Angiographic contrast mechanism comparison between Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) sequence and Time of Flight (TOF) sequence for intracranial artery

被引:9
|
作者
Zhang, Qiang [1 ]
Chen, Zhensen [2 ]
Chen, Shuo [1 ]
Liu, Xinke [3 ]
Ning, Jia [1 ]
Han, Yongjun [1 ,4 ,5 ]
Chen, Li [2 ]
He, Le [1 ]
Zhao, Xihai [1 ]
Xiong, Yuhui [1 ]
Guo, Hua [1 ]
Yuan, Chun [2 ]
Li, Rui [1 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res, Sch Med, Dept Biomed Engn, Beijing, Peoples R China
[2] Univ Washington, Dept Radiol, Vasc Imaging Lab, Seattle, WA 98195 USA
[3] Capital Med Univ, Beijing TianTan Hosp, Beijing Neuroradiol Inst, Dept Intervent Neuroradiol, Beijing, Peoples R China
[4] Capital Med Univ, Beijing Inst Brain Disorders, Beijing, Peoples R China
[5] Capital Med Univ, Collaborat Innovat Ctr Brain Disorders, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
TOF; SNAP; MRA contrast mechanism; Blood velocity; SIMULTANEOUS NONCONTRAST ANGIOGRAPHY; ENHANCED MR-ANGIOGRAPHY; MAGNETIZATION-TRANSFER; BLOOD-FLOW; STENOSIS;
D O I
10.1016/j.mri.2019.09.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To theoretically compare the MR angiography (MRA) contrast mechanism of Time of Flight (TOF) and Simultaneous Non-contrast Angiography and intraPlaque hemorrhage (SNAP) for intracranial artery imaging with in-vivo validation. Methods: The contrast ratio (CR) of SNAP and TOF was simulated under different blood velocities and travel distance that the blood had flown through. The CR and the slope of CR with respect to blood velocity of SNAP and TOF were compared in theoretical simulation. Two healthy subjects (a 60 years old female and a 29 years old male) were imaged on a 3 T MR scanner with SNAP, TOF and phase contrast (PC) images as the validation set. The measured CR from the images in validation set was compared with the theoretically simulated CR by Person's correlation coefficient. The ratio of CR difference to velocity difference in the validation set was compared between TOF and SNAP with Student's t-test. Thirty patients (21 males, age: 48 +/- 13.8 years) with carotid artery atherosclerotic plaque were imaged with both TOF and SNAP as the comparison test. Between TOF and SNAP, the CR and total artery length were compared with Student's t-test, and the prevalence of stenosis was compared with Cohen's kappa in comparison test. Results: The theoretically simulated CR was significantly correlated with in-vivo measured CR from the validation set for TOF (p < 0.001) and SNAP (p < 0.001). The simulation revealed that the CR of SNAP was higher than that of TOF when the blood velocity and travel distance were within the range to have effective MRA contrast. Similarly, the in-vivo comparison test showed that SNAP had higher CR (p < 0.001 for all tested intracranial arteries) and longer total artery length (1.4 +/- 0.4 m vs 1.2 +/- 0.2 m, p < 0.001) than TOF. The stenosis detection performance was similar between TOF and SNAP (Cohen's kappa 0.72; 95% confidence interval: 0.51-0.93). Moreover, compared with TOF, SNAP showed higher slope of CR with respect to velocity in simulation (0.06 +/- 0.02 s/cm vs 0.02 +/- 0.05 s/cm, p < 0.001), and higher ratio of CR difference to velocity difference in validation test (0.47 +/- 0.38 s/cm vs 0.19 +/- 0.38 s/cm, p = 0.001). Conclusions: Compared with TOF, the SNAP shows better performance to visualize distal intracranial artery and worse performance to visualize ICA, and is more sensitive to blood velocity.
引用
下载
收藏
页码:199 / 207
页数:9
相关论文
共 29 条
  • [21] Contrast-enhanced MR angiography in patients with carotid artery stenosis: comparison of two different techniques with an unenhanced 2D time-of-flight sequence
    H. R. Jäger
    E. A. Moore
    M. Bynevelt
    S. Coley
    P. Mounfield
    N. Kitchen
    W. Taylor
    Neuroradiology, 2000, 42 : 240 - 248
  • [22] Contrast-enhanced MR angiography in patients with carotid artery stenosis:: comparison of two different techniques with an unenhanced 2D time-of-flight sequence
    Jäger, HR
    Moore, EA
    Bynevelt, M
    Coley, S
    Mounfield, P
    Kitchen, N
    Taylor, W
    NEURORADIOLOGY, 2000, 42 (04) : 240 - 248
  • [23] Comparison of non-contrast vessel wall imaging and 3-D time-of-flight MRA for atherosclerotic stenosis and plaque characterization within intracranial arteries
    Kim, Dong Kun
    Verdoorn, Jared T.
    Gunderson, Tina M.
    Huston, John, III
    Brinjikji, Waleed
    Lanzino, Giuseppe
    Lehman, Vance T.
    JOURNAL OF NEURORADIOLOGY, 2020, 47 (04) : 266 - 271
  • [24] The current role of 1.5T non-contrast 3D time-of-flight magnetic resonance angiography to detect intracranial Steno-occlusive disease
    Sadikin, Cindy
    Teng, Michael Mu-Huo
    Chen, Ting-Yi
    Luo, Chao-Bao
    Chang, Feng-Chi
    Lirng, Jiing-Feng
    Sun, Ying-Chou
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2007, 106 (09) : 691 - 699
  • [25] Pre-Procedural Assessment of the Femoral Access Route for Transcatheter Aortic Valve Implantation: Comparison of a Non-Contrast Time-of-Flight Magnetic Resonance Angiography Protocol with Contrast-Enhanced Dual-Source Computed Tomography Angiography
    Brado, Johannes
    Breitbart, Philipp
    Hein, Manuel
    Pache, Gregor
    Schmitt, Ramona
    Hein, Jonas
    Apweiler, Matthias
    Soschynski, Martin
    Schlett, Christopher
    Bamberg, Fabian
    Neumann, Franz-Josef
    Westermann, Dirk
    Krauss, Tobias
    Ruile, Philipp
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [26] Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: Prospective comparison with 2D-TOF MR venography and digital subtraction angiography
    Liang, LX
    Korogi, Y
    Sugahara, T
    Onomichi, M
    Shigematsu, Y
    Yang, DW
    Kitajima, M
    Hiai, Y
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (03) : 481 - 492
  • [27] Magnetic Resonance Coronary Angiography: Comparison between a Gd-BOPTA- and a Gd-DTPA-Enhanced Spoiled Gradient-Echo Sequence and a Non-Contrast-Enhanced Steady-State Free-Precession Sequence
    Nassenstein, K.
    Breuckmann, F.
    Hunold, P.
    Barkhausen, J.
    Schlosser, T.
    ACTA RADIOLOGICA, 2009, 50 (04) : 406 - 410
  • [28] Follow-up of intracranial aneurysms treated by flow diverter: comparison of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MR angiography (CE-MRA) sequences with digital subtraction angiography as the gold standard
    Attali, Jonathan
    Benaissa, Azzedine
    Soize, Sebastien
    Kadziolka, Krzysztof
    Portefaix, Christophe
    Pierot, Laurent
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (01) : 81 - 86
  • [29] Visualization of External Carotid Artery and Its Branches: Non-contrast-Enhanced MR Angiography Using Balanced Steady-State Free-Precession Sequence and a Time-Spatial Labeling Inversion Pulse
    Satogami, Naoe
    Okada, Tomohisa
    Koyama, Takashi
    Gotoh, Kimio
    Kamae, Toshikazu
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 678 - 683