Clip marker placement following MR-guided vacuum biopsy of the breast

被引:14
|
作者
Perlet, C
Sittek, H
Reiser, M
Heywang-Köbrunner, SH
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Abt Bildgebende & Intervent Mammadiagnost, D-81675 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Klin Radiol, D-8000 Munich, Germany
来源
RADIOLOGE | 2005年 / 45卷 / 03期
关键词
breast; MRI; biopsy technology; intervention;
D O I
10.1007/s00117-005-1173-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose.The purpose of our study was to determine the placement accuracy, usefulness as a guide for wire localization, and long-term stability of tissue marker clips following MR-guided vacuum-assisted biopsy (VB) of breast lesions. Methods. During a 2-year period, MR-guided VB with an 11-gauge device was performed in 79 lesions. In 26 lesions a marker clip was placed at the biopsy site. Results. In 18 cases, the clip was shown to be closely adjacent to the lesion on postinterventional MR images. In seven cases in which minor bleeding occurred, the clip dislocated (<= 15 mm) in the direction of the needle pathway. In one case dislocation in the dorsal direction (: 5 mm) was observed. In eight cases with a malignant or borderline histology according to the VB, the marker clips served as targets for mammographically guided wire localization. In all of those patients, histology results derived from open surgery confirmed those of VB. Eighteen patients with benign findings according to the VB were followed up 6 months later. Among these cases we found a significant displacement of the marker clip in one case (3 cm). The clip generally caused a round artifact (diameter of 9 2 mm). In two cases it was not possible to determine whether the lesion had been removed completely or was just behind the artifact caused by the clip. Conclusion. Based on our results, clip marker placement following MR-guided vacuum biopsy should be called into question due to the possibility of masking the lesion by a metallic artifact and because of possible dislocation.
引用
收藏
页码:230 / +
页数:6
相关论文
共 50 条
  • [21] Accuracy of marker clip placement after Mammotome breast biopsy
    Kruger, BM
    Burrowes, P
    MacGregor, JH
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2002, 53 (03): : 137 - 140
  • [22] European multicenter study on MR-guided vacuum biopsy of the breast: Results of phase I and II
    Perlet, C
    Prat, X
    Sittek, H
    Casselman, I
    Heinig, A
    Heywang-Koebrunner, SH
    RADIOLOGY, 2001, 221 : 378 - 378
  • [23] Multicenter-study on MR-guided breast localisation and vacuum biopsy - First year report
    Heywang-Koebrunner, SH
    Sittek, H
    Prat, X
    Baath, L
    Lamarque, J
    Heinig, A
    RADIOLOGY, 2000, 217 : 493 - 493
  • [24] MR-guided vacuum-assisted breast biopsy: Accuracy of targeting and success in sampling in a model
    Lehman, CD
    Aikawa, T
    RADIOLOGY, 2004, 232 (03) : 911 - 914
  • [25] Diagnostic Performance of MR-guided Vacuum-Assisted Breast Biopsy: 8 Years of Experience
    Ferre, Romuald
    Ianculescu, Victor
    Ciolovan, Laura
    Mathieu, Marie-Christine
    Uzan, Catherine
    Canale, Sandra
    Delaloge, Suzette
    Dromain, Clarisse
    Balleyguier, Corinne
    BREAST JOURNAL, 2016, 22 (01): : 83 - 89
  • [26] Clip placement during sonographically guided breast biopsy -: Reply
    Guenin, MA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) : 1076 - 1077
  • [27] Commercially available titanium clip placement following a sonographically guided core needle biopsy of the breast
    Uematsu, Takayoshi
    BREAST JOURNAL, 2007, 13 (06): : 624 - 626
  • [28] MR-guided percutaneous excisional and incisional biopsy of breast lesions
    Heywang-Köbrunner, SH
    Heinig, A
    Schaumlöffel, U
    Viehweg, P
    Buehmann, J
    Lampe, D
    Spielmann, RP
    EUROPEAN RADIOLOGY, 1999, 9 (08) : 1656 - 1665
  • [29] MR-guided percutaneous excisional and incisional biopsy of breast lesions
    S. H. Heywang-Köbrunner
    A. Heinig
    U. Schaumlöffel
    P. Viehweg
    J. Buchmann
    D. Lampe
    R.-P. Spielmann
    European Radiology, 1999, 9 : 1656 - 1665
  • [30] Clip placement after stereotactic vacuum-assisted breast biopsy
    Liberman, L
    Dershaw, DD
    Morris, EA
    Abramson, AF
    Thornton, CM
    Rosen, PP
    RADIOLOGY, 1997, 205 (02) : 417 - 422