Development of a dose-rate dosimeter for x-ray CT scanner using silicon x-ray diode

被引:4
|
作者
Yamaguchi, Satoshi [1 ]
Sato, Eiichi [2 ]
Ieko, Yoshiro [3 ]
Ariga, Hisanori [3 ]
Yoshioka, Kunihiro [3 ]
机构
[1] Iwate Med Univ, Sch Med, Dept Radiol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
[2] Iwate Med Univ, Dept Phys, 1-1-1 Idaidori, Yahaba, Iwate 0283694, Japan
[3] Iwate Med Univ, Iwate Med Univ Hosp, Dept Radiat Oncol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 05期
关键词
DUAL-ENERGY CT; SETUP; HEAD;
D O I
10.1063/5.0047546
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In an x-ray diagnosis, it is important to evaluate the entrance dose rate, as the dose rate of exposure becomes highest in that position. To investigate the effect of the entrance dose rate of x-ray CT scanners, a dose-rate dosimeter comprising a silicon x-ray diode (Si-XD), a CMOS dual operational amplifier, resistors, capacitors, and a mini-substrate measuring 20 x 17 mm(2) were developed. The Si-XD is desirable for measuring the changing entrance dose rate, as it enables the reduction of the response time, dimensions, and cost of the dosimeter. The dosimeter was connected to a microcomputer (mbed), and the output voltages from the dosimeter were measured using an analog-digital converter in the mbed. The output voltages were proportional to the tube currents at a constant tube voltage of 100 kV using an industrial x-ray tube, and the calibrated dose rates corresponded well to those obtained using a commercially available semiconductor dosimeter. However, owing to the energy dependence of the dosimeter, the calibrated dose rate was similar to 10% higher than that of a commercially available semiconductor dosimeter at the lower tube voltage. In the angular dependence of the dosimeter, the flatness measured from 60 degrees to 120 degrees was similar to 103% in this study. A fundamental study for measuring the dose-rate variations with rotation was performed. The results showed a different profile than the angular dependence due to the distance from the source and the complex factors of the scattered radiation. Published under license by AIP Publishing.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [21] X-RAY CT SCANNER FOR HEAVY AND VALUABLE COMPONENTS
    TANIMOTO, Y
    MATSUURA, S
    FUJII, M
    MANIWA, T
    TOSHIBA REVIEW, 1987, (160): : 13 - 17
  • [22] DEVELOPMENT OF X-RAY SILICON MICROCALORIMETERS
    Agnese, P.
    Aliane, A.
    Gasse, A.
    Demoro, F.
    Gobil, Y.
    Ballerand, S.
    Beccia, C.
    Borel, I.
    Goupy, J.
    Ribot, H.
    Pigot, C.
    Sauvageot, J. -L.
    Szeflinski, V.
    Perot, F.
    Gremion, E.
    de la Brose, X.
    Navick, X-F.
    ASTROPHYSICS DETECTOR WORKSHOP 2008, 2009, 37 : 89 - 93
  • [23] Determination and verification of the x-ray spectrum of a CT scanner
    Hassan, Ahmad Ibrahim
    Skalej, Martin
    Schlattl, Helmut
    Hoeschen, Christoph
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [24] A SIMPLE CONVERSION OF AN X-RAY DOSE-RATE METER INTO AN INTEGRATING DOSE-METER
    SMITH, CL
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1952, 29 (08): : 269 - 270
  • [25] DEVELOPMENT OF A GEL TYPE DOSIMETER FOR X-RAY FIELDS
    Aoki, Yutaro
    Harvel, Glenn
    Sakura, Toshiharu
    Sunagawa, Takeyoshi
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 9, 2017,
  • [26] Evaluation of scintillation detectors for ultrahigh dose-rate x-ray beam dosimetry
    Shaharuddin, Shahirah
    Hart, Alexander
    Bazalova-Carter, Magdalena
    Beaulieu, Luc
    Giguere, Cloe
    Kleefeld, Christoph
    Foley, Mark
    OPTICAL SENSING AND DETECTION VII, 2022, 12139
  • [27] Design of an X-ray irradiator with FLASH dose-rate capabilities for preclinical research
    Ibanez, P.
    Espinosa-Rodriguez, A.
    Villa-Abaunza, A.
    Sanchez-Parcerisa, D.
    Diaz, N.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1579 - S1580
  • [28] A portable indicating x-ray dosimeter
    Krebs, RP
    Kersten, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1942, 13 (08): : 332 - 334
  • [29] THE GEIGER COUNTER AS AN X-RAY DOSIMETER
    FULLER, WF
    BLESS, AA
    PHYSICAL REVIEW, 1946, 69 (9-10): : 545 - 545
  • [30] AN OXYGEN-DEPENDENT X-RAY DOSE-RATE EFFECT IN SERRATIA MARCESCENS
    DEWEY, DL
    RADIATION RESEARCH, 1969, 38 (03) : 467 - &