Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus

被引:1
|
作者
Gundersen, Kjell Gunnar [1 ]
Potvin, Richard [2 ]
机构
[1] IFocus Oyeklin AS, Sorhauggata 111, N-5527 Haugesund, Norway
[2] Sci Vis, Bend, OR USA
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
sulcus; secondary IOL; AddOn EDOF; EDOF; extended depth of focus; BILATERAL IMPLANTATION; ADD-ON; BAG; PERFORMANCE; ERROR;
D O I
10.2147/OPTH.S366145
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the range of vision, visual function, and quality of vision after implantation of a secondary extended depth of focus intraocular lens (EDOF IOL) implanted in the sulcus. Setting: One clinical practice in Haugesund, Norway. Design: Prospective single arm non-interventional study. Methods: Eligible subjects presenting for surgery, or who had previous successful primary cataract or refractive lens exchange surgery in both eyes were subsequently implanted with the AddOn (R) secondary EDOF IOL in the sulcus. Manifest refraction and visual acuity at distance, intermediate and near were measured 3 months after surgery, along with the monocular defocus curve. Subjects also completed a visual function and a quality of vision questionnaire. Results: The study included 32 eyes of 16 subjects. At 3 months postoperative, the mean refraction spherical equivalent (MRSE) was -0.16 +/- 0.30 D, with a residual cylinder of 0.29 +/- 0.27 D. The mean monocular uncorrected VA was 0.1 logMAR (20/25) or better at all test distances. The monocular defocus curves showed a depth of focus of 2.0 D. For every category except reading fine print, all but one subject (94%) had no difficulty or little difficulty with near tasks. Glare and halos were the most common visual disturbances, with no reports of starbursts. There was no evidence of any intralenticular opacification in any of the eyes, and no evidence of iris chafing/depigmentation. Conclusion: This secondary EDOF IOL provided excellent distance and intermediate vision, and very good near vision to subjects. Subject reported near visual function was also very good and visual disturbances were limited. This lens appears to be a good option for patients who would like to improve their range of vision. Results appear as good or better than those reported for primary EDOF lenses.
引用
收藏
页码:1861 / 1869
页数:9
相关论文
共 50 条
  • [21] Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof® Vivity™ intraocular lens implantation
    Jeon, Sohee
    Choi, Ayoung
    Kwon, Hyunggoo
    PLOS ONE, 2022, 17 (11):
  • [22] Refractive and Visual Outcomes After Bilateral Implantation of a Trifocal Intraocular Lens in a Large Population
    Carreno, Edgardo
    Carreno, Edgardo A.
    Carreno, Rodrigo
    Carreno, Maricarmen
    Lopez, Veronica
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 369 - 376
  • [23] Influence of angle κ on visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens
    Garzon, Nuria
    Garcia-Montero, Maria
    Lopez-Artero, Esther
    Albarran-Diego, Cesar
    Perez-Cambrod, Rafael
    Illarramendi, Igor
    Poyales, Francisco
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 721 - 727
  • [24] Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens
    Mazzini, Cinzia
    CASE REPORTS IN OPHTHALMOLOGY, 2013, 4 (02): : 48 - 56
  • [25] Complications and Visual Outcomes After Secondary Intraocular Lens Implantation in Children REPLY
    Shenoy, Bhamy Hariprasad
    Mittal, Vaibhev
    Gupta, Amit
    Kekunnaya, Ramesh
    Sachdeva, Virender
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) : 1087 - 1088
  • [26] Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular Lens
    Corbett, Dean
    Black, Daniel
    Roberts, Timothy V.
    Cronin, Brendan
    Gunn, David
    Bala, Chandra
    Versace, Patrick
    Tsai, Linda
    Papadatou, Eleni
    Alarcon, Aixa
    Vilupuru, Srividhya
    EYE, 2024, 38 (SUPPL 1) : 9 - 14
  • [27] Clinical outcomes and optical performance of a new segmental refractive extended depth-of-focus intraocular lens
    Amaro, David Rua
    Bertelmann, Eckart
    von Sonnleithner, Christoph
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [28] Visual and clinical outcomes after bilateral implantation of a novel extended depth of focus lens post cataract surgery
    Bansal, Muskaan
    Thakur, Anchal
    Jeshan, Mohammed
    Sachdeva, Kulbhushan
    Malhotra, Chintan
    Gupta, Amit
    Jain, Arun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (09) : 1267 - 1274
  • [29] Visual Performance of Eyes with Residual Refractive Errors after Implantation of an Extended Vision Intraocular Lens
    Rementeria-Capelo, Laureano A. A.
    Contreras, Ines
    Moran, Aida
    Lorente-Hevia, Pilar
    Marinas, Laura
    Ruiz-Alcocer, Javier
    JOURNAL OF OPHTHALMOLOGY, 2023, 2023
  • [30] Visual outcomes and photic phenomena following bilateral extended depth of focus intraocular lens implants
    Sundaram, Aishwarya
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2020, 55 (02): : E50 - E51