Development of a dose-rate dosimeter for x-ray CT scanner using silicon x-ray diode

被引:4
|
作者
Yamaguchi, Satoshi [1 ]
Sato, Eiichi [2 ]
Ieko, Yoshiro [3 ]
Ariga, Hisanori [3 ]
Yoshioka, Kunihiro [3 ]
机构
[1] Iwate Med Univ, Sch Med, Dept Radiol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
[2] Iwate Med Univ, Dept Phys, 1-1-1 Idaidori, Yahaba, Iwate 0283694, Japan
[3] Iwate Med Univ, Iwate Med Univ Hosp, Dept Radiat Oncol, 2-1-1 Idaidori, Yahaba, Iwate 0283695, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2021年 / 92卷 / 05期
关键词
DUAL-ENERGY CT; SETUP; HEAD;
D O I
10.1063/5.0047546
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In an x-ray diagnosis, it is important to evaluate the entrance dose rate, as the dose rate of exposure becomes highest in that position. To investigate the effect of the entrance dose rate of x-ray CT scanners, a dose-rate dosimeter comprising a silicon x-ray diode (Si-XD), a CMOS dual operational amplifier, resistors, capacitors, and a mini-substrate measuring 20 x 17 mm(2) were developed. The Si-XD is desirable for measuring the changing entrance dose rate, as it enables the reduction of the response time, dimensions, and cost of the dosimeter. The dosimeter was connected to a microcomputer (mbed), and the output voltages from the dosimeter were measured using an analog-digital converter in the mbed. The output voltages were proportional to the tube currents at a constant tube voltage of 100 kV using an industrial x-ray tube, and the calibrated dose rates corresponded well to those obtained using a commercially available semiconductor dosimeter. However, owing to the energy dependence of the dosimeter, the calibrated dose rate was similar to 10% higher than that of a commercially available semiconductor dosimeter at the lower tube voltage. In the angular dependence of the dosimeter, the flatness measured from 60 degrees to 120 degrees was similar to 103% in this study. A fundamental study for measuring the dose-rate variations with rotation was performed. The results showed a different profile than the angular dependence due to the distance from the source and the complex factors of the scattered radiation. Published under license by AIP Publishing.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] A PORTABLE X-RAY SPECTROMETER DOSIMETER BASED ON A SILICON DIODE
    EISEN, Y
    OLSHER, RH
    BRAKE, RJ
    LITTLEJOHN, GJ
    MEDDLES, A
    RADIATION PROTECTION DOSIMETRY, 1990, 32 (02) : 105 - 112
  • [2] Development of X-ray scanner using 450-kVp X-ray
    Kwak, SW
    Kim, KH
    Kim, I
    Cho, GS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) : 2414 - 2419
  • [3] SIMULATION OF HIGH DOSE-RATE X-RAY EFFECTS
    HUNTINGTON, JH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 16 (JUN): : 357 - 357
  • [4] Characterization of an under-development capacitor dosimeter equipped with a silicon x-ray diode
    Yamaguchi, Satoshi
    Ieko, Yoshiro
    Ariga, Hisanori
    Yoshioka, Kunihiro
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (12):
  • [5] INDUSTRIAL X-RAY CT SCANNER
    MATSUURA, S
    TANIMOTO, Y
    MATERIALS EVALUATION, 1985, 43 (10) : 1322 - 1322
  • [6] The IMD-01 miniature portable X-ray dosimeter for monitoring dose rate in X-ray diagnosis
    Vladimirov L.V.
    Kozlov A.A.
    Biomedical Engineering, 2002, 36 (5) : 264 - 267
  • [7] DER-01M Miniature Portable X-Ray Dosimeter for Monitoring Dose and Dose Rate in X-Ray Diagnosis
    L. V. Vladimirov
    A. A. Kozlov
    Biomedical Engineering, 2003, 37 (5) : 295 - 298
  • [8] A swallowable X-ray dosimeter
    Archambault, Louis
    NATURE BIOMEDICAL ENGINEERING, 2023, 7 (10) : 1212 - 1214
  • [9] A swallowable X-ray dosimeter
    Louis Archambault
    Nature Biomedical Engineering, 2023, 7 : 1212 - 1214
  • [10] EFFECT OF DOSE-RATE AND FRACTIONATION OF X-RAY DOSE ON ACUTE LETHALITY IN MICE
    BROWN, JAH
    CORP, MJ
    WESTGARTH, DR
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY AND RELATED STUDIES IN PHYSICS CHEMISTRY AND MEDICINE, 1960, 2 (04): : 371 - 381