Influence of cuff pressures of automatic sphygmomanometers on pulse oximetry measurements

被引:4
|
作者
Sondej, Tadeusz [1 ]
Zawadzka, Sylwia [1 ]
机构
[1] Mil Univ Technol, Fac Elect, Warsaw, Poland
关键词
Blood oxygen saturation; Pulse oximeter; Blood pressure monitor; Photoplethysmography; Physiological parameters; Measurement accuracy; PHOTOPLETHYSMOGRAPHY;
D O I
10.1016/j.measurement.2021.110329
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Information about blood arterial oxygen saturation (SpO(2)) is crucial in critical care settings or home health monitoring during the COVID-19 pandemic. Also, we need to identify the factors that affect the SpO(2) measurement. In this paper, the effect of compression of the cuff during noninvasive blood pressure (NIBP) measurement on the SpO(2) results was investigated. A custom-made system was used for simultaneous measurement of NIBP and SpO(2). The study was conducted on 213 subjects aged between 21 and 93, with a systolic blood pressure of (94 to 194) mmHg, diastolic blood pressure of (52-98) mmHg, and 994 NIBP readings were used for the analysis. During the NIBP measurement, momentary changes in SpO(2) can reach +/- 17% and are in most cases positive (mean 2.9%). The change was not correlated with sex, age, height, body weight, BMI, HR and blood pressure. The obtained results show that frequent NIBP measurements may lead to wrong conclusions about SpO(2). In our study, pressure measurements mainly caused the increase of blood oxygenation level.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Influence of temperature on accuracy of pulse oximetry measurements
    Nowocien, Sylwester
    Mroczka, Janusz
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (10): : 289 - 292
  • [2] Influence of blood pulsation on diagnostic volume in pulse oximetry and photoplethysmography measurements
    Dremin, Viktor
    Zherebtsov, Evgeny
    Bykov, Alexander
    Popov, Alexey
    Doronin, Alexander
    Meglinski, Igor
    APPLIED OPTICS, 2019, 58 (34) : 9398 - 9405
  • [3] Dedicated Chip for Pulse Oximetry Measurements
    Kolacinski, Cezary
    Wasowski, Jerzy
    Szymanski, Andrzej
    Jarosz, Adam
    Kurjata-Pfitzner, Ewa
    Borejko, Tomasz
    Siwiec, Krzysztof
    Pleskacz, Witold A.
    PROCEEDINGS OF 2016 IEEE EAST-WEST DESIGN & TEST SYMPOSIUM (EWDTS), 2016,
  • [4] Pulse oximetry and PPG measurements in plastic surgery
    Pickett, J
    Amoroso, P
    Nield, DV
    Jones, DP
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2330 - 2332
  • [5] Accuracy of fetal pulse oximetry and pitfalls in measurements
    Nijland, R
    Jongsma, HW
    Nijhuis, JG
    Oeseburg, B
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S21 - S27
  • [6] REFLECTANCE PULSE OXIMETRY MEASUREMENTS FROM THE RETINAL FUNDUS
    DEKOCK, JP
    TARASSENKO, L
    GLYNN, CJ
    HILL, AR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (08) : 817 - 823
  • [7] Pulse oximetry measurements during hyperkapnia on animals with RDS
    Engelmann, A
    Pohlandt, F
    Hummler, HD
    PEDIATRIC RESEARCH, 2003, 53 (04) : 48A - 48A
  • [8] Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients
    Van Ginderdeuren, Filip
    Van Cauwelaert, Karlien
    Malfroot, Anne
    JOURNAL OF CYSTIC FIBROSIS, 2006, 5 (02) : 125 - 128
  • [9] Development of a luminous textile for reflective pulse oximetry measurements
    Krehel, Marek
    Wolf, Martin
    Boesel, Luciano F.
    Rossi, Rene M.
    Bona, Gian-Luca
    Scherer, Lukas J.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (08): : 2537 - 2547
  • [10] Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry
    Jamali, Haya
    Castillo, Lauren T.
    Morgan, Chelsea Cosby
    Coult, Jason
    Muhammad, Janice L.
    Osobamiro, Oyinkansola O.
    Parsons, Elizabeth C.
    Adamson, Rosemary
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2022, 19 (12) : 1951 - 1964