Influence of cuff pressures of automatic sphygmomanometers on pulse oximetry measurements

被引:4
|
作者
Sondej, Tadeusz [1 ]
Zawadzka, Sylwia [1 ]
机构
[1] Mil Univ Technol, Fac Elect, Warsaw, Poland
关键词
Blood oxygen saturation; Pulse oximeter; Blood pressure monitor; Photoplethysmography; Physiological parameters; Measurement accuracy; PHOTOPLETHYSMOGRAPHY;
D O I
10.1016/j.measurement.2021.110329
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Information about blood arterial oxygen saturation (SpO(2)) is crucial in critical care settings or home health monitoring during the COVID-19 pandemic. Also, we need to identify the factors that affect the SpO(2) measurement. In this paper, the effect of compression of the cuff during noninvasive blood pressure (NIBP) measurement on the SpO(2) results was investigated. A custom-made system was used for simultaneous measurement of NIBP and SpO(2). The study was conducted on 213 subjects aged between 21 and 93, with a systolic blood pressure of (94 to 194) mmHg, diastolic blood pressure of (52-98) mmHg, and 994 NIBP readings were used for the analysis. During the NIBP measurement, momentary changes in SpO(2) can reach +/- 17% and are in most cases positive (mean 2.9%). The change was not correlated with sex, age, height, body weight, BMI, HR and blood pressure. The obtained results show that frequent NIBP measurements may lead to wrong conclusions about SpO(2). In our study, pressure measurements mainly caused the increase of blood oxygenation level.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] THE INFLUENCE OF PATENT-BLUE-V ON PULSE OXIMETRY AND HAEMOXIMETRY
    LARSEN, VH
    FREUDENDALPEDERSEN, A
    FOGHANDERSEN, N
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 : 53 - 55
  • [32] SKIN REFLECTANCE PULSE OXIMETRY - INVIVO MEASUREMENTS FROM THE FOREARM AND CALF
    MENDELSON, Y
    MCGINN, MJ
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (01): : 7 - 12
  • [33] Effect of Glittered Nail Polish on Pulse Oximetry Measurements in Healthy Subjects
    Yeganehkhah, Mohammadreza
    Dadkhahtehrani, Tahmineh
    Bagheri, AhmadReza
    Kachoie, Ahmad
    IRANIAN JOURNAL OF NURSING AND MIDWIFERY RESEARCH, 2019, 24 (01) : 25 - 29
  • [34] THE EFFECT OF CARBOXYHEMOGLOBIN ON PULSE-OXIMETRY OXYGEN-SATURATION MEASUREMENTS
    PANACEK, EA
    JOURILLES, NJ
    SHERMAN, BW
    RUTHERFORD, WF
    CLINICAL RESEARCH, 1991, 39 (02): : A421 - A421
  • [35] INFLUENCE OF SENSOR SITE LOCATION ON PULSE OXIMETRY KINETICS IN CHILDREN
    REYNOLDS, LM
    NICOLSON, SC
    STEVEN, JM
    ESCOBAR, A
    MCGONIGLE, ME
    JOBES, DR
    ANESTHESIA AND ANALGESIA, 1993, 76 (04): : 751 - 754
  • [36] Automatic discrimination between obstructive and central sleep apnea using pulse oximetry
    Holleboom, Minke
    Fabius, Timon
    Eijsvogel, Michiel
    Van der Palen, Job
    De Jongh, Frans
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [37] AUTOMATIC VAPOR PRESSURE MEASUREMENTS AT MODERATELY HIGH PRESSURES
    SPAUSCHUS, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (12): : 1297 - &
  • [38] RACIAL DIFFERENCES IN PULSE OXIMETRY ACCURACY: PAIRED MEASUREMENTS IN MECHANICALLY VENTILATED PATIENTS
    Gomaa, Dina
    Smith, Maia
    Blakeman, Thomas
    Goodman, Michael
    Branson, Richard D.
    CHEST, 2023, 164 (04) : 1685A - 1686A
  • [39] Determination of Relaxed and Hypoventilation Body Conditions Using Pulse Oximetry and Temperature Measurements
    Billones, Robert Kerwin C.
    Belen, Miguel Guerrero Z.
    Lee, Brent Joseph P.
    Salud, Nathan T.
    Sergio, Roxanne C.
    Tamayo, Gayle R.
    Vicerra, Ryan Rhay P.
    Dadios, Elmer P.
    2020 IEEE 12TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT, AND MANAGEMENT (HNICEM), 2020,
  • [40] Unexpectedly low pulse oximetry measurements associated with variant hemoglobins: A systematic review
    Verhovsek, Madeleine
    Henderson, Matthew P. A.
    Cox, Gerard
    Luo, Hong-yuan
    Steinberg, Martin H.
    Chui, David H. K.
    AMERICAN JOURNAL OF HEMATOLOGY, 2010, 85 (11) : 882 - 885