A catalytic multi-pumping flow system for the chemiluminometric determination of metformin

被引:17
|
作者
Marques, KL [1 ]
Santos, JLM [1 ]
Lima, JLFC [1 ]
机构
[1] Univ Porto, Fac Pharm, Requimte Phys Chem Dept, P-4099030 Oporto, Portugal
关键词
multi-pumping; pulsed flow; chemiluminescence; metformin; luminol; copper;
D O I
10.1007/s00216-005-3088-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A multi-pumping flow system for the chemiluminometric determination of the hypoglycaemic drug metformin was implemented. The developed methodology was based on the metformin-induced inhibition ( metformin acts as a Cu( II) scavenger) of the catalytic effect of Cu( II) ions on the chemiluminescent reaction between luminol and hydrogen peroxide. The flow manifold configuration was based on the utilisation of multiple solenoid-actuated micro-pumps that were simultaneously accountable for sample/reagent introduction and reaction zone formation/propulsion, thus resulting in a fully automated, simple and highly selective multi-pumping. flow system. A versatile sample manipulation allowed the establishment of distinct sampling strategies with low reagent consumption. The characteristic pulsed flow ensured an effective sample/ reagent mixing leading to a better and faster reaction zone homogenisation and thus improved analytical signals. Linear calibration plots were obtained for metformin hydrochloride concentrations ranging from 5 to 15 mg L-1 with a relative standard deviation lower than 2.0% ( n= 5). Detection limit was 0.94 mg L-1, and the sampling rate was about 95 determinations per hour. The developed methodology was applied to the analysis of pharmaceutical formulations and the obtained results were in agreement with those furnished by the reference method with relative percentage deviations of lower than 1.5%.
引用
收藏
页码:452 / 457
页数:6
相关论文
共 50 条
  • [21] Spectrophotometric determination of phytic acid in plant extracts using a multi-pumping flow system
    Carneiro, JMT
    Zagatto, EAG
    Santos, JLM
    Lima, JLFC
    ANALYTICA CHIMICA ACTA, 2002, 474 (1-2) : 161 - 166
  • [22] A multi-pumping flow analysis system for β-galactosidase activity assays
    Skoczek, Justyna
    Pokrzywnicka, Marta
    Kubacka, Olga
    Koncki, Robert
    FOOD CHEMISTRY, 2019, 294 : 231 - 237
  • [23] Multi-pumping flow systems: The potential of simplicity
    Santos, Joao L. M.
    Ribeiro, Marta F. T.
    Dias, Ana C. B.
    Lima, Jose L. F. C.
    Zagatto, Elias E. A.
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 21 - 28
  • [24] Multi-pumping flow system for the determination, solid-phase extraction and speciation analysis of iron
    Pons, C
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 2005, 550 (1-2) : 33 - 39
  • [25] Multi-pumping flow system for the determination of boron in eye drops, drinking water and ocean water
    Gonzalez, Pablo
    Sixto, Alexandra
    Knochen, Moises
    TALANTA, 2017, 166 : 399 - 404
  • [26] Multi-pumping flow system for the determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples
    Pons, Carmen
    Toth, Ildiko V.
    Rangel, Antonio O. S. S.
    Forteza, Rafael
    Cerda, Victor
    ANALYTICA CHIMICA ACTA, 2006, 572 (01) : 148 - 154
  • [27] An Automated Multi-Pumping Pulsed Flow System with Spectrophotometric Detection for the Determination of Phosphate in Natural Waters
    Ribeiro, Marta F. T.
    Couto, Cristina M. C. M.
    Conceicao, Pedro M. M.
    Santos, Joao L. M.
    ANALYTICAL LETTERS, 2013, 46 (11) : 1769 - 1778
  • [28] Determination of Glyphosate in Water Samples by Multi-pumping Flow System Coupled to a Liquid Waveguide Capillary Cell
    Aline S. Silva
    Ildikó V. TóTH
    Leonardo Pezza
    Helena R. Pezza
    José L. F. C. Lima
    Analytical Sciences, 2011, 27 : 1031 - 1036
  • [29] Multi-pumping flow systems: an automation tool
    Lima, JLFC
    Santos, JLM
    Dias, ACB
    Ribeiro, MFT
    Zagatto, EAG
    TALANTA, 2004, 64 (05) : 1091 - 1098
  • [30] Determination of glyphosate in water samples by multi-pumping flow system coupled to a liquid waveguide capillary cell
    Instituto de Química, Universidade Estadual Paulista , P. O. Box 355, Araraquara CEP 14801-970, SP, Brazil
    不详
    Anal. Sci., 10 (1031-1036):