Point dose calculations using an analytical pencil beam kernel for IMRT plan checking

被引:15
|
作者
Watanabe, Y [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Radiat Oncol, New York, NY 10032 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 04期
关键词
D O I
10.1088/0031-9155/46/4/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is different from the method used for the treatment plan. Our approach uses a convolution algorithm and an analytical pencil beam kernel with eight parameters. The model is intuitive and simple. At the same time, the method is so general that it can be applied to both step-and-shoot and sliding-window techniques. The results of applications to actual treatment plans show that the calculated total isocentre doses are accurate within +/-2% of planned doses for six-field prostate plans when calculation points are in a uniform dose region. Head and neck cases show a slightly larger difference than prostate cases. When calculation points are located in a region of high dose gradient, however, the difference could be greater than 5%.
引用
收藏
页码:1031 / 1038
页数:8
相关论文
共 50 条
  • [1] 'A finite size pencil beam for IMRT dose optimization' - a simpler analytical function for the finite size pencil beam kernel
    Lin, H
    Wu, YC
    Chen, YX
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : L13 - L15
  • [2] FAST PENCIL KERNEL DOSE CALCULATIONS FOR PHOTON BEAMS USING INTERPOLATION IN THE PENCIL KERNEL PARAMETER SPACE
    Eriksson, D.
    Ahnesjo, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S114 - S114
  • [3] Improved IMRT dose calculations using pencil beam kernels derived from high resolution film dosimetry
    Otto, K
    Alkins, R
    Clark, BG
    MEDICAL PHYSICS, 2003, 30 (07) : 1944 - 1944
  • [4] Modelling lateral beam quality variations in pencil kernel based photon dose calculations
    Nyholm, T.
    Olofsson, J.
    Ahnesjo, A.
    Karlsson, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16): : 4111 - 4118
  • [5] A finite size Pencil Beam algorithm for IMRT dose optimization based on Monte Carlo calculations
    Jelen, U
    Söhn, M
    Alber, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S95 - S95
  • [6] A finite size pencil beam for IMRT dose optimization
    Jelen, U
    Söhn, M
    Alber, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08): : 1747 - 1766
  • [7] Clinical applications of a dose calculation algorithm with analytic pencil beam kernel to IMRT patient specific QA
    Watanabe, Y
    Wuu, C
    Kutcher, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1868 - 1868
  • [8] A pencil beam algorithm for proton dose calculations
    Hong, L
    Goitein, M
    Bucciolini, M
    Comiskey, R
    Gottschalk, B
    Rosenthal, S
    Serago, C
    Urie, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1305 - 1330
  • [9] EVALUATION OF ELECTRON PENCIL BEAM DOSE CALCULATIONS
    HOGSTROM, KR
    MEDICAL PHYSICS, 1985, 12 (04) : 554 - 554
  • [10] Improved dose accuracy for plan checking IMRT breast plans
    Corns, R.
    Thomas, S.
    Dubrowski, P.
    Huang, V.
    Shahine, I.
    MEDICAL PHYSICS, 2012, 39 (07) : 4638 - 4638