
    Nulens, A.
    Verstraete, J.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S414 - S414
  • [47] The effects of divergence and nonuniformity on the x-ray pencil-beam dose kernel
    Ceberg, CP
    Bjarngard, BE
    MEDICAL PHYSICS, 1996, 23 (09) : 1531 - 1535
  • [48] Pencil kernel correction and residual error estimation for quality-index-based dose calculations
    Nyholm, Tufve
    Olofsson, Jorgen
    Ahnesjo, Anders
    Georg, Dietmar
    Karlsson, Mikael
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23): : 6245 - 6262
  • [49] Application of the Dose Point Kernel Method for Nanoscale Dose Calculations Around Gold Nanoparticles
    Jayarathna, S.
    Manohar, N.
    Ahmed, M.
    Cho, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2987 - 2987
  • [50] Strip-beam electron pencil-beam redefinition dose calculations for modulated electron therapy
    Boyd, R
    Antolak, J
    Hogstrom, K
    MEDICAL PHYSICS, 2003, 30 (06) : 1447 - 1447