Clip marker placement following MR-guided vacuum biopsy of the breast

被引:14
|
作者
Perlet, C
Sittek, H
Reiser, M
Heywang-Köbrunner, SH
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Abt Bildgebende & Intervent Mammadiagnost, D-81675 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Klin Radiol, D-8000 Munich, Germany
来源
RADIOLOGE | 2005年 / 45卷 / 03期
关键词
breast; MRI; biopsy technology; intervention;
D O I
10.1007/s00117-005-1173-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose.The purpose of our study was to determine the placement accuracy, usefulness as a guide for wire localization, and long-term stability of tissue marker clips following MR-guided vacuum-assisted biopsy (VB) of breast lesions. Methods. During a 2-year period, MR-guided VB with an 11-gauge device was performed in 79 lesions. In 26 lesions a marker clip was placed at the biopsy site. Results. In 18 cases, the clip was shown to be closely adjacent to the lesion on postinterventional MR images. In seven cases in which minor bleeding occurred, the clip dislocated (<= 15 mm) in the direction of the needle pathway. In one case dislocation in the dorsal direction (: 5 mm) was observed. In eight cases with a malignant or borderline histology according to the VB, the marker clips served as targets for mammographically guided wire localization. In all of those patients, histology results derived from open surgery confirmed those of VB. Eighteen patients with benign findings according to the VB were followed up 6 months later. Among these cases we found a significant displacement of the marker clip in one case (3 cm). The clip generally caused a round artifact (diameter of 9 2 mm). In two cases it was not possible to determine whether the lesion had been removed completely or was just behind the artifact caused by the clip. Conclusion. Based on our results, clip marker placement following MR-guided vacuum biopsy should be called into question due to the possibility of masking the lesion by a metallic artifact and because of possible dislocation.
引用
收藏
页码:230 / +
页数:6
相关论文
共 50 条
  • [1] Clipmarkierung nach MRT-gesteuerter Vakuumbiopsie der MammaClip marker placement following MR-guided vacuum biopsy of the breast
    C. Perlet
    H. Sittek
    M. Reiser
    S. H. Heywang-Köbrunner
    Der Radiologe, 2005, 45 : 230 - 236
  • [2] Marker clip placement following directional, vacuum-assisted breast biopsy
    Reynolds, HE
    AMERICAN SURGEON, 1999, 65 (01) : 59 - 60
  • [3] MR-guided breast biopsy
    SH Heywang-Köbrunner
    H Sittek
    X Prat
    L Baath
    Breast Cancer Research, 2 (Suppl 2)
  • [4] MR-guided vacuum assisted breast biopsy with the ATEC® breast biopsy and excision system
    Hauth, E. A.
    Umutlu, L.
    Quinsten, A.
    Kuemmel, S.
    Kimmig, R.
    Forsting, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2008, 68 (09) : 901 - 906
  • [5] MR-guided interventional breast procedures considering vacuum biopsy in particular
    Viehweg, P
    Heinig, A
    Amaya, B
    Alberich, T
    Laniado, M
    Heywang-Köbrunner, SH
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 42 (01) : 32 - 39
  • [6] MR-guided vacuum-assisted breast biopsy: is it an essential technique?
    Mitsuhiro Tozaki
    Norie Yamashiro
    Takako Suzuki
    Naoko Kawano
    Shinji Ozaki
    Naomi Sakamoto
    Satoko Abe
    Tomoko Ogawa
    Nobuhito Katayama
    Yuko Tsunoda
    Eisuke Fukuma
    Breast Cancer, 2009, 16
  • [7] MR-guided vacuum-assisted breast biopsy: is it an essential technique?
    Tozaki, Mitsuhiro
    Yamashiro, Norie
    Suzuki, Takako
    Kawano, Naoko
    Ozaki, Shinji
    Sakamoto, Naomi
    Abe, Satoko
    Ogawa, Tomoko
    Katayama, Nobuhito
    Tsunoda, Yuko
    Fukuma, Eisuke
    BREAST CANCER, 2009, 16 (02) : 121 - 125
  • [8] MR-Guided breast biopsy using an active marker: A phantom study
    Werner, Richard
    Krueger, Sascha
    Winkel, Axel
    Albrecht, Christoph
    Schaeffter, Tobias
    Heller, Martin
    Frahm, Christian
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (01) : 235 - 241
  • [9] Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
    Perlet, C
    Heinig, A
    Prat, X
    Casselman, J
    Baath, L
    Sittek, H
    Stets, C
    Lamarque, J
    Anderson, I
    Schneider, P
    Taourel, P
    Reiser, M
    Heywang-Köbrunner, SH
    EUROPEAN RADIOLOGY, 2002, 12 (06) : 1463 - 1470
  • [10] Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast
    C. Perlet
    A. Heinig
    X. Prat
    J. Casselman
    L. Baath
    H. Sittek
    C. Stets
    J. Lamarque
    I. Anderson
    P. Schneider
    P. Taourel
    M. Reiser
    S. Heywang-Köbrunner
    European Radiology, 2002, 12 : 1463 - 1470