Development of a dose-rate dosimeter for x-ray CT scanner using silicon x-ray diode

被引:4
|
作者
Yamaguchi, Satoshi [1 ]
Sato, Eiichi [2 ]
Ieko, Yoshiro [3 ]
Ariga, Hisanori [3 ]
Yoshioka, Kunihiro [3 ]
机构
[1] Iwate Med Univ, Sch Med, Dept Radiol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
[2] Iwate Med Univ, Dept Phys, 1-1-1 Idaidori, Yahaba, Iwate 0283694, Japan
[3] Iwate Med Univ, Iwate Med Univ Hosp, Dept Radiat Oncol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 05期
关键词
DUAL-ENERGY CT; SETUP; HEAD;
D O I
10.1063/5.0047546
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In an x-ray diagnosis, it is important to evaluate the entrance dose rate, as the dose rate of exposure becomes highest in that position. To investigate the effect of the entrance dose rate of x-ray CT scanners, a dose-rate dosimeter comprising a silicon x-ray diode (Si-XD), a CMOS dual operational amplifier, resistors, capacitors, and a mini-substrate measuring 20 x 17 mm(2) were developed. The Si-XD is desirable for measuring the changing entrance dose rate, as it enables the reduction of the response time, dimensions, and cost of the dosimeter. The dosimeter was connected to a microcomputer (mbed), and the output voltages from the dosimeter were measured using an analog-digital converter in the mbed. The output voltages were proportional to the tube currents at a constant tube voltage of 100 kV using an industrial x-ray tube, and the calibrated dose rates corresponded well to those obtained using a commercially available semiconductor dosimeter. However, owing to the energy dependence of the dosimeter, the calibrated dose rate was similar to 10% higher than that of a commercially available semiconductor dosimeter at the lower tube voltage. In the angular dependence of the dosimeter, the flatness measured from 60 degrees to 120 degrees was similar to 103% in this study. A fundamental study for measuring the dose-rate variations with rotation was performed. The results showed a different profile than the angular dependence due to the distance from the source and the complex factors of the scattered radiation. Published under license by AIP Publishing.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [31] A SECONDARY STANDARD PROTECTION-LEVEL X-RAY DOSE-RATE METER
    READ, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 132 - &
  • [32] X-RAY ANGULAR SCANNER AND ITS APPLICATION TO X-RAY IMAGING.
    Protopopov, V. V.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1996, 52 : C496 - C496
  • [33] Development of X-ray mirrors for X-ray telescopes
    Tamura, Keisuke
    Sakai, Chiaki
    Yamada, Nubuaki
    Ogasaka, Yasushi
    Shibata, Ryo
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY II, 2005, 5900
  • [34] DOSE-RATE FIELD OF THE HERMES-III FLASH X-RAY SOURCE
    SANFORD, TWL
    HALBLEIB, JA
    MOCK, RC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (06) : 1762 - 1768
  • [35] Development of X-ray diode with high performance
    Hou L.
    Yang G.
    Liu S.
    Wei M.
    Yi T.
    Jiang S.
    Sun K.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2011, 23 (03): : 652 - 656
  • [36] Evaluation of the MOSkin dosimeter for diagnostic X-ray CT beams
    Pereira, L. Mendes
    Khoury, H. J.
    Andrade, M. E. A.
    Barros, V. S. M.
    Cutajar, D.
    Rosenfeld, A. B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 150 - 155
  • [37] Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
    Zappala, Susan
    Helliwell, Jonathan R.
    Tracy, Saoirse R.
    Mairhofer, Stefan
    Sturrock, Craig J.
    Pridmore, Tony
    Bennett, Malcolm
    Mooney, Sacha J.
    PLOS ONE, 2013, 8 (06):
  • [38] VACUUM X-RAY DIODE
    GANEEV, AS
    ZAPYSOV, AL
    IZRAILEV, IM
    NIKITIN, VP
    PODGORNOV, VA
    KHAVRONIN, NA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (03) : 725 - 726
  • [39] Development of High-speed X-ray CT Inspection System Using X-ray Line Sensor
    Suzuki, Daisuke
    Noguchi, Kenji
    Murakoshi, Takayuki
    Teramoto, Atsushi
    2013 IEEE 3RD CPMT SYMPOSIUM JAPAN (ICSJ 2013), 2013,
  • [40] SIMULTANEOUS EMISSION CT AND X-RAY TRANSMISSION CT USING COMPOSITE X-RAY AND GAMMA-RAY DETECTORS
    CLINTHORNE, NH
    ANTONUK, LE
    HUANG, W
    YORKSTON, J
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P100 - P101