Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus

被引:1
|
作者
Gundersen, Kjell Gunnar [1 ]
Potvin, Richard [2 ]
机构
[1] IFocus Oyeklin AS, Sorhauggata 111, N-5527 Haugesund, Norway
[2] Sci Vis, Bend, OR USA
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
sulcus; secondary IOL; AddOn EDOF; EDOF; extended depth of focus; BILATERAL IMPLANTATION; ADD-ON; BAG; PERFORMANCE; ERROR;
D O I
10.2147/OPTH.S366145
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the range of vision, visual function, and quality of vision after implantation of a secondary extended depth of focus intraocular lens (EDOF IOL) implanted in the sulcus. Setting: One clinical practice in Haugesund, Norway. Design: Prospective single arm non-interventional study. Methods: Eligible subjects presenting for surgery, or who had previous successful primary cataract or refractive lens exchange surgery in both eyes were subsequently implanted with the AddOn (R) secondary EDOF IOL in the sulcus. Manifest refraction and visual acuity at distance, intermediate and near were measured 3 months after surgery, along with the monocular defocus curve. Subjects also completed a visual function and a quality of vision questionnaire. Results: The study included 32 eyes of 16 subjects. At 3 months postoperative, the mean refraction spherical equivalent (MRSE) was -0.16 +/- 0.30 D, with a residual cylinder of 0.29 +/- 0.27 D. The mean monocular uncorrected VA was 0.1 logMAR (20/25) or better at all test distances. The monocular defocus curves showed a depth of focus of 2.0 D. For every category except reading fine print, all but one subject (94%) had no difficulty or little difficulty with near tasks. Glare and halos were the most common visual disturbances, with no reports of starbursts. There was no evidence of any intralenticular opacification in any of the eyes, and no evidence of iris chafing/depigmentation. Conclusion: This secondary EDOF IOL provided excellent distance and intermediate vision, and very good near vision to subjects. Subject reported near visual function was also very good and visual disturbances were limited. This lens appears to be a good option for patients who would like to improve their range of vision. Results appear as good or better than those reported for primary EDOF lenses.
引用
收藏
页码:1861 / 1869
页数:9
相关论文
共 50 条
  • [31] A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (02) : 182 - 187
  • [32] Correction: Tolerance to refractive error with a new extended depth of focus intraocular lens
    Daniel A. Black
    Chandra Bala
    Aixa Alarcon
    Srividhya Vilupuru
    Eye, 2025, 39 (1) : 203 - 203
  • [33] Design and Optical Analysis of a Refractive Aspheric Intraocular Lens with Extended Depth of Focus
    Li, Kunqi
    Chen, Xiaoqin
    Bian, Yayan
    Xing, Yuwei
    Li, Xiaolan
    Liu, Dongyu
    Liu, Yongji
    Seeger, Thomas
    OPTICS, 2023, 4 (01): : 146 - 155
  • [34] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Thomas Kohnen
    Myriam Böhm
    Eva Hemkeppler
    Sabrina Schönbrunn
    Nina DeLorenzo
    Kerstin Petermann
    Michael Herzog
    Eye, 2019, 33 : 1556 - 1563
  • [35] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Kohnen, Thomas
    Boehm, Myriam
    Hemkeppler, Eva
    Schoenbrunn, Sabrina
    DeLorenzo, Nina
    Petermann, Kerstin
    Herzog, Michael
    EYE, 2019, 33 (10) : 1556 - 1563
  • [36] Refractive outcomes after bilateral multifocal intraocular lens implantation
    Pineda-Fernández, A
    Jaramillo, J
    Celis, V
    Vargas, J
    DiStacio, M
    Galíndez, A
    Del Valle, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03): : 685 - 688
  • [37] Refractive outcomes after primary intraocular lens implantation in infants
    Ashworth, J. L.
    Maino, A. P.
    Biswas, S.
    Lloyd, I. C.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (05) : 596 - 599
  • [38] Patient Satisfaction and Visual Performance in Patients with Ocular Pathology after Bilateral Implantation of a New Extended Depth of Focus Intraocular Lens
    Rementeria-Capelo, Laureano A.
    Lorente, Pilar
    Carrillo, Virginia
    Sanchez-Pina, Jose M.
    Ruiz-Alcocer, Javier
    Contreras, Ines
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [39] Visual outcome after monocular implantation of extended depth of focus intraocular lens in a patient with iridodialysis: a case report and literature review
    Edward Tran
    Nirmit Shah
    Angela Kyveris
    Toby Yiu Bong Chan
    Journal of Medical Case Reports, 18 (1)
  • [40] The relationship between patient satisfaction and visual and optical outcome after bilateral implantation of an extended depth of focus multifocal intraocular lens
    Mihaltz, Kata
    Szegedi, Stephan
    Steininger, Jolanda
    Vecsei-Marlovits, Pia Veronika
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2022, 2 (01):