Clip marker placement following MR-guided vacuum biopsy of the breast

被引:14
|
作者
Perlet, C
Sittek, H
Reiser, M
Heywang-Köbrunner, SH
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Abt Bildgebende & Intervent Mammadiagnost, D-81675 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Klin Radiol, D-8000 Munich, Germany
来源
RADIOLOGE | 2005年 / 45卷 / 03期
关键词
breast; MRI; biopsy technology; intervention;
D O I
10.1007/s00117-005-1173-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose.The purpose of our study was to determine the placement accuracy, usefulness as a guide for wire localization, and long-term stability of tissue marker clips following MR-guided vacuum-assisted biopsy (VB) of breast lesions. Methods. During a 2-year period, MR-guided VB with an 11-gauge device was performed in 79 lesions. In 26 lesions a marker clip was placed at the biopsy site. Results. In 18 cases, the clip was shown to be closely adjacent to the lesion on postinterventional MR images. In seven cases in which minor bleeding occurred, the clip dislocated (<= 15 mm) in the direction of the needle pathway. In one case dislocation in the dorsal direction (: 5 mm) was observed. In eight cases with a malignant or borderline histology according to the VB, the marker clips served as targets for mammographically guided wire localization. In all of those patients, histology results derived from open surgery confirmed those of VB. Eighteen patients with benign findings according to the VB were followed up 6 months later. Among these cases we found a significant displacement of the marker clip in one case (3 cm). The clip generally caused a round artifact (diameter of 9 2 mm). In two cases it was not possible to determine whether the lesion had been removed completely or was just behind the artifact caused by the clip. Conclusion. Based on our results, clip marker placement following MR-guided vacuum biopsy should be called into question due to the possibility of masking the lesion by a metallic artifact and because of possible dislocation.
引用
收藏
页码:230 / +
页数:6
相关论文
共 50 条
  • [31] A TECHNIQUE FOR MR-GUIDED NEEDLE PLACEMENT
    LUFKIN, R
    TERESI, L
    CHIU, L
    HANAFEE, W
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (01) : 193 - 196
  • [32] LOCALIZATION GRID FOR MR-GUIDED BIOPSY
    WIDDER, DJ
    RADIOLOGY, 1988, 166 (02) : 581 - 581
  • [33] LOCALIZATION GRID FOR MR-GUIDED BIOPSY
    HAJEK, PC
    GYLYSMORIN, VM
    STAVAS, J
    VANSONNENBERG, E
    RADIOLOGY, 1987, 163 (03) : 825 - 826
  • [34] Beware the clip! Breast marker clip damage during vacuum-assisted excision biopsy
    Taylor, Donna B.
    Dessauvagie, Benjamin F.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (01) : 102 - 104
  • [35] Stereotaxic add-on device for MR-guided biopsy of breast lesions
    Doler, W
    Fischer, U
    Metzger, I
    Harder, D
    Grabbe, E
    RADIOLOGY, 1996, 200 (03) : 863 - 864
  • [36] MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience
    Claudio Spick
    Melanie Schernthaner
    Katja Pinker
    Panagiotis Kapetas
    Maria Bernathova
    Stephan H. Polanec
    Hubert Bickel
    Georg J. Wengert
    Margaretha Rudas
    Thomas H. Helbich
    Pascal A. Baltzer
    European Radiology, 2016, 26 : 3908 - 3916
  • [37] MR-guided vacuum-assisted breast biopsy of MRI-only lesions: a single center experience
    Spick, Claudio
    Schernthaner, Melanie
    Pinker, Katja
    Kapetas, Panagiotis
    Bernathova, Maria
    Polanec, Stephan H.
    Bickel, Hubert
    Wengert, Georg J.
    Rudas, Margaretha
    Helbich, Thomas H.
    Baltzer, Pascal A.
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3908 - 3916
  • [38] MR-guided vacuum-assisted breast biopsy with a handheld biopsy system: clinical experience and results in postinterventional MR mammography after 24 h
    E. A. Hauth
    H. J. Jaeger
    J. Lubnau
    S. Maderwald
    F. Otterbach
    R. Kimmig
    M. Forsting
    European Radiology, 2008, 18 : 168 - 176
  • [39] MR-guided vacuum-assisted breast biopsy with a handheld biopsy experience and results system: clinical in postinterventional MR mammography after 24 h
    Hauth, E. A.
    Jaeger, H. J.
    Lubnau, J.
    Maderwald, S.
    Otterbach, F.
    Kimmig, R.
    Forsting, M.
    EUROPEAN RADIOLOGY, 2008, 18 (01) : 168 - 176
  • [40] MR-guided breast biopsy at 3T: diagnostic yield of large core needle biopsy compared with vacuum-assisted biopsy
    Meeuwis, Carla
    Veltman, Jeroen
    van Hall, Hester N.
    Mus, Roel D. M.
    Boetes, Carla
    Barentsz, Jelle O.
    Mann, Ritse M.
    EUROPEAN RADIOLOGY, 2012, 22 (02) : 341 - 349