摘要
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.
引用
收藏
页码:1031 / 1038
页数:8
相关论文
共 50 条
  • [21] OPTIMIZATION OF PENCIL BEAM WIDTHS FOR ELECTRON-BEAM DOSE CALCULATIONS - RESPONSE
    ANTOLAK, JA
    MEDICAL PHYSICS, 1995, 22 (09) : 1443 - 1443
  • [22] OPTIMIZATION OF PENCIL BEAM WIDTHS FOR ELECTRON-BEAM DOSE CALCULATIONS - COMMENT
    WERNER, BL
    MEDICAL PHYSICS, 1995, 22 (09) : 1441 - 1441
  • [23] Evaluation of IMRT Dose Calculation Based On Pencil-Beam and AAA Algorithms
    Yuan, Y.
    Duan, J.
    Popple, R.
    Brezovich, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3829 - 3829
  • [24] The use of modified single pencil beam dose kernels to improve IMRT dose calculation accuracy
    Bergman, AM
    Otto, K
    Duzenli, C
    MEDICAL PHYSICS, 2004, 31 (12) : 3279 - 3287
  • [25] A finite size pencil beam algorithm for IMRT dose optimization: density corrections
    Jelen, U.
    Alber, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03): : 617 - 633
  • [26] Dose Kernel of 6 MV FFF Beam in TrueBeam for Pencil Beam Convolution Algorithms
    Tang, G.
    Georgiev, G.
    Lim, S.
    Lovelock, D.
    LoSasso, T.
    Kirov, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Dose uncertainties in photon pencil kernel calculations at off-axis positions
    Olofsson, Jorgen
    Nyholm, Tufve
    Ahnesjo, Anders
    Karlsson, Mikael
    MEDICAL PHYSICS, 2006, 33 (09) : 3418 - 3425
  • [28] Additional dose constraints for analytical beam weighting optimization in IMRT
    Arráns, R
    Gallardo, MI
    Roselló, J
    Sánchez-Doblado, F
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) : 224 - 226
  • [29] A generic computer program for checking photon beam dose calculations
    Redpath, AT
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (912): : 904 - 908
  • [30] Range-modulated pencil beam algorithm for proton dose calculations
    Kohno, R
    Takada, Y
    Sakae, T
    Nohtomi, A
    Terunuma, T
    Matsumoto, K
    Matsuda, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (08): : 5187 - 5193