Response of MV-connected Doubly-Fed Induction Generator Wind Turbines and CHP-plants to Grid Disturbances

被引:0
|
作者
Karaliolios, P. [1 ]
Slootweg, J. G. [1 ]
Kling, W. L. [1 ]
机构
[1] Eindhoven Univ Technol, Elect Energy Syst Grp, NL-5600 MB Eindhoven, Netherlands
关键词
Decentralized Generation; Fault Ride-Through; Short-Circuit contribution; CHP-plant; Doubly-Fed Induction Generator;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Notwithstanding the positive environmental impact, the increasing penetration of Distributed Generation (DG) units connected to the distribution network raises new topics concerning the expected response of these during outages. Grid disturbances especially at the transmission level can cause the unwanted disconnection of large amounts of DG, leading to undesired power imbalances causing line overloadings and/or voltage and frequency instability. This paper examines how transmission network faults can affect the operation of DG units connected on to the distribution network, how these units currently contribute to the voltage support and what are the consequences of actual and possible Fault Ride-Through (FRT) behaviors.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Selective Compensation of Current Harmonics in Grid-Connected Doubly-Fed Induction Generator based Wind Energy System
    Shapoval, I. A.
    Mykhalskyi, V. M.
    Sobolev, V. M.
    Chopyk, V. V.
    Polishchuk, S. Y.
    2018 IEEE 3RD INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS), 2018, : 214 - 218
  • [42] Investigation of Doubly-Fed Induction Generator Drives Behaviour at Synchronous Operating Point in Wind Turbines
    Bruns, Martin
    Rabelo, Balduino
    Hofmann, Wilfried
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 5549 - 5558
  • [43] Direct power control for doubly-fed induction generator wind turbines with a constant switching frequency
    Zhejiang University, Hangzhou 310027, China
    Dianli Xitong Zidonghue, 2008, 1 (61-65):
  • [44] Repetitive Control of Doubly-Fed Induction Generator For General Distorted Grid Voltage Disturbances Rejection
    Quan, Yu
    Zhang, Jianmin
    Zhao, Chen
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [45] A Novel Grid Synchronization Control of Doubly-fed Induction Generator
    ZHAN Liang-yu
    电力电子技术, 2012, 46 (04) : 38 - 42
  • [46] Analysis of the By-Pass Resistance of an Active Crowbar for Doubly-Fed Induction Generator Based Wind Turbines under Grid Faults
    Zhang, Wei
    Zhou, Peng
    He, Yikang
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2316 - 2321
  • [47] Shorted-Stator Mode Control of Doubly-Fed Induction Generator Connected to a Weak Grid
    Balogun, Adeola
    Ojo, Olorunfemi
    Okafor, Frank
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1847 - 1851
  • [48] An Improved Grid Synchronization Control of Doubly-Fed Induction Generator
    Zhan, Liangyu
    Jin, Xinmin
    Zhang, Lu
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [49] Decoupled control of active and reactive power for a grid-connected doubly-fed induction generator
    Guo, Jiahu
    Cai, Xu
    Gong, Youming
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2620 - 2625
  • [50] Mathematical Modelling of Grid Connected Doubly Fed Induction Generator Based Wind Farm
    Mahalakshmi, R.
    Viknesh, J.
    Thampatty, K. C. Sindhu
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,