摘要
A laser heterodyne imaging vibrometry is proposed for full-field vibration measurement. The vibration responses are imaged and recorded using a CMOS camera and a digital video recorder. A digital demodulation method based on a cumulative distribution function and autocorrelation is designed to demodulate signals affected by speckle noise. The experimental investigations confirm the viability of the proposed method for vibration measurement. Meanwhile, a comparison with laser Doppler vibrometry is performed to further validate the method. The results prove the proposed vibrometry is an effective and precise option for full-field vibration measurement. (C) 2021 Optical Society of America
引用
收藏
页码:8513 / 8523
页数:11
相关论文
共 50 条
  • [31] An Alternative to LEDs for Full-Field Imaging
    Redding, Brandon
    Ahmadi, Peyman
    Cao, Hui
    PHOTONICS SPECTRA, 2016, 50 (05) : 46 - 49
  • [32] Full-field digital mammographic imaging
    Niklason, LT
    Christian, BT
    Whitman, GJ
    Kopans, DB
    Rougeot, HM
    OpsahlOng, B
    RADIOLOGY, 1996, 201 : 28 - 28
  • [33] Full-Field Digital Holographic Vibrometry for Characterization of High-Speed MEMS
    Razavi, Payam
    Furlong, Cosme
    Trolinger, James D.
    ADVANCEMENT OF OPTICAL METHODS IN EXPERIMENTAL MECHANICS, VOL 3, 2017, : 41 - 47
  • [34] Full-field high-speed laser Doppler imaging system for blood-flow measurements
    Serov, Alexandre
    Lasser, Theo
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS IV, 2006, 6080
  • [35] Effect of frequency difference deviation on full-field heterodyne measurement accuracy
    Wu Zhou
    Zhang Wen-Xi
    Xiang Li-Bin
    Li Yang
    Kong Xin-Xin
    ACTA PHYSICA SINICA, 2018, 67 (02)
  • [36] A high resolution full-field range imaging system for robotic devices
    Carnegie, DA
    Cree, MJ
    Dorrington, AA
    Payne, AD
    Proceedings of the Sixth IASTED International Conference on Robotics and Applications, 2005, : 306 - 311
  • [37] Full-field measurement of the phase retardation for birefringent elements by using common path heterodyne interferometry
    Chen, Yen-Liang
    Su, Der-Chin
    OPTICS AND LASERS IN ENGINEERING, 2009, 47 (3-4) : 484 - 487
  • [38] Composite NDE using full-field pulse-echo ultrasonic propagation imaging system
    Hong, Seung-Chan
    Lee, Jung-Ryul
    Park, Jongwoon
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2016, 2016, 9799
  • [39] EXCIMER LASER PROJECTION LITHOGRAPHY ON A FULL-FIELD SCANNING PROJECTION SYSTEM
    KERTH, RT
    JAIN, K
    LATTA, MR
    IEEE ELECTRON DEVICE LETTERS, 1986, 7 (05) : 299 - 301
  • [40] Full-field optical coherence tomography using a fibre imaging bundle
    Ford, H. D.
    Tatam, R. P.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079